JOURNAL OF ADHESIVE DENTISTRY牙科粘接杂志
JOURNAL OF ADHESIVE DENTISTRY(英文缩写 J ADHES DENT),ISSN 1461-5185,eISSN 1757-9988,中文译名:牙科粘接杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.309 | Q1 |
| 2022 | 3.300 | Q2 |
| 2023 | 2.500 | Q2 |
| 2024 | 2.700 | Q1 |
| 2025 | 2.700 | Q2 |
JOURNAL OF ADHESIVE DENTISTRY 最新收录文献
-
1. EFCD Expert Non-Consensus on Material and Technique Use for Direct Class II Composites With Guidance on Restoring Complex Cavities.
1. EFCD专家关于直接II类复合树脂材料和技术使用的非共识意见及复杂窝洞修复指导PMID:日期:2026-10-02There is confusion over the indications, techniques, and material choices for placing direct class II composite restorations among general dentists. This paper synthesizes new data on the general frequency of use of materials and techniques by experts, with a previous related paper that explored if and how experts restored specific class II cavities with varying complexities. It aimed to see if consensus on technique and material use when restoring class II cavities with composite could be pursued. These findings are used to inform an overview of various techniques and provide guidance on the management of more complex class II cavities. An international expert group (n = 9) developed an e-questionnaire. The first part of the questionnaire, reported here, covered the general frequency of material and technique use during cavity preparation, control of the operating field, soft tissue management, matrix selection, stabilization and peripheral seal, tooth separation, composite materials, application techniques, light curing, finishing, and polishing. It was distributed to 67 international clinicians with expertise in placing direct composite restorations (September 2024). Response rate was 82%, with 95% of responders completing the first part of the survey. There was a wide variation in frequency of use of a broad variety of materials and techniques. International experts used a wide variety of materials and techniques for restoration of class II cavities with direct composite. Consensus was therefore not pursued. There are many potential techniques which can offer pragmatic solutions to directly restore complex class II cavities that are not beyond general practitioners.
-
2. Debonding of Clear Aligner Attachments With Fluorescence-Aided Identification Technique (FIT): An In Vitro Study.
PMID:日期:2026-09-22The aim of this in vitro study was to investigate whether removing fluorescent clear aligner attachments under UV light improves the efficiency of attachment removal and reduces enamel loss and composite residue. Clear aligner attachments were bonded to bovine teeth using fluorescent-modified composite (AlignerFlow LC, VOCO, Germany); 20 models were prepared. In a split-mouth design, attachments were removed either using a fluorescence-aided identification technique (FIT) under UV light, or with standard white light (non-FIT). Removal time was recorded for each attachment. Intraoral surface and optical coherence tomography (OCT) scans (T0, T1) were analyzed to quantify enamel loss and composite residue using Avizo Software, while OCT scans were assessed using a dichotomous scale for enamel loss and a four-point scale for composite residue. Although there is a trend toward faster attachment removal with FIT, measurements of removal time did not differ significantly between the groups due to high inter-individual variability. Volumetric analysis revealed a significant reduction in composite residue with FIT, while no significant differences in enamel loss were detected between the groups. OCT measurements revealed no significant differences between groups, as composite residue and enamel loss occurred on a microscopic scale in most of the specimens, regardless of the debonding method. While neither debonding time nor enamel loss were affected, FIT significantly reduced residual composite after attachment removal, suggesting that FIT may contribute to more standardized clinical outcomes. Future in vivo studies with larger sample sizes, multiple operators, and different adhesive systems are needed to validate these findings.
-
3. Influence of Tea-Induced Discoloration and Whitening Protocols on the Optical and Surface Properties of Resin Composites: An In Vitro Study.
