European Journal of Oral Implantology欧洲口腔种植学杂志
European Journal of Oral Implantology,ISSN 1756-2406,eISSN 1756-2414,中文译名:欧洲口腔种植学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2020 | 3.123 | Q2 |
European Journal of Oral Implantology 最新收录文献
-
1. From the maxillary sinus to the stomach: a rare case report of a displaced fragment of dental implant.
PMID:日期:2018To present a rare clinical case of migration of a displaced implant fragment from the maxillary sinus to the stomach. A 66-year-old man was referred from a local dental clinic to remove a displaced implant apical fragment in the left maxillary sinus. After 15 days from the displacement, no foreign body was seen in the maxillary sinus or in any other craniofacial cavity. Thoracic and abdominal radiographs were taken, and a 3 × 3 mm radiopaque object, which corresponded to the piece of implant fragment, was detected within the patient's stomach. Follow-up radiographs were taken to monitor the progress after 1 week, and it was found that the radiopaque object had disappeared. A displaced dental implant fragment in the maxillary sinus can migrate and exit from the maxillary sinus within a few days. Since it presents a potential risk for swallowing or aspiration, displaced implants or other objects in the maxillary sinus should be removed immediately. Before removal, additional radiographs are recommended to confirm the current position of the implant.
-
2. Non-surgical mechanical treatment of peri-implant mucositis: the effect of sub-mucosal mechanical instrumentation following supra-mucosal plaque removal. A 7-month prospective single cohort study.
PMID:日期:2018To evaluate the effect of sub-mucosal mechanical instrumentation following supra-mucosal plaque removal in the treatment of peri-implant mucositis. A total of 44 patients, 27 from a specialist clinic in Sweden, and 17 from a Japanese one, were included. The 44 patients had a total of 175 implants of which 84 (48%) had clinical signs of mucositis (bleeding on probing [BoP]) and no radiographic bone loss. At baseline, the 44 patients received professional supra-mucosal plaque removal and oral hygiene instruction and motivation. Following the 1-month examination, sub-mucosal instrumentation was initiated using ultrasonic and hand instruments. Patients were then examined at 4 and 7 months. Presence of plaque, marginal bleeding, BoP and probing pocket depth (PPD) changes were recorded at each examination in an unblinded manner. One month following supra-mucosal plaque removal, the number of treated implants with BoP was reduced from 84 to 44 (48% reduction) with a concomitant decrease of the mean PPD of 0.6 mm (95% CI: -0.5 to -0.7), from 4.4 ± 1.0 mm (mean ± SD) to 3.8 ± 1.0 mm, P < 0.0001. Following sub-mucosal instrumentation, a further reduction of 9% (from 44% to 36%) of BoP was recorded, with a concomitant reduction of the mean PPD of 0.3 mm (95% CI: -0.1 to -0.4) at the 7-month examination. The improvement of the clinical condition (absence of marginal bleeding, BoP and PPD reduction at treated implants) following non-surgical treatment of mucositis appeared to be in great part because of supra-mucosal plaque removal, while the sub-mucosal instrumentation seemed to have only a minor additional effect. Deep implant position compared to neighbouring teeth/implant was associated with persisting mucositis following treatment. The presence of deep pockets following treatment was associated with BoP, screw-retained prostheses without abutment and sub-mucosal crown margins.
-
3. Comparing membranes and bone substitutes in a one-stage procedure for horizontal bone augmentation. Three-year post-loading results of a double-blind randomised controlled trial.
