Diabetes Technology & Therapeutics糖尿病技术与治疗
Diabetes Technology & Therapeutics(英文缩写 DIABETES TECHNOL THE),ISSN 1520-9156,eISSN 1557-8593,中文译名:糖尿病技术与治疗 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 7.337 | Q1 |
| 2022 | 5.400 | Q1 |
| 2023 | 5.700 | Q1 |
| 2024 | 6.300 | Q1 |
| 2025 | 7.400 | Q1 |
Diabetes Technology & Therapeutics 最新收录文献
-
1. Factors Associated with Utilization and Underutilization of Diabetes Technology in Underrepresented Families Living with Type 1 Diabetes.
1. 少数族裔1型糖尿病家庭中糖尿病技术使用与未充分利用的相关因素PMID:日期:2026-09-25Continuous glucose monitoring (CGM) and insulin pumps improve glycemic outcomes and quality of life for youth with type 1 diabetes, yet utilization remains suboptimal. We analyzed cross-sectional data from 84 parent-youth dyads in the Building the Evidence to Address Disparities in Type 1 Diabetes study. Youth using both CGM and pump were classified as technology utilizers. Adjusted prevalence ratios (aPR) evaluated associations of sociodemographic variables with utilization. Parents of utilizers were older (standardized mean difference [SMD] = 0.74), had higher education (SMD = 0.91), and youth had longer diabetes duration (SMD = 0.49). Underutilizers endorsed higher youth discrimination (4.23 vs 2.49, = 0.016) and greater CGM-burden (2.34 vs 1.84, < 0.001), while technology acceptance was higher among utilizers (4.40 vs 3.91, = 0.007). Parental age (aPR = 1.03, 95% CI: [1.01,1.05], = 0.003), parental education (aPR = 1.10, 95% CI: [1.01,1.19], = 0.03), and Non-White + non-English caregivers (aPR = 1.58, 95% CI: [1.01,2.48], = 0.046) were associated with higher utilization. Youth discrimination (aPR = 0.94, 95% CI: [0.89,1.00], = 0.04) was associated with lower utilization. Technology utilization was associated with structural characteristics and youth-reported experiences, with youth discrimination identifying experiential factors that may influence adoption of diabetes technologies.
-
2. Continuous Glucose Monitoring and Hospitalization Outcomes in Adults with Insulin-Treated Type 2 Diabetes and Complex Care Needs: A Population-Based Study.
PMID:日期:2026-09-24Continuous glucose monitoring (CGM) improves glycemic outcomes in insulin-treated type 2 diabetes (T2D), but evidence in individuals with complex care needs (CCN) is limited. We evaluated the association between CGM initiation and hospitalization outcomes in a population-based cohort of adults with insulin-treated T2D and CCN. We conducted a population-based quasi-experimental study including all eligible adults with insulin-treated T2D and CCN who initiated CGM through the Andalusian Public Health System. Rates of acute diabetes-related complications and cardiovascular admissions were compared before and after CGM initiation using Poisson regression models adjusted for person-time. Interrupted time-series analyses, length of stay (LOS), and hospitalization costs were also evaluated. Of 17,561 adults initiating CGM, 5281 met criteria for CCN and were included (mean age 79 years; 55.1% aged ≥ 80 years). Acute diabetes-related hospitalization rates decreased from 144.27 to 41.04 per 10,000 person-years (rate ratio [RR] 0.28, 95% CI 0.19-0.42), and cardiovascular admission rates decreased from 387.25 to 251.96 per 10,000 person-years (RR 0.65, 95% CI 0.54-0.78). Interrupted time-series analyses showed post-intervention hospitalization rates consistently below counterfactual estimates. Mean LOS decreased by 3.68 days (95% CI -5.26 to -2.10; < 0.001), and hospitalization costs decreased by USD657.39 per patient-year. In this population-based cohort of adults with insulin-treated T2D and CCN, CGM initiation was associated with fewer hospitalizations, shorter hospital stays, and lower hospitalization costs, supporting the integration of diabetes technology into chronic care strategies for highly vulnerable populations.
