操作员经验不影响通用胶粘剂粘合强度的可靠性;粘合剂类型为

Operator Experience Does Not Affect the Reliability of Universal Adhesives' Bond Strength; Adhesive Type Does.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

探讨操作者经验、牙本质湿度状态(DMC)及粘接剂类型对剪切粘接强度的影响,并评估粘接剂在这些条件下的性能一致性,以证明其临床可靠性。将600个健康牙本质表面按操作者随机分组,由5名具有至少10年经验的牙医(n=300/5名牙医)和5名无牙科经验的一年级牙科学生(n=300/5名学生)进行操作。每位操作者在接受主要研究者(PI)关于制造商推荐应用技术的示范前后,分别在湿性、微湿和干燥牙本质表面上应用通用型粘接剂(UA)(Adhese Universal,Ivoclar)和酸蚀-冲洗型粘接剂(ERA)(OptiBond FL,Kerr)(n=60/粘接剂类型)(n=5/DMC)。DMC由PI在操作者应用粘接剂前制备。PI应用复合树脂修复体(Tetric EvoCeram Bulk Fill,Ivoclar)并光照聚合20秒。试样在37°C、100%湿度条件下储存24小时后进行剪切粘接强度(SBS)测试。采用箱线图、Log Worth和Tukey HSD进行统计分析。牙医组ERA的中位SBS为17.79 MPa,四分位距(IQR)为19.61,而学生组中位数较低,为13.52 MPa,IQR为15.81。UA在SBS方面表现出一致性,并降低了不同操作者间的变异性,牙医组和学生组的中位SBS分别为25.53 MPa和24.96 MPa,IQR较窄,分别为10.6和7.3。UA的SBS显著高于ERA(P 0.001)。UA的SBS比ERA高7.38 MPa ± 0.89。虽然UA的SBS未观察到操作者间差异,但牙医组使用ERA的SBS比学生组高1.65 MPa ± 0.73。干燥和微湿牙本质表面条件下的SBS值高于湿性表面(分别为P 0.001和P 0.002),而微湿与干燥表面之间未观察到显著差异。所测试的UA无论操作者和DMC如何均提供了可靠的结果。

Abstract

To determine the influence of operators' experience, dentin moisture condition (DMC), and adhesive type on shear bond strength, and evaluate the consistency of adhesive performance under these conditions to demonstrate clinical reliability. Six hundred sound dentin surfaces were randomly divided by five dentists with at least 10 years of experience (n = 300/5 dentists) and five first-year dental students without dental experience (n = 300/5 students). Each operator applied universal (UA) (Adhese Universal, Ivoclar) and etch-and-rinse (ERA) (OptiBond FL, Kerr) adhesives (n = 60/adhesive type) before and after receiving demonstration on the manufacturers' recommended application techniques by the principal investigator (PI), on wet, moist, and dry dentin surfaces (n = 5/DMC). DMCs were obtained by the PI before the operators applied the adhesives. The PI applied composite restorations (Tetric EvoCeram Bulk Fill, Ivoclar) and polymerized for 20 s. Shear bond strength (SBS) test was conducted after 24 h storage at 37°C, in 100% humidity. Boxplot, Log Worth, and Tukey HSD were used for statistics. The median SBS of ERA obtained by dentists was 17.79 MPa with an interquartile range (IQR) of 19.61, while students showed a lower median of 13.52 MPa with IQR of 15.81. The UA showed consistency in SBS and reduced variability across operators with median SBS by dentists and students (25.53 MPa and 24.96 MPa, respectively), with narrower IQRs of 10.6 and 7.3, respectively. SBS of UA was significantly higher than ERA (P 0.001). UA obtained 7.38 MPa ± 0.89 greater SBS than ERA. While no difference in SBS by operator was observed for UA, dentists obtained 1.65 MPa ± 0.73 greater SBS than students with ERA. Dry and moist dentin surface conditions yielded higher SBS values compared to wet surfaces (P 0.001 and P 0.002, respectively), with no significant differences observed between moist and dry surfaces. The tested UA provided reliable outcomes regardless of operator and DMC.

如何引用

AMA

Marwa Bawazir, Sibel A Antonson. Operator Experience Does Not Affect the Reliability of Universal Adhesives' Bond Strength; Adhesive Type Does.. The journal of adhesive dentistry. 2026; doi:10.3290/j.jad.c_2675.

APA

Marwa Bawazir, Sibel A Antonson (2026). Operator Experience Does Not Affect the Reliability of Universal Adhesives' Bond Strength; Adhesive Type Does.. The journal of adhesive dentistry. https://doi.org/10.3290/j.jad.c_2675

GB/T 7714

Marwa Bawazir, Sibel A Antonson. Operator Experience Does Not Affect the Reliability of Universal Adhesives' Bond Strength; Adhesive Type Does.[J]. The journal of adhesive dentistry, 2026 doi:10.3290/j.jad.c_2675.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

The journal of adhesive dentistry 的其他文献