PMID:日期:2018The objective of this 3-year post-loading parallel randomised controlled trial is to compare two bone substitutes and resorbable membranes in a one-stage procedure for horizontal bone augmentation: anorganic bovine bone and porcine collagen membranes (BB group) versus synthetic resorbable bone graft substitute made of pure β-tricalcium phosphate and porcine pericardium collagen membranes (CJ group). Patients in need of implant treatment having at least one site with horizontal osseous defect at a private clinic in Rimini, Italy, were included in this study. Patients were randomised to receive either BB or CJ in a one-stage procedure for horizontal bone augmentation in a submerged approach. Randomisation was computer-generated with allocation concealment by opaque sequentially numbered sealed envelopes. Patients and the outcome assessor were blinded to group assignment. The abutment connection was made after 6 months of healing. The application of the provisional prosthesis was performed after abutment connection and a definitive metal-ceramic prosthesis was placed 6 months post-loading. The patients were followed-up to 3 years post-loading. Primary outcome measures were: implant failure, complications and peri-implant margin bone level changes. Secondary outcome measures were: visual analogue scale (VAS) for functional and aesthetic satisfaction and pink aesthetic score (PES). Twenty-five patients with 32 implants were randomly allocated to the BB group and 25 patients with 29 implants to the CJ group. All 50 randomised patients received the treatment as allocated and there were 7 drop-outs in the BB group and 11 drop-outs in the CJ group up to 3 years' post-loading. There were no implant failures. There were six complications in five patients of the BB group and three complications in three patients of the CJ group (relative risk: 1.32, 95% CI from 0.37 to 4.64, P = 1.0000). Radiographic bone loss was 1.61 mm for the BB group and 1.02 mm for the CJ group (difference 0.54 mm, 95% CI from -0.53 to 1.60, P = 0.3100). The functional VAS was 9.0 for the BB group and 9.6 for the CJ group (difference 0.6, 95% CI from -0.4 to 1.5, P = 0.2393). The aesthetic VAS was 9.4 for the BB group and 9.6 for the CJ group (difference 0.2, 95% CI from -0.5 to 0.8, P = 0.6141). PES was 8.7 for the BB group and 8.5 for the CJ group (difference -0.1, 95% CI from -2.9 to 2.7, P = 0.9360). No significant differences were observed in this randomised controlled trial comparing anorganic bovine bone with porcine collagen membranes versus synthetic resorbable bone made of pure β-tricalcium phosphate with pericardium collagen membranes for horizontal augmentation.
-
4. Endodontic retreatment versus dental implants of teeth with an uncertain endodontic prognosis: 3-year results from a randomised controlled trial.
PMID:日期:2018To ascertain whether in the presence of a previously endodontically treated tooth with periapical pathology and/or symptoms and an uncertain prognosis, it is better to endodontically retreat it or to replace the tooth with a single-implant-supported crown. Twenty patients requiring the treatment of a previously endodontically treated tooth, with periapical pathology and/or symptoms of endodontic origin and an uncertain prognosis, as judged by the recruiting investigator, were randomly allocated to endodontic retreatment (Endo group, 10 patients) or tooth extraction and replacement with an implant-supported crown (Implant group, 10 patients) according to a parallel-group design at a single centre. Patients were followed to 3 years after completion of the treatment. Outcome measures were: failure of the procedure, complications, marginal bone level changes at both teeth and implants, endodontic radiographic success (teeth only), number of patients' visits and days to complete the treatment, patients' chair time, costs, aesthetics assessed using the pink aesthetic score (PES) for the soft tissues and the white aesthetic score (WES) for the tooth/crown recorded by independent assessors. No patient dropped out. One endodontically retreated tooth fractured and another had a crown loosening. There were no statistically significant differences for treatment failure or complications (difference in proportions = 0.10; 95% CI: -0.09 to 0.29; P (Fisher exact test) = 1.000). The mean marginal bone levels at endodontic retreatment/implant insertion were 2.10 ± 0.66 mm for the Endo group and 0.05 ± 0.15 mm for the Implant group. Three years after completion of the treatment, teeth lost on average 0.23 ± 0.82 mm and implants 0.62 ± 0.68 mm, the difference not being statistically significant (mean difference = -0.39 mm; 95% confidence interval [CI]: -1.12 to 0.33; P (t test) = 0.267). Three years after completion of the endodontic retreatment, of the four teeth that originally