ARTIFICIAL ORGANS人工器官
ARTIFICIAL ORGANS(英文缩写 ARTIF ORGANS),ISSN 0160-564X,eISSN 1525-1594,中文译名:人工器官 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.663 | Q3 |
| 2022 | 2.400 | Q3 |
| 2023 | 2.200 | Q3 |
| 2024 | 2.300 | Q2 |
| 2025 | 2.200 | Q2 |
ARTIFICIAL ORGANS 最新收录文献
-
1. Surrogate-Assisted Multi-Objective Optimization of an Axial-Flow Ventricular Assist Device Rotor Using CFD, Hybrid Surrogates, Sobol Analysis, and MOPSO.
PMID:日期:2026-10-04This study presents a surrogate-assisted workflow for multi-objective optimization of an axial-flow ventricular assist device (VAD) rotor using 4809 steady-state CFD simulations spanning six geometric variables. Repeated learning-curve analysis and blade-count-stratified Gaussian-process regression (GPR) assessed data efficiency and complemented tree-based surrogate models. Final selection retained GPR for pressure rise, torque, hemolysis index, platelet activation, and exposure time, and HistGradientBoosting for hydraulic efficiency and the low-shear fraction S < 50 Pa, with held-out R values of 0.968-1.000. Because hydraulic efficiency is derived from pressure rise and torque at the fixed operating condition, the primary MOPSO formulation used six objectives: maximizing pressure rise and S < 50 Pa while minimizing torque, hemolysis index, platelet activation, and exposure time; efficiency was retained as a secondary engineering metric. Ten independent MOPSO runs were pooled to characterize Pareto trade-offs, and five representative Pareto designs were re-evaluated by direct CFD. The balanced compromise used a 53.58° inlet blade angle, 20.93° outlet blade angle, three blades, a 0.222 mm clearance gap, 0.796 mm blade thickness, and a 20.00 mm rotor length. For the balanced compromise, mean surrogate-to-CFD relative error was 4.0%, with all individual errors below 10%. Relative to baseline, direct CFD confirmed reductions of 17.2% in torque, 55.6% in hemolysis index, 46.9% in platelet activation, and 27.0% in exposure time, together with a 4.5% increase in S < 50 Pa; pressure rise decreased by 22.4% and hydraulic efficiency changed by +0.7%. The workflow supports design-space screening, trade-off identification, and targeted CFD confirmation of candidate geometries.
-
2. Race Mismatch in Ex Vivo Lung Perfusion Is Not Associated With Worse Survival After Lung Transplantation.
PMID:日期:2026-10-04To meet the growing demand of donor lungs, ex vivo lung perfusion (EVLP) is being used to further assess higher risk donor lungs. This study aims to identify the association of race mismatch between donor and recipient on survival in lung transplantation with EVLP. The UNOS database was queried for all lung transplants evaluated with EVLP from 2/2018 to 3/2025. Recipients with age < 18, multi-organ transplants, re-transplants, or missing data were excluded. Transplants were stratified into those with race concordance (RC) and mismatch (RM) between recipients and donors. Kaplan-Meier methods with log-rank tests were used to assess survival differences. A multivariable cox regression model was created using select variables. 1246 lung transplant recipients were identified: 638 in the RC group, 608 in the RM group. RC recipients were predominantly White (92.2% vs. 55.9%), had higher incidence of former smoking history (63.2% vs. 54.3%), and lower lung allocation scores. RC donors were more frequently White (92.2% vs. 31.6%) and DCD (38.6% vs. 29.9%). Post-operative outcomes were similar between both RC and RM groups, only treated rejection in the first year was significantly higher in the former (p = 0.005). Unadjusted survival did not differ between the groups (p = 0.27). On multivariate cox-proportional hazard modeling, RM was not independently predictive of mortality (HR 1.16 95% CI: 0.92-1.46) while recipient ECMO was the strongest predictor of mortality (HR 2.68, 95% CI: 1.71-4.20). For recipients who underwent lung transplantation following EVLP, race mismatch was not independently associated with mortality on adjusted analysis.
