EUROPACE欧洲心脏起搏与电生理杂志
EUROPACE(英文缩写 EUROPACE),ISSN 1099-5129,eISSN 1532-2092,中文译名:欧洲心脏起搏与电生理杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.486 | Q2 |
| 2022 | 6.100 | Q1 |
| 2023 | 7.900 | Q1 |
| 2024 | 7.400 | Q1 |
| 2025 | 10.200 | Q1 |
EUROPACE 最新收录文献
-
1. LifeRhythms: The continuous commitment of the European Heart Rhythm Association in the field of arrhythmias and electrophysiology.
1. 生命节律:欧洲心律协会在心律失常和电生理领域的持续承诺PMID:期刊:日期:2026-10-05该文献暂无摘要。
-
2. Percutaneous Left Atrial Appendage Closure: The CHAMPION-like vs CLOSURE-like Patient Phenotype Framework.
2. 经皮左心耳封堵术:类CHAMPION与类CLOSURE患者表型框架PMID:期刊:日期:2026-10-05The near-simultaneous publication of CHAMPION-AF and CLOSURE-AF produced apparently discordant evidence regarding percutaneous left atrial appendage closure (LAAC) for stroke prevention in atrial fibrillation. We aimed to reconcile these findings through a phenotype-based framework and identify the determinants of net clinical benefit. This narrative review integrates randomized trials, registries, consensus documents, and guidelines, focusing on patient selection, procedural risk, post-implant antithrombotic therapy, endpoint construction, competing mortality, and time to benefit. CHAMPION-AF evaluated LAAC against direct oral anticoagulation in an elective, anticoagulation-eligible population with lower bleeding risk, demonstrating non-inferior thromboembolic protection and less non-procedural bleeding. Conversely, CLOSURE-AF enrolled an older, multimorbid population with substantial renal dysfunction, previous bleeding, and high competing mortality. Although implantation success and stroke rates were comparable between treatment groups, early procedural and antithrombotic-related bleeding, a composite endpoint incorporating procedural events, and limited survival reduced the opportunity for delayed benefit. The highly selective recruitment pathway further limits generalisability. These findings define a continuum from the "CHAMPION-like" patient, with sufficient physiological reserve and life expectancy to realise long-term benefit, to the "CLOSURE-like" patient, in whom frailty and competing risk may outweigh the advantage of appendage exclusion. LAAC efficacy is not determined by device performance alone but by matching the intervention to patient phenotype and time horizon. Selection should integrate thromboembolic and bleeding risk, frailty, renal function, post-implant treatment tolerance, and expected survival. Future trials require transparent screening data, time-sensitive endpoints, landmark analyses, and competing-risk methods.
-
3. Clinical relevance of lead-induced tricuspid regurgitation after transvenous ICD implantation in arrhythmogenic cardiomyopathy.
3. 致心律失常性心肌病患者经静脉ICD植入后铅致三尖瓣反流的临床相关性PMID:期刊:日期:2026-10-03该文献暂无摘要。
-
4. Delayed structural myocardial injury after stereotactic arrhythmia radioablation: A serial CMR study in a porcine model.
PMID:期刊:日期:2026-10-03该文献暂无摘要。
-
5. Correction to: Transforming atrial fibrillation management by targeting comorbidities and reducing atrial fibrillation burden: the 10th AFNET/EHRA consensus conference.
5. 更正:通过针对合并症和减少房颤负担来转变房颤管理:第10届AFNET/EHRA共识会议PMID:期刊:日期:2026-10-01该文献暂无摘要。
-
6. Subcutaneous and Extravascular Implantable Cardioverter-Defibrillators: A Clinical Framework for Breast Surgery, Pregnancy, Lactation, Radiation Therapy, and Breast Imaging.
6. 皮下和血管外植入式心律转复除颤器:乳房手术、妊娠、哺乳、放射治疗和乳腺成像的临床框架PMID:期刊:日期:2026-09-29The subcutaneous implantable cardioverter-defibrillator and extravascular implantable cardioverter-defibrillator do not require intravascular, intracardiac, or epicardial leads, making them attractive alternatives to transvenous implantable cardioverter defibrillators in patients without bradycardia pacing or cardiac resynchronization therapy indications. These systems are especially useful for patients with venous access challenges and those at risk for endovascular infections, including patients with renal failure or those who are immunocompromised. Women with prior or anticipated breast surgery, such as mastectomy or breast reconstruction surgery, or those who are lactating present unique anatomic, procedural, and post-operative quality-of-life considerations. This commentary provides a practical, scenario-based framework for managing this unique patient group. Key considerations include individualized incision and pulse generator planning, proactive multidisciplinary coordination, procedure-specific management, and shared decision-making in patients with prior or anticipated breast augmentation or reduction, pregnancy, lactation, mastectomy, radiation therapy, and breast imaging.
-
7. Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing.