had a periapical radiolucency, one was lost, two showed complete healing, and one showed radiographic improvement. There were no statistically significant differences for the number of patients' visits (Endo = 6.67 ± 0.71; Implant = 6.10 ± 0.74; mean difference = 0.57; 95% CI: -0.14 to 1.27; P (t test) = 0.106). It took significantly more days to complete the implant rehabilitation (Endo = 61 ± 12.97; Implant = 191.40 ± 75.04; mean difference = -130.40; 95% CI: -184.45 to -76.35; P (t test) < 0.001) but less patients' chair time (Endo = 629.44 ± 43.62 min; Implant = 326 ± 196.99 min; mean difference = 303.44; 95% CI: 160.87 to 446.02; P (t test) = 0.001). Implant treatment was significantly more expensive (Endo = €1,588.89 ± 300.81; Implant = €2,095 ± 158.90; mean difference = €-506.11; 95% CI: -735.41 to -276.82; P (t test) < 0.001). Three years after treatment completion, mean PES were 11.11 ± 1.97 and 6.50 ± 2.46 and mean WES were 7.78 ± 1.30 and 6.80 ± 2.39 in the Endo group and Implant group, respectively. Soft tissues aesthetics (PES) were significantly better at endodontically retreated teeth (mean difference 4.61; 95% CI: 2.44 to 6.78; P (t test) < 0.001) whereas no significant differences were observed for tooth aesthetics (WES) (mean difference 0.98; 95% CI: -0.89 to 2.85; P (t test) = 0.281) between treatments. The present preliminary results suggest that both endodontic retreatment and replacement of previously endodontically treated teeth with persisting pathology and a dubious endodontic prognosis provided similar short-term success rates. Aesthetics of the soft tissues and time needed to complete treatment were in favour of endodontic retreatment whereas implant rehabilitation required half of the chair time than endodontic retreatment, but was significantly more expensive. Much larger patient populations and longer follow-ups are needed to fully answer this question; however, in this scenario the less invasive endodontic retreatment could be the first therapeutic option to be considered.
-
5. Immediate non-occlusal versus delayed loading of mandibular first molars. Five-year results from a randomised controlled trial.
PMID:日期:2018To compare outcomes of immediate non-occlusal loading with delayed implant loading in the bilateral replacement of mandibular first molars. This study was designed as a split-mouth, randomised controlled trial. Twenty patients with bilaterally missing mandibular first molars randomly received immediately or conventionally loaded single implants. One molar was restored with a non-occlusal temporary crown within 24 hours after implant placement (immediate loading group, IL) while the contralateral molar was restored with a definitive crown 4 to 5 months later (delayed loading group, DL). A total of 40 implants were installed. All implants were inserted in healed bone with an insertion torque between 35 and 45 Ncm. Outcome measures were implant failure, complications, radiographic marginal bone level changes, probing pocket depths (PPDs) and bleeding on probing (BOP). Clinical data were collected at implant placement, and after 6, 12 and 60 months. No patients dropped out and no implant failed. Only minor prosthetic complications were observed (two provisional acrylic crown fractures in the IL group and four ceramic chipping in the DL group). Two patients had bilateral peri-implant mucosal inflammation with BOP after 6 months. The differences between groups were not statistically significant (OR = 0.500; 95% CI: 0.045 to 3.489; P = 0.6831). At the 1-year follow-up examination, the mean marginal bone level was 0.83 ± 0.16 mm (95% CI: 0.75 to 0.91) in the IL group and 0.86 ± 0.16 mm (95% CI: 0.78 to 0.94) in the DL group, with no statistically significant differences between groups (difference = 0.03 ± 0.15 mm; 95% CI: -0.07 to 0.07; P = 0.53). After 5 years, mean marginal bone level was 1.06 ± 0.38 mm (95% CI: 0.97 to 1.15) in the IL group and 1.07 ± 0.32 mm (95% CI: 0.95 to 1.16) in the DL group, with no statistically significant differences between groups (difference = 0.01 ± 0.22 mm; 95% CI: -0.10 to 0.10; P = 0.96). The mean marginal bone loss after 5 years was 0.62 ± 0.45 mm in the IL group and 0.69 ± 0.33 mm in the DL group (difference = 0.07 ± 0.32 mm; 95% CI: -0.10 to 0.18; P = 0.567). At the 5-year follow-up the mean PPD and BOP values were 2.82 ± 0.65 mm and 1.17 ± 0.92 in the IL group, and 2.85 ± 0.53 mm and 1.17 ± 0.86 in the DL group, respectively. No significant differences were found (difference = 0.03 ± 0.15 mm; 95% CI: -0.15 to 0.21; P = 0.990; and 0.01 ± 0.07; 95% CI: -0.06 to 0.08; P = 1.000, respectively). Within the limitations of this study, the present data seem to confirm the hypothesis that the clinical outcome of immediate versus delayed loading of implants in mandibular fist molar sites is comparable.
