Iranian Journal of Radiology伊朗放射学杂志
Iranian Journal of Radiology(英文缩写 IRAN J RADIOL),ISSN 1735-1065,eISSN 2008-2711,中文译名:伊朗放射学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 0.399 | Q4 |
| 2022 | 0.300 | Q4 |
| 2023 | 0.200 | Q4 |
| 2024 | 0.400 | Q4 |
| 2025 | 0.100 | Q4 |
Iranian Journal of Radiology 最新收录文献
-
1. Comparison of Open-Cell Stent and Closed-Cell Stent for Treatment of Central Vein Stenosis or Occlusion in Hemodialysis Patients.
1. 开放细胞支架和闭细胞支架治疗血液透析患者中心静脉狭窄或闭塞的比较PMID:期刊:日期:2016-09-11Central vein stenosis or occlusion is a common complication that can lead to significant morbidity and dysfunction of access in the hemodialysis patient. More lesions can develop over time, and preserving access becomes a challenge as life expectancy of the hemodialysis patient increases. The goal was to compare long-term results and determine the outcomes of open-cell stent versus closed-cell stent for central vein stenosis or occlusion in hemodialysis patients. From 1997 to 2015, in 401 hemodialysis patients, stent placement for central vein stenosis or occlusion was performed if balloon angioplasty was unsatisfactory, due to elastic recoil or occurrence of restenosis within 3 months. When thrombus was present, primary stenting was performed. A total of 257 open-cell stents and 144 closed-cell stents were used. Angiographic findings including lesion site, central vein stenosis or occlusion, and presence of thrombosis and complication were evaluated. Primary patency rate and mean patency rate of the stent were compared between two stent groups by Kaplan-Meier survival analysis. For the open-cell stent group, 159 patients were diagnosed as central vein stenosis and 98 were occlusion. For the closed-cell stent group, 78 were stenosis and 66 were occlusion. There were two complications for central migration and two for procedure-related vein rupture. Open-cell stents and closed-cell stents had mean patency rates of 10.9 ± 0.80 months and 8.5 ± 10.87 months, respectively (P = 0.002). The open-cell stent is effective and its performance is higher than that obtained with the closed-cell stent for treating central vein stenosis or occlusion in hemodialysis patients.
-
2. Primary Pleural Synovial Sarcoma with Metastatic Cardiac Involvement: A Case Report.
PMID:期刊:日期:2016-09-07Primary pleuropulmonary synovial sarcomas are rare soft tissue malignancies; combined metastatic involvement of the heart is extremely rare. In this case report, a 17-year-old female presented with a history of chest pain. Chest radiographs revealed a round mass in the left upper hemithorax, and computed tomography (CT) showed a well-defined heterogeneous enhancing mass abutting the pleura. A core needle biopsy revealed malignant spindle cells. Surgical resection was performed, and a final diagnosis of primary pleural synovial sarcoma, monophasic fibrous type, was made. The patient underwent radical irradiation and chemotherapy and remained stable for 28 months until a follow-up chest CT showed a poorly enhancing nodule in the left pericardial region that enlarged after 5 months. Surgical resection was performed. Histological examination confirmed metastatic cardiac involvement from a primary pleural synovial sarcoma. We report this unusual case of a primary pleural synovial sarcoma metastasis to the heart.
-
3. Evaluation of Visibility of Foreign Bodies in the Maxillofacial Region: Comparison of Computed Tomography, Cone Beam Computed Tomography, Ultrasound and Magnetic Resonance Imaging.