-
3. Three-Year Real-World Performance of Bihormonal Fully Closed-Loop Therapy in Type 1 Diabetes.
3. 双激素全闭环疗法治疗1型糖尿病的三年真实世界性能研究PMID:日期:2026-09-24Type 1 diabetes management continues to advance through novel treatment options, such as bihormonal fully closed-loop (FCL) systems. Real-world data on these systems are currently limited to a maximum of 1 year. Extended follow-up spanning several years would provide valuable insights into long-term performance of a bihormonal FCL. In a retrospective, observational, real-world cohort study, adults with type 1 diabetes who were treated with the bihormonal FCL system for 3 years were included. Endpoints were determined per 6 months (semester) and included continuous glucose monitoring-derived outcomes. Linear mixed-effects models were used to evaluate changes in outcome measures over time. A total of 102 users were included in the study. Limited availability of initial glucagon (GlucaGen [GG]) led to a necessary switch to an alternative (Glugon) for a part of the users. GG-only users ( = 60) demonstrated stable glucose outcomes over the 3-year period, whereas a decline was observed in the total group during the final period. In the GG-only group, time in range (TIR; 3.9-10.0 mmol/L [70-180 mg/dL]) ranged from 79.5% to 80.8% and from 77.4% to 80.8% in the total group. For time below range (<3.9 mmol/L [<70 mg/dL]), this was 0.95%-1.56% (GG-only) versus 1.03%-1.69% (total). TIR decreased from 79.3 ± 7.1 to 75.8 ± 7.9 in the 3-month period after the glucagon switch compared to the period before ( < 0.001). Real-world data demonstrated long-term stability of bihormonal FCL system performance among individuals treated with GG. A slight decline in performance was observed in the total population, and outcomes significantly deteriorated for users after the glucagon switch, indicating a negative effect on FCL performance of the alternative glucagon. Overall, the long-term findings point toward the benefits of the bihormonal FCL to maintain adequate glycemic control in people with type 1 diabetes over several years.
-
4. {"_":"Sustained Glycemic Outcomes with the MiniMed 780G System: Real-World Evidence from >16,000 Users Across 18 Latin American Countries Over Two Years.","sup":["™"]}
4. MiniMed 780G系统维持血糖控制效果:来自18个拉丁美洲国家超过16,000名用户两年以上的真实世界证据PMID:日期:2026-09-19Automated insulin delivery (AID) systems achieve consistent glycemic outcomes in real-world settings, yet access across Latin America (LATAM) remains critically low, with marked disparities driven by demographic, structural, and health care infrastructure heterogeneity across the region. This study characterizes the real-world performance of the MiniMed™ 780G (MM780G) advanced hybrid closed-loop (AHCL) system across 18 LATAM countries and evaluates the durability of glycemic outcomes over 24 months. Data from 16,669 individuals with type 1 diabetes using the MM780G system across 18 LATAM countries (January 2020-October 2025) were analyzed; 27.1% were pediatric (<16 years) and 70.8% adult (≥16 years). Primary outcomes included time in range (TIR), time in tight range (TITR), glucose management indicator (GMI), and time below range (TBR), stratified by age, sex, country, and recommended optimal settings (ROS: glucose target 100 mg/dL, active insulin time 2 h, ≥95% of time). A longitudinal sub-analysis followed 1204 users across 24 consecutive monthly time points. Overall, mean TIR was 73.4% and GMI 6.9%, with TBR within consensus targets; approximately two-thirds of users achieved TIR > 70% and GMI < 7.0%. ROS was adopted by 19.2% of users, which was associated with substantially improved outcomes, with mean TIR 77.5%, TIR > 70% attainment occurred in 83.9% of users, and composite target of GMI < 7, TIR > 70, TB70 < 4 and TB54 < 1 attainment rising to 66.4%. Pediatric users met or exceeded (with ROS) the internationally recommended 70%TIR threshold (mean overall TIR 70.0% and 74.2% with ROS), while adults (mean TIR 74.6%) aligned closely with US and Europe, Middle East and Africa real-world benchmarks. TITR exceeded 50% in adults (50.3% overall and 54.1% with ROS) and exceeded the International Society for Pediatric and Adolescent Diabetes (ISPAD) 2024 recommended threshold of 50% in pediatric users (mean TITR 51.2% with ROS). Outcomes were consistent across sex and all five national cohorts. In the 24-month longitudinal sub-analysis, TIR remained clinically stable within one and a half percentage points throughout both age groups. The MiniMed™ 780G AHCL system delivered consistent and durable glycemic control over 24 months across the full demographic and structural heterogeneity of Latin America. Performance was aligned with internationally recommended consensus targets and was independent of age, sex, country, and health care infrastructure. Eliminating barriers to AID access is an immediate and achievable priority in the region and may improve the health of hundreds of thousands of people with diabetes in Latin America.
-
5. Association Between Continuous Glucose Monitoring Utilization and Glucagon-Like Peptide-1 Receptor Agonist Discontinuation in Type 2 Diabetes: A Real-World Study.