-
6. Do we need abutments at immediately loaded implants supporting cross-arch fixed prostheses? Results from a 5-year randomised controlled trial.
PMID:日期:2018To compare the clinical outcome (in particular of marginal peri-implant bone level changes) between immediately loaded straight implants which had definitive abutments placed at implant placement and never removed versus implants which had no intermediate abutments. Thirty-two edentulous patients had one of their jaws rehabilitated with a provisional screw-retained resin reinforced cross-arch fixed prosthesis supported by four immediately loaded implants: two central straight implants and two either tilted or straight distal implants. The two central straight implants were randomly allocated in two equal groups to receive or not an intermediate abutment (Multi-Unit Abutment, MUA) according to a parallel group design. To be immediately loaded implants had to be inserted with a minimum torque of 30 Ncm, which was achieved by all implants. After 4 months, definitive screw-retained metal-ceramic prostheses were delivered and patients were followed-up to 5 years after loading. Prostheses were removed every 8 months to facilitate professionally delivered maintenance. Outcome measures were prosthesis and implant failures, complications, peri-implant marginal bone level changes and bleeding on probing (BoP). Five-years after loading one patient dropped out from each group. No implant or prosthetic failure occurred. Three patients of the abutment group versus one of the no-abutment group were affected by complications (risk difference = 0.125; 95% CI: -0.13 to 0.37; Fisher exact test, P = 0.600). At 5 years, both groups lost marginal bone in a statistically significant way (0.32 ± 0.40 mm for patients of the abutment group and 0.35 ± 0.29 mm for patients of the no-abutment group), with no difference in bone loss between groups at patient levels (difference = 0.03 mm; 95% CI: -0.23 to 0.29 mm; P = 0.809). At 5 years, BoP was significantly higher in the no-abutment group than in the abutment group (difference between medians = 25%; 95% CI: 12.5% to 25%; P < 0.001). By considering only the average of the two central study implants per patient with and without intermediate abutments, there were no differences in bone loss (difference: -0.05 mm; 95% CI: -0.41 to 0.31 mm; P = 0.763), while marginal bleeding was significantly higher in the no-abutment group (difference between medians = 25%; 95% CI: 0% to 50%; P = 0.004). The present results suggest that intermediate abutments may not be needed at immediately loaded cross-arch screw-retained prostheses, unless there is the necessity to correct implant angulation.
-
7. Short implants versus longer implants in vertically augmented posterior mandibles: result at 8 years after loading from a randomised controlled trial.