PMID:期刊:日期:2016-08-10Detection of foreign bodies (FBs) is challenging. Selection of a fast and affordable imaging modality to locate the FB with minimal patient radiation dose is imperative. This study sought to compare four commonly used imaging modalities namely cone beam computed tomography (CBCT), magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound (US) for detection of FBs in the head and neck region. In this in vitro study, iron, glass, stone, wood, asphalt, and tooth samples measuring 0.1 × 0.5 × 0.5 cm were placed in the tongue muscle, soft tissue-bone interface and nasal cavity in a fresh sheep's head and subjected to MRI, US, CT and CBCT. A total of 20 images were captured by each imaging system from the six materials in the afore-mentioned locations. The images were observed by an expert oral and maxillofacial radiologist and a general radiologist. To assess reliability, 20 images were randomly observed by the observers in two separate sessions. The images were classified into three groups of good visibility, bad visibility and invisible. The data were analyzed using SPSS version 18, Wilcoxon Signed Rank, Pearson chi square, and Fisher's exact tests. All FBs in the tongue and at the soft tissue-bone interface had good visibility on US (P = 1.00). Also, CBCT and CT had significantly different performance regarding FB detection (P < 0.001). All wooden samples in the nasal cavity were invisible on CT scans; while, only 20% of them were invisible on CBCT scans. MRI showed significant differences for detection of FBs in the three locations (P < 0.001). MRI could not locate iron samples due to severe artifacts and only showed their presence (bad visibility) but other FBs except for wood and tooth in the nasal cavity (100% invisible) had good visibility on MRI. Ultrasound is recommended as the first choice when FB is located within the superficial soft tissues with no bone around it. In case of penetration of FB into deeper tissues or beneath bone, CT or CBCT are recommended. Otherwise, considering lower dose, CBCT is preferred over CT. We can use MRI if the FB is not ferromagnetic. However, CT is the first choice in emergency situations because of higher sensitivity.
-
4. Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus.
PMID:期刊:日期:2016-08-01To evaluate morphologic variations at the aortic isthmus with particular attention to ductus diverticulum, a mimicker of traumatic pseudoaneurysm, and to describe differences using Computed Tomography (CT) images. From December 2013 to December 2014, patients who underwent a chest CT examination after blunt trauma at our emergency department were included. Aortic isthmus morphologies were evaluated using multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images as follows. Type I -concave contour, type II -convexity without a discrete bulge, or type III -a discrete focal bulge (defined as ductus diverticulum). After excluding 11 cases of traumatic pseudoaneurysm of the aortic isthmus, a total of 432 trauma patients (mean age = 47.1 ± 19.1 years, number of males = 318) were evaluated for aortic isthmus morphology, and classified as follows; type I (n = 240, 55.6%), type II (n = 157, 36.3%), and type III (n = 35, 8.1%). As compared with traumatic pseudoaneurysm (n = 11), ductus diverticulum had a smaller vertical diameter (5.5 ± 1.3 mm vs. 11.2 ± 2.7 mm, P < 0.001), a broader base (14.9 ± 4.1 mm vs. 8.8 ± 4.5 mm, P < 0.001), a smoother margin (97.1% vs. 27.3%, P < 0.001), and formed obtuse angle with the aortic wall. Furthermore, ductus diverticulum was not associated with the presence of a dissection flap or hemomediastinum. Ductus diverticulum, a mimicker of traumatic pseudoaneurysm of the aortic isthmus, is a frequently observed anatomic variant during CT examinations. Familiarity with its CT imaging findings could avoid it being confused with traumatic pseudoaneurysm in blunt trauma patients.
-
5. Unexplained Cardiac Arrest After Near Drowning in a Young Experienced Swimmer: Insight from Cardiovascular Magnetic Resonance Imaging.
PMID:期刊:日期:2016-08-01Cardiac magnetic resonance imaging (cMRI) is a well-established noninvasive imaging modality in clinical cardiology. Its ability to provide tissue characterization make it well suited for the study of patients with cardiac diseases. We describe a multi-modality imaging evaluation of a 45-year-old man who experienced a near drowning event during swimming. We underline the unique capability of tissue characterization provided by cMRI, which allowed detection of subtle, clinically unrecognizable myocardial damage for understanding the causes of sudden cardiac arrest and also showed the small damages caused by cardiopulmonary resuscitation.
-
6. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.
PMID:期刊:日期:2016-08-01X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.
-
7. Computerized Tomography and Magnetic Resonance Imaging Findings in Malignant Perivascular Epithelioid Cell Tumors of the Ovaries with Pulmonary Metastasis.
PMID:期刊:日期:2016-08-01Perivascular epithelioid cell tumor (PEComa) is a rare mesenchymal tumor composed of immunohistochemically and histologically distinctive perivascular epithelioid cells. Here, we report on the computed tomography (CT) and magnetic resonance imaging (MRI) findings of ovarian PEComa with pulmonary metastasis. The tumor was visible as a multilocular hemorrhagic mass that encased the ovarian vessels. These findings were different to those of other common ovarian tumors.
-
8. Takeaways from Pre-Contrast T1 and T2 Breast Magnetic Resonance Imaging in Women with Recently Diagnosed Breast Cancer.
