MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES微创治疗与相关技术
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES(英文缩写 MINIM INVASIV THER),ISSN 1364-5706,eISSN 1365-2931,中文译名:微创治疗与相关技术 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.179 | Q3 |
| 2022 | 1.700 | Q3 |
| 2023 | 1.700 | Q2 |
| 2024 | 2.000 | Q2 |
| 2025 | 1.800 | Q2 |
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES 最新收录文献
-
1. Surgical telementoring platforms for clinical care and training: a systematic review.
PMID:期刊:日期:2026-09-24Surgical telementoring enables remote, real-time expert guidance in clinical practice and surgical education. This systematic review evaluated telementoring platforms used in surgery and training, focusing on technical characteristics, applications, strengths, and limitations. PubMed/MEDLINE, Scopus, and Web of Science were searched for studies published from January 2015 to April 15, 2026, following PRISMA 2020. Eligible studies described surgical telementoring platforms with sufficient technical and application-related information. Findings were narratively synthesized into clinical practice, training/simulation, and immersive/augmented applications. Quality was assessed using the Mixed Methods Appraisal Tool. The review was registered in PROSPERO (CRD420261403771). The search identified 672 records, 35 reports representing 34 independent studies from 18 countries were included. Most were feasibility, pilot, simulation, or early implementation studies. Platforms ranged from low-cost audiovisual systems to integrated immersive technologies. Clinical studies mainly demonstrated technical feasibility, while comparative evidence on patient outcomes and safety remained limited. Training studies reported improved procedural performance and learner confidence, while immersive systems showed potential for enhanced spatial guidance. Surgical telementoring is feasible across clinical and educational settings, but evidence regarding patient outcomes and comparative safety remains limited. Future research should prioritize standardized reporting, comparative clinical validation, governance frameworks, and integration into structured training pathways.
-
2. PaceyCuff for male stress urinary incontinence: first UK pilot evaluation of clinical outcomes and short-term cost offset.
2. PaceyCuff用于男性压力性尿失禁:英国首次临床结局及短期成本抵消的初步评估PMID:期刊:日期:2026-09-23Incontinence pads are the standard treatment for male stress urinary incontinence (SUI), especially after prostate surgery. Implantable devices are effective but limited by surgical waitlists and patient suitability. The PaceyCuff is a novel external urethral control device designed for extended wear while aiming to preserve blood flow, offering a less invasive option than surgery. This UK pilot study assessed preliminary clinical outcomes, tolerability, patient satisfaction, and short-term cost-offset observations. Sixteen participants were enrolled. Two were excluded from the final analysis: one due to unrelated death and another due to inability to wear the PaceyCuff due to a buried penis. Baseline penile and finger peripheral oxygen saturation (SpO), 3-h pad weight, 24-h pad count and patient-reported outcomes using the International Consultation on Incontinence Questionnaire-Urinary Incontinence (ICIQ-UI) and Quality of life questionnaire (QoL) were recorded. Participants were fitted with the PaceyCuff, and reassessed immediately, at 3 h and ( telephone) at two weeks and one month. ICIQ-UI scores fell from 17.4 to 7.2 at one month; QoL improved from 12.5 to 2.9. Urine loss decreased from 94 g to 10 g ( = .014). Pad use dropped from 4.2 to 1.7/day. Mean pain score 1.9/10, with two minor adverse events. Penile SpO remained stable, with no short-term clinical signs of ischaemia observed. The mean Charlson Comorbidity Index was 6.1. Weekly pad costs decreased from £42.34 to £17.95 ( = .002), potentially offsetting device costs within 13 weeks. The PaceyCuff shows potential as a low-cost conservative and well-tolerated option for male SUI, including in patients unsuitable for surgery. Larger scale studies are required to confirm the long-term efficacy and safety associated with PaceyCuff.
-
3. NOTES sacrocolpopexy versus sacrospinous ligament fixation for apical pelvic organ prolapse: a pilot, hypothesis-generating, single-centre retrospective comparative cohort study.