5. 连续血糖监测使用与2型糖尿病患者胰高血糖素样肽-1受体激动剂停药之间的关联:一项真实世界研究PMID:日期:2026-09-19Continuous glucose monitoring (CGM) and glucagon-like peptide-1 receptor agonists (GLP-1 RAs) when used jointly are associated with significant improvement in glycemic outcomes. However, it is unknown if using CGM enhances GLP-1 RA continuation. This study assesses the relationship between adherent CGM utilization and GLP-1 RA adherence among people living with type 2 diabetes (T2D) on nonintensive therapy. This retrospective matched-cohort study analyzed data from Inovalon Insights administrative claims from March 1, 2017, to April 30, 2024, for adults aged ≥18 years diagnosed with T2D, treated with basal insulin or noninsulin therapy, and CGM-naïve before starting GLP-1 RA. Adherent CGM utilization was defined as having a proportion of days covered (PDC) ≥0.8 within 1-year post GLP-1 RA initiation. CGM users were matched with non-CGM users based on age, sex, race/ethnicity, basal insulin/noninsulin therapy, GLP-1 RA type, comorbidities, insurance type, and one fill/multiple refills of GLP-1 RA. The primary outcome was GLP-1 RA discontinuation over the 12-month observation period, which was defined as the first gap of ≥90 days without GLP-1 RA supply post-index. Kaplan-Meier model was used to estimate the time to discontinuation, and hazard ratios (HRs) were calculated using a multivariable Cox proportional hazards regression model. The study included 934 adherent CGM users matched with 3747 non-CGM users. One year post GLP-1 RA initiation, 68.4% (95% confidence interval [CI]: 65.5%-71.5%) of adherent CGM users remained on GLP-1 RA compared with 51.9% (95% CI: 50.3%-53.5%) of non-CGM users ( < 0.001). After adjusting for covariates, adherent CGM users were significantly less likely to discontinue GLP-1 RA compared to non-CGM users (HR: 0.56 [95% CI: 0.49-0.63], < 0.001). This study suggests that adherent CGM utilization is associated with a significantly lower risk of GLP-1 RA discontinuation and may potentially enhance adherence to GLP-1 RA medication in people living with T2D on nonintensive therapy.
-
6. Use of Continuous Glucose Monitoring Indicators to Guide Dose Titration of Weekly Basal Insulin Efsitora Alfa in Insulin-Naive and Basal Insulin-Experienced Adults with Type 2 Diabetes: A Retrospective Analysis.
6. 使用连续血糖监测指标指导每周基础胰岛素Efsitora Alfa在未使用过胰岛素及已使用基础胰岛素的2型糖尿病成人患者中的剂量滴定:一项回顾性分析PMID:日期:2026-09-17Basal insulin dose titration has historically relied on fasting self-monitoring blood glucose (SMBG) and hypoglycemic events. This retrospective analysis of the QWINT-2 and QWINT-3 Phase 3 trials aimed to evaluate the use of continuous glucose monitoring (CGM)-derived indicators for weekly insulin efsitora alfa (efsitora) titration in insulin-naive and basal insulin-experienced adults with type 2 diabetes (T2D) through dose-to-dose comparisons with self-monitoring fasting plasma glucose (FPG) and CGM-derived hypoglycemic events, and by assessing concordance between CGM fasting indicators and FPG independent of insulin dose adjustment. CGM and self-monitoring FPG data from QWINT-2 (insulin-naive, = 466) and QWINT-3 (basal insulin-experienced, = 655) efsitora-treated participants were analyzed. CGM fasting indicators were compared with FPG through weekly dose-to-dose titration decisions following the SMBG-based Phase 3 trial dose titration algorithm, and by assessing concordance between CGM fasting indicator and FPG values. CGM hypoglycemia indicators were assessed weekly for agreement with CGM-derived hypoglycemic events below 70 mg/dL and 54 mg/dL following the SMBG-based Phase 3 trial hypoglycemia criteria. User burden was considered, with low burden meaning a CGM indicator was readily available in an ambulatory glucose profile (AGP) report. CGM hypoglycemia indicators demonstrated 91.5%-98.3% agreement with CGM-derived hypoglycemic events in QWINT-2 and QWINT-3. CGM fasting indicators "Lowest median of AGP," and "Typical fasting 25% from AGP" demonstrated clinical equivalency with FPG, with dose differences within 20 weekly units for 90.7%-93.4% of dose decisions for both studies. In insulin-naive and basal insulin-experienced populations treated with weekly efsitora, CGM indicators of hypoglycemia and fasting glucose yielded clinically equivalent dose titration decisions as CGM-derived hypoglycemic events and self-monitoring FPG, respectively. These findings support translation of established titration practices to a CGM-based workflow in insulin-naive and basal insulin-experienced adults with T2D, consistent with recommendations for CGM use in adults with diabetes on insulin therapy.
