Journal of Veterinary Cardiology兽医心脏病学杂志
Journal of Veterinary Cardiology(英文缩写 J VET CARDIOL),ISSN 1760-2734,eISSN 1875-0834,中文译名:兽医心脏病学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.750 | Q2 |
| 2022 | 1.200 | Q3 |
| 2023 | 1.500 | Q2 |
| 2024 | 1.300 | Q2 |
| 2025 | 1.500 | Q2 |
Journal of Veterinary Cardiology 最新收录文献
-
1. Cone reconstruction for severe tricuspid valve dysplasia in a dog.
PMID:期刊:日期:2026-09-01Tricuspid valve dysplasia (TVD) is a congenital cardiac malformation in dogs characterized by abnormal tricuspid valve morphology, leaflet tethering, impaired leaflet coaptation, and right atrial and ventricular remodelling. This report describes cone reconstruction for severe TVD in a dog. A three-year-and-10-month-old female Labrador retriever presented with a grade IV/VI systolic murmur and exercise intolerance. Echocardiography revealed severe tricuspid regurgitation, a right atrial-to-left atrial ratio of 1.57, malformed and tethered tricuspid valve leaflets, impaired leaflet coaptation, and marked right-sided cardiac enlargement, consistent with severe TVD. Surgery involved tricuspid valve leaflet mobilization, delamination of adherent leaflet tissue and abnormal subvalvular attachments, annular reduction, and reconstruction of the available leaflet tissue into a cone-like valve with leaflet rotation and reattachment. A small, thin, dysplastic portion of the right ventricular free wall was also excluded from the functional right ventricular cavity by longitudinal plication. The dog was discharged on postoperative day seven without other major complications. On postoperative day 294, echocardiography showed a reduction in the colour Doppler tricuspid regurgitant jet, a decrease in the right atrial-to-left atrial ratio to 0.50, and a reduction in right atrial size. Exercise intolerance resolved, although a grade III/VI systolic murmur persisted. Cone reconstruction, adapted from the technique used in human patients with Ebstein's anomaly, may improve tricuspid valve function and clinical signs in selected dogs with severe TVD. However, its indications, reproducibility, and long-term durability in dogs remain unestablished. Further studies are needed to evaluate patient selection, long-term benefits, and potential complications.
-
2. Corrigendum to "Evidence-based medical therapy for mitral regurgitation in dogs" [J Vet Cardiol (2026) 10.1016/j.jvc.2026.04.006].
PMID:期刊:日期:2026-08-27该文献暂无摘要。
-
3. Use of a novel integrated dilator-needle system for trans-septal puncture in three dogs undergoing left atrial decompression.
PMID:期刊:日期:2026-08-22Left atrial decompression (LADEC) is an emerging palliative intervention for dogs with advanced left-sided congestive heart failure. Trans-septal puncture is a critical step of this procedure and is traditionally performed using Brockenbrough-style needles with multiple device exchanges. A novel integrated dilator-needle system (FlexCath Cross™, Medtronic) has been developed in human cardiology to allow a zero-exchange approach to trans-septal puncture; however, its use in veterinary patients has not previously been described. This report describes the technical feasibility of using this integrated system for trans-septal access in three dogs undergoing LADEC for congestive heart failure secondary to myxomatous mitral valve disease. In three cases, trans-septal access was successfully achieved using the integrated dilator-needle system, allowing completion of the planned LADEC procedure. No major device-related complications were observed. These cases demonstrate the feasibility of this alternative trans-septal access technique in selected canine patients.
-
4. Evaluation of the mitral-aortic velocity time integral ratio for severity assessment in dogs with myxomatous mitral valve disease.
PMID:期刊:日期:2026-08-22In dogs, myxomatous mitral valve disease is the most commonly acquired cardiac disorder. Quantitative assessment of mitral regurgitation (MR), particularly regurgitant volume normalized to body weight (RVol/kg), remains challenging. A Doppler-derived mitral-to-aortic velocity time integral (VTI) ratio (calculated as mitral inflow VTI) divided by left ventricular outflow tract VTI]) has been proposed in humans to stratify MR severity. This study evaluated its association with MR severity, American College of Veterinary Internal Medicine stage, and congestive heart failure (CHF). We evaluated 167 dogs with myxomatous mitral valve disease and 21 controls. Echocardiography included mitral inflow VTI, left ventricular outflow tract VTI, and RVol/kg. Repeatability was assessed using intraclass correlation coefficients. Receiver operating characteristic analysis was used to evaluate performance for detecting CHF and severe MR defined by a regurgitant fraction (RF) ≥50%. The mitral-to-aortic VTI ratio increased with stage (P<0.001) and correlated with RVol/kg and RF (r=0.75 each; P<0.001), with high repeatability (intraclass correlation coefficient >0.90). Multivariable regression identified early diastolic transmitral velocity (E), left atrium-to-aorta ratio, and RVol/kg as independent determinants of the mitral-to-aortic VTI ratio. Logistic regression to detect CHF (current and past) showed the association between the mitral-to-aortic VTI ratio and CHF. In the receiver operating characteristic curve analysis, the mitral-to-aortic VTI ratio showed the highest accuracy for identifying an RF ≥ 50% (area under the curve=0.89). Few dogs were in stage C/D. The mitral-to-aortic VTI ratio is a reproducible Doppler index associated with MR severity and American College of Veterinary Internal Medicine stage and may help indicate clinically relevant RF thresholds.