-
3. The Anti-Inflammatory Effect of Normothermic Machine Perfused Human Kidneys on Monocyte-Derived Dendritic Cells.
PMID:日期:2026-09-30The immunomodulatory activity of normothermic machine perfusion (NMP) on donor organs may be reflected by the release of immune-regulating factors into the perfusate. Dendritic cells (DCs) are potent antigen-presenting cells and are able to sense these factors. We hypothesized that activation of DCs could be used to monitor the release of these mediators into the perfusate. Human monocytes from buffy coats were differentiated into monocyte-derived DCs (moDCs). Perfusate was obtained from human donor kidneys deemed unsuitable for transplantation (n = 15) that underwent 6 h of NMP. MoDCs were incubated for 24 h with perfusate collected at different timepoints. DC supernatant was analyzed with Luminex and ELISA. MoDCs were analyzed with flow cytometry for maturation markers and co-cultured with allogenic T cells. Incubation with perfusate resulted in moDCs with a reduced surface expression of CD86, without affecting other maturation markers. Analysis of DC supernatant showed there was a specific increase of IL-10 production upon incubation with perfusate. As a consequence, moDCs incubated with perfusate showed lower T cell stimulatory capacity. This study showed that the activation status of DCs can be used to monitor the release of factors into the perfusate during NMP with an anti-inflammatory DC phenotype and function. It demonstrates the feasibility of a cell-based model to determine immune regulatory effects during ex vivo organ perfusion.
-
4. Engineering an Implantable Bioartificial Pancreas to Balance Transport, Containment, and Retrieval.
PMID:日期:2026-09-24An implantable bioartificial pancreas must accommodate a therapeutically meaningful cell dose while simultaneously maintaining oxygen and nutrient transport, glucose-responsive insulin secretion, immune protection, cellular containment, mechanical integrity, and surgical retrievability. Although promising results have been obtained in preclinical models, these advances have not consistently translated into clinically meaningful endocrine function. This narrative review integrates experimental, computational, preclinical, and clinical evidence relevant to implantable bioartificial pancreas design. Particular attention is given to the coupled effects of cell size and loading density, membrane and device geometry, oxygen supply, vascular proximity, extracellular matrix, foreign-body response, mechanical integrity, containment, and retrieval. Published quantitative examples are distinguished from model assumptions, illustrative calculations, and proposed engineering criteria. Available evidence indicates that device performance is governed by interacting rather than independent constraints. Increasing cell loading can compromise oxygenation, whereas reducing diffusion distance may increase device footprint or complicate retrieval. Cell-excluding membranes do not necessarily prevent soluble inflammatory injury, and improved oxygenation can introduce additional maintenance requirements and failure modes. Clinical experience further shows that cell survival alone does not ensure therapeutically meaningful insulin secretion. Accordingly, dynamic transport testing, containment assessment, hydrated mechanical testing, host-response evaluation, and planned retrieval should be evaluated within the same device configuration. Progress toward a clinically useful bioartificial pancreas requires reproducible endocrine function at a surgically manageable scale, explicit evaluation of soluble immune injury and oxygen-support failure, and documented complete retrieval. Configuration-matched testing and predefined engineering benchmarks may improve interpretation of both successful and unsuccessful implant studies.
-
5. A New Double Uniform Radial Clamping Artificial Anal Sphincter Device.
PMID:日期:2026-09-21Artificial anal sphincters are an important option for patients with severe anal incontinence. However, existing artificial anal sphincters still present safety and effectiveness concerns in animal experiments and clinical applications. Based on these problems, a novel double uniform radial clamping artificial anal sphincter device was proposed. In this study, a novel double uniform radial clamping artificial anal sphincter device was designed. The constant-force characteristics of the device and its mechanical interaction with intestinal tissue were evaluated using finite element analysis. The simulation results showed that the maximum equivalent stresses on the outer and inner surfaces of the intestinal wall were approximately 147 and 159 kPa, respectively. Regions of elevated equivalent stress were mainly localized near the bilateral clamping regions. The reaction force of the shape memory alloy constant-force mechanism reached a peak value of 6.23 N at a displacement of 2.48 mm. Over the displacement range of 3.25-6.35 mm, the reaction force remained between 5.78 and 6.07 N, with a mean value of approximately 5.89 N, indicating an approximately constant-force plateau. The proposed artificial anal sphincter provides a novel double uniform radial clamping design. Finite element analysis characterized the local mechanical response of the intestinal wall and the constant-force behavior of the device, providing preliminary mechanical information for further experimental optimization and in vivo validation.