7. 在巴赫曼束起搏期间使用V8导联对左心房激动进行无创评估PMID:期刊:日期:2026-09-25Bachmann bundle pacing (BBP) improves atrial synchrony by advancing LA activation, but quantifying inter-atrial synchronization remains challenging. This study evaluated whether lead V8 reflects posterolateral LA activation time and whether lead V8 can be used to assess the effect of BBP on LA activation. Consecutive patients undergoing an electrophysiology study and ablation (Cohort 1) or BBP lead implantation (Cohort 2) were prospectively enrolled. Surface ECGs were recorded with the V5 electrode repositioned to the V8 location (2 cm below the inferior left scapula). LA activation was determined using the steepest negative downslope of the P-wave (NDAT-P-V8). Iso-V8 was defined as the time from P-wave onset to first positive deflection in lead V8. In Cohort 1, a coronary sinus (CS) catheter invasively determined activation timing at the posterolateral LA (mitral isthmus region). In Cohort 2, NDAT-P-V8 and iso-V8 were used to assess the effect of BBP on LA activation. In Cohort 1 (n=50), NDAT-P-V8 strongly correlated with the latest CS activation (r = 0.94, p<0.001). In Cohort 2 (n=50), lead V8 facilitated intra-procedural assessment of LA activation. IAB was corrected in 20/23 (87%), accompanied by shortening of NDAT-P-V8 (from 120±25ms to 82±17ms, p<0.001) and iso-V8 (from 51±22ms to 18±17ms, p<0.001), consistent with earlier LA activation. NDAT-P-V8 closely reflects the invasively determined timing of the posterolateral LA activation and provides a simple non-invasive marker to assess the effect of BBP on LA activation. Lead V8 may therefore help to assess and optimize atrial activation with BBP.
-
8. Safety and Efficacy of Left Atrial Ablation After Percutaneous Left Atrial Appendage Occlusion in High-Bleeding-Risk Patients with Atrial Fibrillation: A Multicenter Analysis from the PROCEED-AF Ablation Registry.
PMID:期刊:日期:2026-09-25Patients with left atrial appendage (LAAO) devices are increasingly referred for AF ablation, yet anticoagulation strategies remain uncertain. The goal of this study was to evaluate the safety and efficacy of catheter ablation for atrial fibrillation (AF) in patients with pre-existing LAAO devices and to describe patterns in anticoagulation management after ablation in this unique population. We collected data from 14 centers worldwide on patients with prior LAAO devices undergoing AF ablation. Each site provided clinical characteristics, procedural details, and information on complications and arrhythmia outcomes. Data were aggregated and analyzed centrally to evaluate procedural safety, efficacy, and variability in management strategies. A total of 198 patients (age 70 years, 37% female, 42% paroxysmal AF) with prior LAAO were included. Ablation was performed a median of 271 days after LAAO. After ablation, 84% of patients were on oral anticoagulation (OAC), most commonly for 2-3 months. Bleeding complications on OAC occurred in 6.7% of patients at a median of 20 (13, 70) days after ablation. Stroke or TIA occurred in 5 patients (2.6% of cases) within the follow-up period with 2 occurrences (1% of cases) the day after ablation. There were 2 cases of new or worsened peri-device leak after ablation. In a large, international registry of patients undergoing catheter ablation for AF with pre-existing LAAO devices, ablation was feasible and device related complications were rare Despite higher bleeding risk in an LAAO population, 84% of patients with prior LAAO tolerated short term OAC post-ablation with bleeding events at expected rates for this population.
-
9. Safety of Catheter Ablation for Atrial Fibrillation During Hospitalisation for Acute Heart Failure: A Nationwide Analysis From the JROAD-DPC Database.
9. 急性心力衰竭住院期间进行房颤导管消融的安全性:基于JROAD-DPC数据库的全国性分析PMID:期刊:日期:2026-09-23该文献暂无摘要。
-
10. Progressive Conduction System Disease Preceding Hypertrophy in IVS4 + 919G > A Fabry Variant: a Population-based Electrocardiographic Study.
10. 肥厚型心肌病IVS4 + 919G > A法布里变异型中,进行性传导系统疾病先于肥厚出现:一项基于人群的心电图研究PMID:期刊:日期:2026-09-22The IVS4 + 919G > A variant is the most prevalent late-onset Fabry variant in East Asian populations, but its electrophysiological trajectory remains incompletely defined. From a regional genetic screening program, 905 IVS4 + 919G > A carriers were identified among 457,581 patients and matched 1:2 to controls by age and sex. Electrocardiographic (ECG) parameters were compared across decades, and echocardiography correlated structural changes with ECG findings. The cumulative prevalence of IVS4 + 919G > A was 0.198%. Age-specific prevalence in females was ∼2.5-fold higher than in males (0.11-0.15%), without significant change throughout different age categories. Female carriers demonstrated the catch-up phenomenon after the age of 60. Males exhibited a 9-fold risk of right bundle branch block (RBBB) and pacemaker implantation (PPM) compared with male controls (RBBB, HR 9.286, 95% CI 5.16-16.70, P < 0.001; PPM, HR 9.197, 95% CI 2.88-29.31, P < 0.001), and this precedes the onset of echocardiographic left ventricular hypertrophy. Risk of stroke and atrial fibrillation (HR 1.435, 95% CI 0.69-2.96, P = 0.289) was similar between male carriers and controls. PR interval was not shortening and prolongs instead. Combining left ventricular hypertrophy with conduction abnormalities, ECG detection achieved 88% sensitivity, exceeding echocardiographic criteria alone (51.5%). IVS4 + 919G > A variant is characterized by a progressive electrical phenotype dominated by conduction system disease preceding hypertrophy without excess major arrhythmic events. Electrocardiographic surveillance and phenotype-based risk stratification may be more informative than structural assessment alone for identifying individuals at risk of device therapy.