-
5. Predominant mitral valve morphology in dogs at different stages of myxomatous mitral valve disease: toward a standardized nomenclature.
PMID:期刊:日期:2026-08-20Myxomatous mitral valve disease (MMVD) is the most common heart disease in dogs. Echocardiographic markers of cardiac remodeling are used to assess disease severity, but morphological features of the mitral valve are not systematically considered. Conversely, standardized morphological classification schemes are established in human cardiology and are integral to prognosis and therapeutic planning. Our objective was to adapt and apply a mitral valve morphological classification scheme to canine MMVD across various stages. A total of 1108 dogs weighing 1-15 kg with an echocardiographic diagnosis of MMVD (American College of Veterinary Internal Medicine stage B1 = 595; B2 = 314; C/D = 199) were included in the study. Echocardiographic studies were retrospectively reviewed. Leaflet involvement was identified using right parasternal and left apical views and classified as billow, prolapse, isolated flail, or prolapse with flail based on established morphologic descriptions by Barlow and principles of leaflet motion derived from the Carpentier classification. Anterior leaflet involvement predominated all stages, though bileaflet involvement increased in stage C/D. Billow morphology decreased significantly across stages (B1: 79%; B2: 17%; C/D: 5%; P<0.001). Prolapse and isolated flail were significantly more common in stages B2 and C/D than in stage B1 (P<0.001). Prolapse with flail increased progressively from stage B1 (5%) to B2 (25%) to C/D (56%) (P<0.001). This was a retrospective, single-center study with no longitudinal follow-up. Advanced imaging modalities were not evaluated. Mitral valve morphology in dogs with MMVD varies systematically with disease stage, and adoption of a standardized morphological classification scheme will align veterinary cardiology with established human frameworks.
-
6. Multicenter transvenous pacemaker implantation in 595 dogs: complications and survival rates.
PMID:期刊:日期:2026-08-10Transvenous pacemakers are routinely used for pathologic bradyarrhythmias including third-degree atrioventricular block (3AVB), sick sinus syndrome (SSS), high-grade second-degree atrioventricular block (2AVB), and atrial standstill (AS). This study reports the multi-institutional complications and survival rates in a large cohort of dogs. A retrospective analysis of outcomes and complications in dogs that underwent transvenous pacemaker implantation between January 2000 and December 2016 at four academic institutions was conducted. In total, 595 dogs were identified (221 males and 374 females) with a median age of 10.1 years (range: 0.3-17.0 years). Presenting arrhythmias included 3AVB (54.5%), SSS (24.4%), high-grade 2AVB (16.1%), and AS (4.0%). Major complications occurred in 17.5% (104/595) of cases including lead dislodgement (n = 39), infection (n = 24), thrombus formation (n = 19), ventricular fibrillation (n = 8), cardiac arrest (n = 6), cardiac perforation (n = 5), and iatrogenic tricuspid stenosis (n = 3). Ventricular lead dislodgement in AS (20%) occurred more frequently than SSS (1.4%; P=0.002), and 80% of the ventricular leads that dislodged in dogs with AS were passive leads. Procedural mortality rate was 0.8% (5/595). Median survival time was 2.8 years (2AVB, 2.9 years; 3AVB, 2.9 years; AS, 3.3 years; SSS, 2.5 years). Cardiac mortality occurred in 60.0% of AS cases compared to 2AVB (25.0%), 3AVB (21.9%), and SSS (16.9%). Limitations of this study included the retrospective nature of the project with some loss to follow-up. Pacemakers have a low procedural mortality rate, and overall, complications were minimal. Type of lead and underlying disease process may impact the risk of lead dislodgement. Dogs with AS are more likely to die from cardiac-related disease.
-
7. Clinical utility of shear wave speed and dispersion slope measured by shear wave elastography for the assessment of hepatic congestion in dogs with cardiac disease.