PMID:期刊:日期:2016-07-18Dynamic contrast-enhanced magnetic resonance imaging (DCE - MRI) has been widely used in the management of breast cancer, and its diagnostic value in breast imaging has been demonstrated. There have only been a few reports regarding the usefulness of pre-contrast imaging. Knowledge about clinically significant findings of preoperative, pre-contrast T1 and T2 MR images will allow more accurate decisions regarding patient treatment and management. The aim of this study was to evaluate the clinically significant findings of preoperative, pre-contrast T1 and T2 MR images in recently diagnosed breast cancer patients. We analyzed 390 preoperative 3-T MRIs of recently diagnosed breast cancer patients in whom the diagnosis was confirmed by a core needle biopsy. MRI findings that were correlated with post-core needle-biopsy changes were observed in 27.9% of the pre-contrast T1 and T2 MRIs (n = 109/390). Two of 35 cases that had a subareolar ductal high signal area on the pre-contrast T1 were confirmed by surgery as having nipple-areolar complex involvement. A subareolar ductal high signal area on a pre-contrast T1 MRI must be carefully assessed in combination with dynamic, contrast-enhanced images for proper surgical management.
-
9. Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography.
PMID:期刊:日期:2016-07-05Selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed tomography (CBCT) is particularly important. This study aimed to assess the effect of voxel size on detection accuracy of simulated external root resorption defects using NewTom CBCT system. In this diagnostic study, the roots of 90 extracted human central incisors were hypothetically divided into cervical, middle, and apical thirds. Variable-size defects were prepared in the buccal and lingual surfaces of the roots and CBCT scans were obtained with four different voxel sizes (150, 200, 250, and 300). Presence or absence of defects on CBCT scans was determined by three radiologists and the results were compared with the gold standard (actual size and depth of defects). Sensitivity and specificity values were calculated and reported for different groups. In the lingual surfaces, the highest specificity and sensitivity belonged to 300µm voxel size (92.9%), and 200 and 250µm voxel sizes (both 97.4%) in the cervical third, respectively. In the middle third, the highest specificity and sensitivity belonged to 250 and 200µm voxel sizes (84.6% and 100%, respectively). In the apical third, the highest specificity and sensitivity belonged to 300 µm voxel size (100% and 97.9%, respectively). In the buccal surfaces, the highest specificity and sensitivity belonged to 150 (75.0%), 300 and 250 µm voxel sizes (100%) and the minimum values belonged to 200 µm voxel size (60% and 97.3%) in the cervical third. In the apical third, the highest specificity and sensitivity were noted in 300 µm voxel size (100% and 97.6%, respectively) and the minimum values were seen in 200 and 150 µm voxel sizes (93.8%, 90.5%, respectively). In the middle third, 300, 250 and 200 µm voxel sizes yielded the highest specificity (88.9%), while 150 µm voxel size yielded the highest sensitivity (98.8%). Considering the similar diagnostic efficacy of all voxel sizes, 300 µm voxel size can be used with adequate efficacy for detection of external root resorption defects with minimal patient radiation dose and the shortest scanning time.
-
10. Investigation of Factors Affecting Body Temperature Changes During Routine Clinical Head Magnetic Resonance Imaging.
PMID:期刊:日期:2016-07-04Pulsed radiofrequency (RF) magnetic fields, required to produce magnetic resonance imaging (MRI) signals from tissue during the MRI procedure have been shown to heat tissues. To investigate the relationship between body temperature rise and the RF power deposited during routine clinical MRI procedures, and to determine the correlation between this effect and the body's physiological response. We investigated 69 patients from the Korean national cancer center to identify the main factors that contribute to an increase in body temperature (external factors and the body's response) during a clinical brain MRI. A routine protocol sequence of MRI scans (1.5 T and 3.0 T) was performed. The patient's tympanic temperature was recorded before and immediately after the MRI procedure and compared with changes in variables related to the body's physiological response to heat. Our investigation of the physiological response to RF heating indicated a link between increasing age and body temperature. A higher increase in body temperature was observed in older patients after a 3.0-T MRI (r = 0.07, P = 0.29 for 1.5-T MRI; r = 0.45, P = 0.002 for 3.0-T MRI). The relationship between age and body heat was related to the heart rate (HR) and changes in HR during the MRI procedure; a higher RF power combined with a reduction in HR resulted in an increase in body temperature. A higher magnetic field strength and a decrease in the HR resulted in an increase in body temperature during the MRI procedure.