-
6. Decellularized Fetal Porcine Dermis as a Substrate for Skin Models.
PMID:日期:2026-09-21Human skin is mainly composed of an epidermal layer of stratified keratinocytes and a dermal layer containing fibroblasts and extracellular matrix (ECM). Epidermal-dermal models that replicate both the epidermis and dermis are widely used for skin evaluation. However, it remains challenging to reproduce the complex dermal ECM using artificial materials. Although decellularized dermis from human and animal sources is composed of dermal ECM, its application as a substrate for skin models has not progressed due to the difficulty of recellularization in vitro. We previously reported that cells are more likely to infiltrate into decellularized fetal porcine bone marrow than decellularized adult porcine bone marrow. In the present study, we developed a skin model by seeding human fibroblasts and keratinocytes onto a decellularized fetal porcine dermis (dFPDe). Fibroblasts infiltrated into the dFPDe and keratinocytes formed a stratified epidermal layer on its surface. The compressive elastic modulus and permeability of the dFPDe-based skin model were similar to those of human skin. These results suggest that dFPDe could be a useful substrate for the development of physiological skin models.
-
7. Repeat Impella 5.5 During Single Hospitalization: A Single Center Experience.
PMID:日期:2026-09-21The Impella 5.5 device is a temporary mechanical circulatory support device widely used in patients with refractory cardiogenic shock. However, device-related or device-associated complications, as well as recurrent cardiogenic shock after device removal, may necessitate repeat implantation during the same hospitalization. Out of 579 who underwent Impella 5.5 implantation at our institution between January 2020 and 2026, we reviewed the 14 patients who required repeated insertion during a single hospitalization. Indications for repeat implantation were categorized as device-related failure or physiologic deterioration. The primary outcome was survival to hospital discharge. Secondary outcomes included stroke, surgical-site infection, and access-site bleeding. Patients had a median age of 57 years, and 79% were male. Indications for repeat implantation were device-related failure in 57% (8/14) and physiologic deterioration in 43% (6/14). Median interval between devices was 10.5 days (IQR, 6-22). Repeat implantation was performed through the same axillary access site in 57% (8/14) and a new access site in 43% (6/14). After initial device insertion, 50% required VA-ECMO and 28%. Survival to hospital discharge was 71% (10/14); however, post-reimplantation complications were frequent, with stroke and access-site bleeding each occurring in 29% of patients and surgical-site infection in 7%. Five patients (36%) underwent durable LVAD implantation and 5 (36%) underwent heart or heart-kidney transplantation. Repeat Impella 5.5 implantation during a single hospitalization was uncommon and was performed in a highly selected cohort with favorable survival outcomes, although accompanied by a substantial rate of neurological and local bleeding complications. These descriptive findings should be interpreted in the context of substantial selection bias, small sample size, and single-center experience.
-
8. Synthetic Biology and Soft Robotics in Biohybrid Kidney Replacement: A Conceptual Framework and Translational Roadmap.
8. 合成生物学与软体机器人在生物混合肾脏替代中的应用:概念框架与转化路线图PMID:日期:2026-09-20Chronic kidney disease necessitates safer, more continuous kidney replacement therapies (KRT), yet current dialysis and transplantation are constrained by intermittent treatment, organ scarcity, and immunosuppression-related complications. This conceptual narrative review examines the potential integration of synthetic biology and soft robotics within a biohybrid KRT framework. We define a cyborg nephron as an engineered functional unit coupling living renal/vascular cells with compliant mechanical and fluidic interfaces, organized as a Modular Renal Assist Device (MRAD) with separable filtration, tubular transport, endocrine support, and control modules. Technology readiness levels (TRL) were applied to distinguish established, preclinical, and conceptual components. Available evidence supports several individual components including cell-based renal bioreactors, microphysiological models, endothelialized blood-contacting surfaces, passive membranes, soft micropumps, and wireless sensing (TRL 3-5). Conversely, autonomous renal gene circuits, active immunoisolation, durable vascular integration, and fully implanted closed-loop control remain predominantly preclinical or conceptual (TRL 1-2). Major barriers include thrombosis, oxygen delivery, cell maturation, genetic stability, mechanical fatigue, power demands, cybersecurity, and regulation of combined living-device products. The cyborg nephron represents a hypothesis-generating research framework rather than a near-term clinical solution. Staged validation through modular development, conservative safety design, and comparison with simpler alternatives is essential before integrated preclinical testing can be justified.