PMID:期刊:日期:2026-08-10Right-sided heart failure (RHF) elevates central venous pressure, causing hepatic congestion. Two-dimensional shear wave elastography (2D-SWE) measures shear wave speed (SWS) and dispersion slope (DS), reflecting tissue viscoelasticity and viscosity. The aim was to investigate associations between hepatic SWS and DS and RHF in dogs and evaluate clinical utility. One hundred client-owned dogs with cardiac disease were prospectively classified into RHF (n = 27) and non-RHF (n = 73) groups based on ascites. Hepatic SWS and DS were measured using 2D-SWE. Congestion and cardiac function were assessed via caudal vena cava short-to-long diameter ratio (CVC SD/LD), right atrial area index (RAA index) and left ventricular outflow tract velocity-time integral (LVOT-VTI). Associations between elastography and echocardiographic variables were analysed, and diagnostic performance for RHF was evaluated. Both SWS and DS were significantly higher in RHF dogs (SWS: 1.79 [1.63-2.38]; DS: 16.40 [15.55-19.83]) than non-RHF dogs (SWS: 1.31 [1.25-1.37]; DS: 12.5 [11.0-13.5]; P<0.001) and were moderately correlated with CVC SD/LD, RAA index and LVOT-VTI. Receiver operating characteristic analysis showed DS had the highest area under the curve. Multiple regression analysis indicated SWS was associated with CVC SD/LD and LVOT-VTI, while DS was associated with CVC SD/LD and RAA index. It is a single-centre study without histopathologic confirmation. Hepatic SWS and DS measured are promising non-invasive markers for RHF in dogs. In particular, DS is more specific for hepatic congestion, while SWS reflects both congestion and low cardiac output-related changes.
-
8. Implantation of a LUX-Dx insertable cardiac monitor enables remote heart rhythm monitoring in dogs and cats.
PMID:期刊:日期:2026-07-29Remote long-term rhythm monitoring enables arrhythmia diagnosis and treatment evaluation without in-clinic visits. This prospective case series evaluated the safety, feasibility, and clinical utility of the insertable cardiac monitor LUX-Dx™ and LUX-Dx II/II+™ in dogs and cats. Patients were divided into two groups. The diagnostic group included patients with unexplained intermittent clinical signs potentially caused by arrhythmia. The therapeutic group included patients with known arrhythmias requiring assessment of arrhythmia burden and treatment efficacy. Data were analyzed using the LATITUDE Clarity platform. Electrocardiography strips and tachograms were recorded during tachycardia, during bradycardia, or when triggered by owners. The device continuously registered mean heart rates. The device was implanted in 15 dogs and three cats with a 100% success rate and no complications. All procedures were performed under local anesthesia without sedation or general anesthesia. One-lead electrocardiography tracings were sufficient for rhythm interpretation, and remote monitoring and programming were successful in all patients. Clinically useful information contributed to rhythm diagnosis in 8 of 10 diagnostic patients and supported treatment decisions in all therapeutic patients, although changes in arrhythmia burden were not interpreted as proof of clinical benefit or improved prognosis. In two diagnostic cases, the absence of symptom recurrence with normal rhythm data limited conclusions. Occasional sensing artifacts and misclassification of atrial arrhythmias occurred but were manageable through remote reprogramming. The LUX-Dx™ and LUX-Dx II/II+™ insertable cardiac monitors enable implantation without general anesthesia and remote monitoring in dogs and cats, providing clinically relevant rhythm data.
-
9. Three radiographic methods for assessing left atrial enlargement in dogs: diagnostic performance and correlation with qualitative features.
PMID:期刊:日期:2026-07-29Left atrial (LA) enlargement is a critical indicator of cardiac disease progression in dogs. This study compared the diagnostic accuracy of vertebral heart size (VHS), vertebral left atrial size (VLAS), and radiographic left atrial dimension (RLAD) in detecting ≥moderate LA enlargement using an ordinal echocardiographic reference standard and investigated their correlations with qualitative radiographic features. This retrospective study included 177 dogs. Quantitative radiographic measurements (VHS, VLAS, and RLAD) and qualitative radiographic features (caudodorsal cardiac margin, left auricular bulge, and double wall sign) were evaluated. Left atrial size was classified using established left atrial-to-aortic root ratio (LA:Ao) thresholds (normal <1.6; mild 1.6-1.9; moderate 1.9-2.3; severe ≥2.3). Analyses focused on distinguishing ≥moderate LA enlargement using receiver operating characteristic analysis. Correlations with qualitative features were examined using Spearman correlation. All radiographic measurements showed fair positive correlations with LA:Ao. For detection of ≥moderate LA enlargement, LA-specific measurements demonstrated good diagnostic performance than the fair diagnostic performance of VHS. Optimal cutoffs were VHS ≥10.9, VLAS ≥2.5, and RLAD ≥2.1. Both VLAS and RLAD correlated more strongly with caudodorsal cardiac margin morphology than did VHS. The RLAD was unmeasurable in 39.8% of cases, and demonstrated lower interobserver agreement than VHS and VLAS. Measurements specific to the LA (VLAS and RLAD) demonstrated improved diagnostic performance for detecting ≥moderate LA enlargement and correlated more strongly with wedge-shaped caudodorsal margin than VHS. Vertebral left atrial size provided the optimal balance of performance, feasibility, and reliability for clinical use.
-
10. Breed screening for myxomatous mitral valve disease in dogs.
PMID:期刊:日期:2026-07-21Myxomatous mitral valve disease contributes to cardiac morbidity and mortality in dogs worldwide. It is the most common heart disease in dogs. The exact cause of myxomatous mitral valve disease is still unknown but it is described as heritable in some dog breeds. The present literature review presents an overview of myxomatous mitral valve disease breeding screening methods and ongoing screening programs in dogs.