-
7. Continuous Glucose Monitoring Hypoglycemia Alarms in Critical Care: Clinical Utility and Workflow Integration.
7. 重症监护中的持续葡萄糖监测低血糖警报:临床实用性与工作流程整合PMID:日期:2026-09-16Continuous glucose monitoring (CGM) has been associated with reductions in inpatient hypoglycemia; however, little is known about the performance and integration of CGM hypoglycemia alerts and alarms in the intensive care unit (ICU). We evaluated hypoglycemia signal frequency, clinical response, and contributing factors within an ICU implementation study. This prespecified secondary analysis was conducted within a prospective hybrid effectiveness-implementation study of adults in a medical ICU. Hypoglycemia signals included low alerts (<100 mg/dL), urgent low soon alerts, and urgent low alarms (<55 mg/dL). Signal frequency, progression to hypoglycemia <70 mg/dL, nursing response times, and protocol fidelity were evaluated. Consecutive signals occurring within 15 min were clustered into signal events. Confirmatory point-of-care (POC) glucose response time was calculated from the initial signal to the first subsequent POC measurement. All POC-confirmed hypoglycemic events (<70 mg/dL) underwent structured multidisciplinary root cause review. Among 100 participants, 60% experienced at least one hypoglycemia signal, generating 1060 signals (3.6 ± 6.8 signals/patient-day) that clustered into 378 signal events. Fifty-one percent of signal events remained between 80 and 100 mg/dL, without falling below the institutional treatment threshold (<80 mg/dL). Ninety-five percent of urgent low alarms were preceded by an urgent low soon alert, a mean of 10.0 ± 7.8 min earlier. Median confirmatory POC response time was 33 min (interquartile range 12-51) and was significantly faster for lower glucose values and validated CGM signals. All, but one hypoglycemic event, were preceded by a validated CGM hypoglycemia signal. Case review identified intravenous insulin, carbohydrate coverage, and enteral feed-related factors as the most common contributors to hypoglycemia. CGM hypoglycemia signaling integrated into ICU workflows can provide advance warning before hypoglycemic events while maintaining a modest contribution to alarm burden. Signal characteristics influenced nursing response, supporting further optimization of inpatient CGM alarm thresholds and implementation strategies. ClinicalTrials.gov NCT#05571397 https://clinicaltrials.gov/study/NCT05571397.
-
8. Long-Term Clinical and Economic Impact of Automated Insulin Delivery Systems Use in Pediatric and Adolescents Type 1 Diabetes: Results Across Australia, Canada, the UK, and the USA.
PMID:日期:2026-09-10Automated Insulin Delivery (AID) systems are the recommended standard of care for Type 1 Diabetes (T1D) management in children and adolescents, according to latest international guidelines. This study aims to assess the cost-effectiveness of AID systems for pediatric T1D care in Australia, Canada, the United Kingdom (UK), and the United States (USA). The IQVIA Core Diabetes Model was used to compare AID systems with Multiple Daily Injections and Continuous Glucose Monitoring (MDI+CGM). Data were sourced from the National Health System (NHS England real-world AID pilot initiative, a prospective follow-up study of 251 children and adolescents with T1D that showed a 0.63% reduction in HbA1c following the first year of system use. Clinical and economic outcomes were analyzed over a 55-year time horizon from a health care system perspective, applying country-specific discount rates and direct costs to estimate cost-effectiveness ratios (ICERs). AID systems were associated with Quality-Adjusted Life Years (QALYs) gains ranging from 1.35 to 2.72 across all countries. AID use resulted in significant relative risk reduction for long-term complications, such as proliferative diabetic retinopathy (51.3%), end-stage renal disease (39.5%), and severe vision loss (38.8%). Total cost savings ranged from USD-9340 in Australia to USD-28,798 in Canada. AID use was associated with an ICER of 14,590 in Australia, 25,798 in Canada, 32,459 in the UK, and 35,648 in USA per QALY gained (all values in USD). AID therapy was predicted to reduce mid- and long-term diabetes-related complications and improve quality of life while concomitantly reducing the economic burden on health care systems. AID was projected to be cost-effective versus MDI+CGM for pediatrics and adolescents with T1D in all analyzed countries. These findings highlight the need to accelerate the adoption of AID systems and to secure universal access and funding during this vulnerable period of life.