PMID:日期:2026-09-11Resin composites are susceptible to extrinsic discoloration and surface alterations from beverages such as tea, as well as subsequent whitening treatments. This study aimed to evaluate the color stability (ΔE00) and surface roughness (Ra) of four resin composites after exposure to tea and whitening using either a mouthwash or a toothpaste. Eighty standardized A1-shade discs were fabricated from Filtek Z350 XT (FZ), Herculite Classic (HC), G-ænial Anterior (G), and Asteria (A) (n = 20/group). Specimens were polished, stored in distilled water for 24 h, and baseline measurements were recorded (T0). All samples were immersed in freshly prepared tea for 6 days (T1) and then randomized into two whitening groups: immersion in Listerine Total Care mouthwash (MW) or brushing with a Colgate Optic White slurry (TP) for 6 days (T2a-T2b). Color was measured using a spectrophotometer, and Ra was measured using a profilometer. Data were analyzed using two-way repeated-measures ANOVA, Tukey post hoc tests, and partial eta-squared effect sizes (α = 0.05). All composites exhibited clinically unacceptable discoloration according to the contemporary CIEDE2000 acceptability thresholds (ΔE00 > 1.8), with HC and A reaching the extremely unacceptable category. Whitening resulted in partial color recovery, with MW outperforming TP (p 0.01). Surface roughness increased following whitening, especially in TP (ΔRa = 0.093 ± 0.024 µm). Large effect sizes were observed for both material and time factors. Tea staining significantly affected the color stability and surface roughness of all composite materials. FZ demonstrated the highest color stability, whereas HC showed the greatest discoloration and surface roughness. Whitening procedures partially reversed discoloration but did not restore baseline values. Overall, composites with finer filler structures exhibited better optical and surface properties compared with conventional hybrid composites.
-
4. Influence of Radiotherapy Timing on Sealer-Dentin Adhesion: A Confocal Microscopy and Push-Out Bond Strength Study.
PMID:日期:2026-08-31The purpose of this study was to evaluate the influence of radiotherapy timing on the dentinal tubule penetration and push-out bond strength of an epoxy resin-based sealer (AH Plus) and a bioceramic sealer (BioRoot RCS). In total, 180 single-rooted sound human mandibular premolars were used and allocated to three main groups with different radiotherapy timings: Control (no irradiation), Before RT (irradiation prior to root canal obturation), and After RT (irradiation after root canal obturation). Subsequently, each group was subdivided into different sealer types: AH Plus and BioRoot RCS. For the Before RT and After RT groups, a cumulative dose of 60 Gy (6 weeks, 2 Gy per day, 5 days per week) was delivered. The dentinal tubule penetration depth was assessed using confocal laser scanning microscopy (n = 15), and the push-out bond strength was measured using a universal testing machine (n = 15). The data were analyzed using three-way ANOVA and Bonferroni tests (p 0.05). In the coronal thirds, the After RT group showed significantly lower tubule penetration and bond strength compared with the Control group for both sealers. In the apical thirds, BioRoot RCS was predominantly affected. The After RT group also showed significantly lower bond strength and tubule penetration than the Before RT group. These results were confirmed by the higher frequency of adhesive failures in the After RT group compared to the others. Finally, in the coronal thirds, AH Plus exhibited significantly higher bond strength than BioRoot RCS despite having lower dentinal tubule penetration. Radiotherapy timing significantly influenced sealer-dentin adhesion, varying by root canal levels and material types. Radiotherapy applied after obturation adversely affected the sealer-dentin interaction, resulting in reduced tubule penetration and bond strength, especially for BioRoot RCS.