-
9. Disease-Specific Ventricular Unloading Responses to Impella Support Revealed by Three-Dimensional Pressure-Volume-Flow Landscape Analysis.
PMID:日期:2026-09-20Impella support alters left ventricular pressure-volume (PV) relations, but disease-specific unloading responses across the full support range remain incompletely characterized. We developed a three-dimensional pressure-volume-flow landscape (3D-PVL) framework to quantify and compare ventricular unloading in acute myocardial infarction (AMI), dilated cardiomyopathy (DCM), and DCM with mitral regurgitation (DCM + MR). PV loops were simulated using a closed-loop cardiovascular model at 51 Impella-flow levels from 0 to 5.0 L/min. Loop-centroid displacement and stroke work were normalized to their respective 0-L/min values, and their unscaled direction-sensitive derivatives were combined into a composite response. The response index (RI) quantified integrated response magnitude, while interior peak-response flow (Qpeak) identified the flow level of maximal incremental response among interior flow points. Pressure-volume area (PVA) provided energetic validation. Unloading trajectories differed among disease states despite baseline normalization. Integrated response magnitudes were similar across the three disease models (RI: 1.33, 1.37, and 1.35 for AMI, DCM, and DCM + MR, respectively), whereas interior Qpeak differed at 3.40, 2.90, and 2.70 L/min. DCM + MR showed a renewed response increase at high flow, with its overall maximum occurring at the 5.0-L/min boundary. PVA-based analysis preserved the higher-flow response peak in AMI (3.60 vs. 3.10 and 2.90 L/min in DCM and DCM + MR). The underlying disease substrate influenced the distribution of ventricular unloading across the Impella-flow range despite similar integrated response magnitudes. The 3D-PVL framework provides quantitative descriptors of disease-specific unloading trajectories rather than clinically validated therapeutic targets.
-
10. Engineering Immune-Protective Stem Cell-Derived β-Cell Grafts for Type 1 Diabetes: Encapsulation Technologies and the Emerging Graft Ecosystem.
PMID:日期:2026-09-16Stem cell-derived β-cell replacement has emerged as a promising strategy for the treatment of type 1 diabetes (T1D), potentially addressing the limitations of exogenous insulin therapy and donor-dependent islet transplantation. However, despite substantial progress in stem cell differentiation and transplantation technologies, long-term graft survival remains constrained by immune rejection, recurrent autoimmunity, fibrosis, hypoxia, and inadequate vascularization. Encapsulation technologies have therefore become central to the development of clinically viable bioartificial pancreas systems. This review examines advances in stem cell-derived β-cell replacement, with particular emphasis on encapsulation technologies and their translational challenges. Major stem cell sources, including embryonic stem cells and induced pluripotent stem cells, contemporary differentiation strategies, and clinical progress were evaluated. Microencapsulation, macroencapsulation, and conformal coating approaches were critically considered with respect to immunoprotection, mass transport, retrievability, and long-term graft functionality. Biological barriers and emerging engineering strategies were further integrated within a unified mechanistic framework. Current evidence indicates that successful long-term β-cell replacement is limited not only by immune-mediated injury but also by foreign body responses, pericapsular fibrosis, hypoxia, inadequate vascular integration, and compromised mass transport. Emerging approaches, including oxygen-generating biomaterials, immunomodulatory encapsulation systems, vascularization-promoting platforms, smart responsive biomaterials, and gene-edited hypoimmune β-cells, are being developed to overcome these barriers. Collectively, these advances indicate that durable graft function requires coordinated regulation of immunity, oxygenation, vascularization, and tissue homeostasis rather than the generation of functional insulin-producing cells alone. Durable β-cell replacement for T1D will likely require engineering a supportive graft ecosystem rather than focusing exclusively on cell replacement. The field is consequently transitioning from cell replacement engineering toward graft ecosystem engineering, in which stem-cell engineering, biomaterials science, immune modulation, vascularization strategies, and biosensing technologies are integrated to create clinically scalable and durable therapeutic platforms.