-
9. Pediatric Inpatient Continuous Glucose Monitor Accuracy by Sensor Wear Day, Hospital Day, and Glucose Rate of Change.
9. 儿科住院患者持续葡萄糖监测仪准确性:按传感器佩戴天数、住院天数和葡萄糖变化率分析PMID:日期:2026-09-10Continuous glucose monitoring (CGM) improves glycemic outcomes but inpatient use in the United States is not FDA approved, despite the potential need for frequent glycemic monitoring during hospitalization. We sought to assess CGM accuracy in the pediatric hospital setting and to evaluate the impact of potential modifiers of accuracy, including sensor wear day, hospitalization day, and glucose changes. In this retrospective cross-sectional accuracy study among youth and young adults with diabetes hospitalized at two pediatric centers, reference point-of-care (POC) capillary glucose values were compared with Dexcom G7 CGM glucose readings (paired within 5 min). Accuracy was assessed using standard metrics, including mean absolute relative difference (MARD) and Parkes error grids, overall, and stratified by sensor wear day, hospital day, and CGM glucose rate of change. We analyzed 544 POC-CGM glucose pairs from 68 participants with diabetes aged 2-22 years (mean 12.4 ± 5.8 years old, 58.8% female, 66.2% White, 8.8% Hispanic) during 80 hospital encounters. The overall MARD was 12.5%. Accuracy was comparable on sensor wear day 1 and days 2-6 (MARD 12.3% vs 13.6%, respectively) and was best on wear days 7-10 (MARD 10.6%). Accuracy improved from hospital day 1 (MARD 13.7%) to hospital days 2-4 and 5-30 (MARD 10.4% and 12.5%, respectively). Overall and on wear day 1, almost all glucose pairs (99%) fell within low-risk Parkes error grid zones A and B. Accuracy was best with a flat [-1 to 1 mg/(dL·min)] rate of change (MARD 11.5%-11.9%) and was reduced with rapidly rising or falling [beyond -2 or 2 mg/(dL·min)] CGM values (MARD 16.6%-18.4%). In this pediatric hospital CGM accuracy study, MARD was within a favorable range of <14% overall and throughout sensor wear and hospitalization. Reduced accuracy with rapidly changing glucose highlights the need to incorporate trend arrows into hospital CGM protocols.
-
10. Real-Time Continuous Glucose Monitoring Improves Glycemic Control in the Early Postoperative Period Following Liver Transplantation: A Randomized Controlled Trial.
10. 实时连续血糖监测改善肝移植术后早期血糖控制:一项随机对照试验PMID:日期:2026-08-24Early postoperative glycemic control after orthotopic liver transplantation (OLTx) is challenging because of surgical stress, corticosteroid and calcineurin-inhibitor immunosuppression, and parenteral nutrition. We evaluated whether adding real-time continuous glucose monitoring (rtCGM) to standard care increases time in the target glucose range. In this single-center randomized controlled trial, OLTx recipients were randomized after surgery to open (Active) or blinded (Control) rtCGM (Dexcom G6); in the Active group, sensor data guided insulin titration. The primary endpoint was time in target range (TIR, 6.0-10.0 mmol/L), analyzed in a modified intention-to-treat population. Secondary endpoints included glycemic metrics, insulin requirements, and predefined clinical outcomes. We randomized 154 patients; 142 with available data were analyzed (82 Active, 60 Control). The Active group spent more time in target range (68.9% vs. 60.8%; median difference 7.2 percentage points [95% CI: 2.7-12.0]; = 0.003), with less time in Level 1 hyperglycemia ( = 0.025) and fewer extended hyperglycemic episodes (incidence rate ratio 1.65 [1.03-2.65] for Control vs. Active; = 0.039). TIR improved similarly in patients with and without pretransplant diabetes; the only significant treatment-by-diabetes interaction was a greater reduction in Level 2 hyperglycemia among patients with diabetes ( < 0.001). Hypoglycemia was minimal in both groups. Infectious complications were less frequent in the Active group (45.1% vs. 63.3%; = 0.041). Adding rtCGM to standard postoperative care improved glycemic control after liver transplantation, with consistent benefit regardless of diabetes status and the greatest effect on Level 2 hyperglycemia in patients with diabetes. The lower infection rate is a hypothesis-generating finding warranting a dedicated trial.