-
5. The Effect of Different Types of Adhesive Systems on Marginal Integrity of Class II Resin Composite Restoration.
PMID:日期:2026-08-21To evaluate the marginal integrity of cervical margin relocation (CMR) or deep margin elevation (DME) restorations using a universal adhesive in etch-and-rinse and self-etch modes, compared to gold-standard systems after 6-month water aging. Standardized mesial and distal Class II cavities were prepared in 32 human maxillary premolars. Specimens were assigned to four groups according to adhesive systems and modes: OFL (OptiBond FL), CSE (Clearfil SE Bond), UER (Single Bond Universal; etch-and-rinse), and USE (Single Bond Universal; self-etch) (n = 16 per group). After DME/CMR and final restoration, specimens were stored in 37°C distilled water for 6 months. Marginal integrity was assessed qualitatively via micro-CT by two calibrated observers and quantitatively via 0.5% methylene blue dye. Data were analyzed using weighted kappa coefficient, Wilcoxon signed-rank test, two-way repeated measures analysis of variance (ANOVA), and one-way ANOVA with Games-Howell post-hoc tests (α = 0.05). Micro-CT showed high inter-examiner reliability (κ = 0.84) and stable interfacial adaptation across groups post-aging. However, dye penetration revealed that adhesive mode significantly affected microleakage (p 0.05), while proximal box concavity geometry had no significant effect (p > 0.05). The USE group exhibited the lowest mean microleakage (0.94 ± 0.62 mm), showing no significant differences from OFL and CSE. The UER group showed the highest mean microleakage (1.48 ± 0.09 mm), which was significantly higher than the USE group (p 0.05). Within the limitations of this study, the self-etch application of universal adhesives provided superior durability of marginal seals for DME compared to the etch-and-rinse mode. Optimizing matrix application also minimized the influence of concavity geometry.
-
6. Effect of Etching Protocols on the Bonding Performance of a HEMA-Free Two-Step Universal Adhesive to Caries-Affected Dentin.
PMID:日期:2026-08-18To assess the bonding performance of a two-step universal adhesive applied in etch-and-rinse and self-etch protocols to caries-affected dentin. Mid-coronal dentin surfaces were obtained from extracted human molars and assigned to either sound or caries-affected dentin groups. Specimens were randomly distributed into 12 subgroups (n = 10) based on adhesive type (G2-Bond Universal, Gluma Bond Universal, Clearfil S3 Bond Universal), bonding protocol (self-etch or etch-and-rinse), and evaluation period (24 h or aging). Resin composite blocks were fabricated and subjected to shear bond strength testing after 24 h or 10,000 thermocycles. Fourier-transform infrared spectroscopy was employed to measure the degree of conversion of each adhesive. Statistical analyses included ANOVA, Weibull analysis, and Kruskal-Wallis tests (α = 0.05). Adhesive type and bonding protocol significantly influenced bond strength (p 0.001), whereas substrate condition and thermocycling had no significant impact (p > 0.05). After aging, Clearfil S3 Bond Universal in the self-etch protocol presented considerably lower bond strength to caries-affected dentin compared with G2-Bond Universal and Gluma Bond Universal, with no significant difference between the latter two. After aging, Gluma Bond Universal and G2-Bond Universal revealed significantly greater bond strength to caries-affected dentin when applied in the self-etch protocol than in the etch-and-rinse protocol. No significant differences were detected among adhesives when the etch-and-rinse protocol was used, regardless of testing time and substrate. Phosphoric acid pre-etching negatively affected the bonding performance of Gluma Bond Universal and G2-Bond Universal to caries-affected dentin.
-
7. Influence of Tooth Whitening After Resin Infiltration on the Shear Bond Strength of Orthodontic Brackets.
PMID:日期:2026-08-05To determine the influence of different bleaching methods on the shear bond strength (SBS) of orthodontic brackets bonded to resin-infiltrated (Icon, DMG) extracted human enamel. 64 extracted wisdom teeth were randomized into four groups (n = 16): 1. (-)control (no treatment), 2. (+)control (RI), 3. RI followed by 25% H2O2 (IOB) and 4. RI followed by 10% carbamide peroxide bleaching (HB). After a standardized demineralization protocol, RI and bleaching were performed according to the manufacturer's instructions prior to storage for 14 days. Brackets (Mini Diamond Twin, Ormco) were bonded buccally and lingually (Transbond XT, 3M). SBS values (MPa, traverse speed 0.5 mm/min, Zwick Roell) and the Adhesive Remnant Index (ARI) were determined on the buccal side. Following 5000 thermal cycles (5-55°C; RC 20 CS Lauda), SBS and ARI values for the lingual brackets were determined analogously. Data were analyzed with mixed ANOVA and Kruskal-Wallis and Wilcoxon tests at a 0.05 significance level. Differences in SBS were observed among groups (F(3, 64) = 8.01, P 0.001). HB exhibited the lowest SBS values (14.99 ± 6.42 MPa; 10.84 ± 3.61 MPa), differing significantly from the negative control (P = 0.041; P = 0.002 after thermocycling). No significant differences were noted between IOB and HB. Thermocycling reduced SBS values across all groups (F(3, 64) = 25.83, P 0.001). RI followed by bleaching negatively impacts bracket bonding strength, with a significant reduction observed after home bleaching, while in-office bleaching showed no such effect.