PMID:日期:2018To evaluate whether 6.6-mm long implants could be a suitable alternative to longer implants placed in vertically augmented atrophic posterior mandibles. Sixty partially edentulous patients having 7 to 8 mm of residual crestal height and at least 5.5-mm thickness measured on computed tomography scans above the mandibular canal were randomly allocated according to a parallel-group design either to receive one to three submerged 6.6-mm long implants or 9.6-mm or longer implants (30 patients per group) placed in vertically augmented bone. Bone was augmented with interpositional anorganic bovine bone blocks fixed with titanium plates and covered with resorbable barriers. Grafts were left to heal for 5 months before implant placement. Four months after implant placement, provisional acrylic prostheses were delivered, replaced, after 4 months, by definitive metal-ceramic prostheses. Outcome measures were: prosthesis and implant failures, complications, and radiographic peri-implant marginal bone level changes. Patients were followed up to 8 years after loading. Eight years after loading 12 patients dropped out, five from the short implant group and seven from the augmented group. The augmentation procedure failed in two patients and only 6.6-mm long implants could be inserted. There were no statistically significant differences for prosthesis and implant failures. Four prostheses failed in three patients of the short implant group versus three prostheses in three patients of the augmented group (Fisher exact test P = 1.000; difference in proportions = 0.01; 95% CI: -0.19 to 0.22). Five short implants failed in three patients versus three long implants in three patients (Fisher exact test P = 1.000; difference in proportions = 0.01; 95% CI: -0.19 to 0.22). There were statistically more complications in augmented patients (27 complications in 22 augmented patients versus 9 complications in 8 patients of the short implant group) (Fisher exact test P < 0.001; difference in proportions = 0.64; 95% CI: 0.38 to 0.79). Both groups gradually lost peri-implant bone in a statistically significant way. Eight years after loading, short implant group patients lost an average of 1.58 mm of peri-implant bone compared with 2.46 mm in the augmented group. Short implants experienced statistically significantly less bone loss (0.88 mm, 95% CI: 0.50 to 1.26 mm) than long implants. When residual bone height over the mandibular canal is between 7 and 8 mm, 6.6-mm short implants are an interesting alternative to vertical augmentation in posterior atrophic mandibles since the treatment is faster, cheaper and associated with less morbidity.
-
9. Research in focus.
PMID:日期:2018This section presents a brief review of articles on dental implants considered of special interest for the reader, in order to encourage the developing of research, the interest for data analysis and the attention to scientific publications. Your comments are welcome. Please contact Dr Michele Nieri at michelenieri@gmail.com.
-
10. A controlled study on the accuracy and precision of intraoral radiography in assessing interproximal bone defect morphology around teeth and implants.
10. 口内X线摄影评估牙及种植体周围邻面骨缺损形态准确性与精密度的对照研究PMID:日期:2018The primary objective of the present controlled study was to determine the accuracy and precision of intraoral radiography in assessing interproximal bone defect morphology in patients suffering from periodontal disease as well as in patients with peri-implantitis. A secondary objective was to evaluate the possible impact of clinical experience on accuracy and precision. The study sample comprised a total of 99 interproximal bony defects (40 patients) needing surgical treatment. Forty-nine defects were periodontal (17 patients), while the remaining 50 were peri-implant defects (23 patients). Following reflection of a mucoperiosteal flap and removal of granulation tissue, the type of bone defect as classified by Goldman and Cohen (1958) was determined. This intrasurgical registration was considered the true bone defect morphology. An intraoral radiograph was taken for each interproximal site. Twenty clinicians determined the bone defect morphology on each intraoral radiograph twice, with a washout period of 3 months. Using the Goldman and Cohen (1958) classification, the overall accuracy of intraoral radiography in assessing interproximal bone defect morphology was slight for teeth/implants (κ = 0.132; 95% CI: 0.091 to 0.173/κ = 0.126; 95% CI: 0.091 to 0.162). Duplicate evaluation indicated fair precision (κ = 0.369; 95% CI: 0.308 to 0.430/κ = 0.355; 95% CI: 0.230 to 0.414). Pooling one-, two- and three-wall defects into one category had a positive impact on accuracy (κ = 0.254; 95% CI: 0.201 to 0.307/κ = 0.387; 95% CI: 0.340 to 0.435), as well as on precision (κ = 0.504; 95% CI: 0.423 to 0.584/κ = 0.560; 95% CI: 0.463 to 0.657). A significant difference between experienced clinicians and trainees was not found (P ≥ 0.285). Intraoral radiography lacks accuracy for assessing interproximal bone defect morphology around teeth and implants. Clinical experience does not seem to influence this.