-
8. Operator Experience Does Not Affect the Reliability of Universal Adhesives' Bond Strength; Adhesive Type Does.
8. 操作员经验不影响通用胶粘剂粘合强度的可靠性;粘合剂类型为PMID:日期:2026-06-23[中文摘要] 探讨操作者经验、牙本质湿度状态(DMC)及粘接剂类型对剪切粘接强度的影响,并评估粘接剂在这些条件下的性能一致性,以证明其临床可靠性。将600个健康牙本质表面按操作者随机分组,由5名具有至少10年经验的牙医(n=300/5名牙医)和5名无牙科经验的一年级牙科学生(n=300/5名学生)进行操作。每位操作者在接受主要研究者(PI)关于制造商推荐应用技术的示范前后,分别在湿性、微湿和干燥牙本质表面上应用通用型粘接剂(UA)(Adhese Universal,Ivoclar)和酸蚀-冲洗型粘接剂(ERA)(OptiBond FL,Kerr)(n=60/粘接剂类型)(n=5/DMC)。DMC由PI在操作者应用粘接剂前制备。PI应用复合树脂修复体(Tetric EvoCeram Bulk Fill,Ivoclar)并光照聚合20秒。试样在37°C、100%湿度条件下储存24小时后进行剪切粘接强度(SBS)测试。采用箱线图、Log Worth和Tukey HSD进行统计分析。牙医组ERA的中位SBS为17.79 MPa,四分位距(IQR)为19.61,而学生组中位数较低,为13.52 MPa,IQR为15.81。UA在SBS方面表现出一致性,并降低了不同操作者间的变异性,牙医组和学生组的中位SBS分别为25.53 MPa和24.96 MPa,IQR较窄,分别为10.6和7.3。UA的SBS显著高于ERA(P 0.001)。UA的SBS比ERA高7.38 MPa ± 0.89。虽然UA的SBS未观察到操作者间差异,但牙医组使用ERA的SBS比学生组高1.65 MPa ± 0.73。干燥和微湿牙本质表面条件下的SBS值高于湿性表面(分别为P 0.001和P 0.002),而微湿与干燥表面之间未观察到显著差异。所测试的UA无论操作者和DMC如何均提供了可靠的结果。
[英文摘要] To determine the influence of operators' experience, dentin moisture condition (DMC), and adhesive type on shear bond strength, and evaluate the consistency of adhesive performance under these conditions to demonstrate clinical reliability. Six hundred sound dentin surfaces were randomly divided by five dentists with at least 10 years of experience (n = 300/5 dentists) and five first-year dental students without dental experience (n = 300/5 students). Each operator applied universal (UA) (Adhese Universal, Ivoclar) and etch-and-rinse (ERA) (OptiBond FL, Kerr) adhesives (n = 60/adhesive type) before and after receiving demonstration on the manufacturers' recommended application techniques by the principal investigator (PI), on wet, moist, and dry dentin surfaces (n = 5/DMC). DMCs were obtained by the PI before the operators applied the adhesives. The PI applied composite restorations (Tetric EvoCeram Bulk Fill, Ivoclar) and polymerized for 20 s. Shear bond strength (SBS) test was conducted after 24 h storage at 37°C, in 100% humidity. Boxplot, Log Worth, and Tukey HSD were used for statistics. The median SBS of ERA obtained by dentists was 17.79 MPa with an interquartile range (IQR) of 19.61, while students showed a lower median of 13.52 MPa with IQR of 15.81. The UA showed consistency in SBS and reduced variability across operators with median SBS by dentists and students (25.53 MPa and 24.96 MPa, respectively), with narrower IQRs of 10.6 and 7.3, respectively. SBS of UA was significantly higher than ERA (P 0.001). UA obtained 7.38 MPa ± 0.89 greater SBS than ERA. While no difference in SBS by operator was observed for UA, dentists obtained 1.65 MPa ± 0.73 greater SBS than students with ERA. Dry and moist dentin surface conditions yielded higher SBS values compared to wet surfaces (P 0.001 and P 0.002, respectively), with no significant differences observed between moist and dry surfaces. The tested UA provided reliable outcomes regardless of operator and DMC.
-
9. Experts' Willingness to Restore With Direct Composite: Complexity, Cuspal Coverage, and Techniques.
PMID:日期:2026-06-04Minimal evidence exists on how class II cavity complexity influences direct restoration provision or if complexifying factors influence the use of techniques and materials. This study aimed to explore: (1) experts' willingness to restore a variety of specific presentations of class II cavities with direct composite restorations; (2) the influence of cavity characteristics on this and the provision of cuspal coverage; and (3) how varying cavity presentations affected technique and material use. An e-questionnaire developed by international experts was distributed to 67 experts on direct composite restoration. The questionnaire section reported here presented vignettes of varying class II cavities, coded by potential complexifying factors. Respondents were asked if they would restore them with a direct composite. If so, it then asked what specific materials and techniques would be used. Regression analyses were performed. Vignette response rate was 78%. There was a large variation in willingness to restore varying class II cavity presentations with direct composite. This was significantly influenced by the presence of large inter-proximal 'bridging' gaps, root fillings, broad boxes, ≥ 3 cavity surfaces involved and deep sub-gingival margins. When present, these complexifying characteristics affected material and technique use. Those willing to restore more complex cavities were more likely to use more curved circumferential bands and less likely to use a rubber dam, among other factors. Cavity complexity affects experts' willingness to place direct composite restorations. The willingness to use a variety of techniques was associated with a greater readiness to restore more complex class II cavities with direct composite.
-
10. Effect of Different Specimen Preparation Methods on Dentin Shear Bond Strength: Polyethylene Tubes vs Jig System.
PMID:日期:2026-06-04This study evaluated the influence of different specimen preparation methods on the shear bond strength (SBS) of a universal adhesive to dentin, with the aim of identifying a more standardized and reliable protocol for SBS testing. Thirty-three extracted molars were used to obtain 66 dentin surfaces. After surface preparation with 600-grit silicon carbide paper, specimens were randomly assigned to three groups (n = 22) according to the specimen preparation technique: tube-removed (polyethylene tubes removed before testing), tube-retained (tubes left in place during testing), and jig-based (Ultradent jig system, South Jordan, UT, USA). SBS testing was performed using a universal testing machine at 1 mm/min. Failure modes were analyzed under a stereomicroscope and representative specimens were examined by scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA and Tamhane's T2 post-hoc test (α = 0.05). Significant differences were found among the groups (P 0.001). The highest mean SBS values were obtained in the jig-based group, followed by the tube-removed and tube-retained groups. Adhesive failure was predominant across all groups, with 100% adhesive failures observed in the jig-based group. SEM analysis revealed a more clearly delineated bonding interface in the jig-based group, while tube-based groups exhibited minor polyethylene residues. These findings indicate that the specimen preparation method plays a critical role in the reliability and interpretation of SBS testing outcomes. The jig-based approach may provide more consistent and reproducible SBS results compared to tube-based methods, highlighting the importance of standardized specimen fabrication in adhesive dentistry research.