3. 骶骨阴道固定术与骶棘韧带固定术治疗顶端盆腔器官脱垂的比较:一项初步、假设生成性、单中心回顾性比较队列研究PMID:期刊:日期:2026-09-23To compare anatomical, functional, and safety outcomes of vaginal natural orifice transluminal endoscopic surgery (vNOTES) sacrocolpopexy (SCP) and vNOTES sacrospinous ligament fixation (SSLF) for apical pelvic organ prolapse (POP). Single-centre, single-surgeon, retrospective comparative cohort study conducted in accordance with the STROBE statement. Allocation to vNOTES SSLF ( = 24) or vNOTES SCP with a lightweight polypropylene Y-mesh ( = 32) was based on prespecified intra-operative feasibility criteria rather than randomisation. The primary outcome was composite apical anatomical success at 12 months (point C ≤ -5 cm and absence of apical POP-Q stage ≥ II). Secondary outcomes included perioperative parameters, visual analogue scale (VAS) pain scores, Quality-of-Recovery-40 (QoR-40), Prolapse Quality-of-Life (P-QOL), ICIQ-UI SF (International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form) and PGI-I scores, and complications classified with the Clavien-Dindo and IUGA/ICS Category-Time-Site systems. Baseline characteristics were balanced. Composite apical success at 12 months was achieved in 22/24 (91.7%) SSLF patients and 30/32 (93.8%) SCP patients (risk difference -2.1 percentage points; 95% CI, -17.6 to +13.5); this interval is compatible with clinically meaningful differences in either direction and does not support an inference of equivalence. Suspension time was shorter with SSLF (40.2 ± 11.8 vs 54.6 ± 12.7 min; < 0.001), as was total operative time (89.7 ± 15.2 vs 104.9 ± 17.6 min; = 0.001). Estimated blood loss, VAS pain, QoR-40, P-QOL, ICIQ-UI SF and PGI-I showed no statistically detectable difference. No intra-operative injuries, conversions to laparotomy, or mesh-related events (IUGA/ICS classification) were detected during a median follow-up of 21 months (range 6-36) for SSLF and 20 months (8-35) for SCP. In this hypothesis-generating single-surgeon cohort, vNOTES SSLF and vNOTES SCP showed no statistically detectable difference in short- to mid-term anatomical and patient-reported outcomes, with shorter suspension time favouring SSLF.
-
4. Ergonomic mismatch in circular staplers: powered staplers are associated with reduced sex-related disparities.
PMID:期刊:日期:2026-09-20Manual circular staplers have been recognized as difficult to operate, particularly for female surgeons. Recently, powered circular staplers have been developed to address these limitations. This study aimed to describe surgeons' satisfaction and perceived challenges with manual and powered staplers and evaluate sex-related differences in operability. A web-based survey was conducted among 18,261 members of the Japanese Society of Gastroenterological Surgery. The questionnaire collected demographic data, including sex, years since medical registration, and surgical glove size. It also assessed perceptions of manual and powered circular staplers, including stress or anxiety during use, situations associated with operational difficulty, overall satisfaction, and desired improvements. A total of 1,007 responses were obtained (859 men, 144 women, and four other/no response), yielding a response rate of 5.5%. Female surgeons had smaller glove sizes and fewer years of experience than male surgeons. With manual staplers, female surgeons reported higher levels of stress and anxiety during firing and lower overall satisfaction. The main issues identified were firing, handle size, and device weight. In contrast, powered staplers mitigated many of these challenges, improved satisfaction in both groups, and reduced sex-related differences in stressful situations during stapler operation. Powered circular staplers were associated with higher satisfaction than manual staplers among both male and female surgeons and may help reduce sex-related differences in operability. However, statistically significant sex-related differences persisted for some outcomes, and issues related to device weight remain, highlighting the need for further ergonomic improvements.
-
5. Telesurgery from Operation Lindbergh to global robotic hubs: history, evidence and future directions.
5. 从林德伯格行动到全球机器人枢纽的远程手术:历史、证据与未来方向PMID:期刊:日期:2026-09-17该文献暂无摘要。
-
6. Organ-sparing transanal endoscopic microsurgery for malignant rectal tumours: long-term survival and predictors of recurrence in a 333-patient cohort.
PMID:期刊:日期:2026-08-27Long-term outcomes and preoperative predictors after organ-sparing transanal endoscopic microsurgery (TEM) for rectal cancer remain incompletely defined. We assessed overall survival (OS), disease-free survival (DFS), and preoperative predictors. Consecutive patients undergoing TEM with organ-sparing intent for rectal adenocarcinoma between February 1993 and April 2025 were retrospectively analysed. Preoperative variables included age, sex, lesion diameter, distance from the anal verge, location, histology, and endoscopic ultrasound (EUS) uT stage. Survival was estimated by Kaplan-Meier analysis and Cox regression. 333 patients were included (median age 71 years; 63.1% male), with a median follow-up of 24 months. Post-TEM management comprised surveillance (28.5%), completion radical surgery (17.1%), or (chemo)radiotherapy (44.7%). Rectal preservation was achieved in 73.3%. 88 patients died and 71 developed recurrence, including 58 local and 26 distant recurrences. On multivariable analysis, age ≥71 years (adjusted HR 2.35, 95% CI 1.38-4.00; = 0.002) and EUS uT2-3 (adjusted HR 2.11, 95% CI 1.23-3.63; = 0.007) independently predicted worse OS. Organ-sparing TEM achieved rectal preservation in nearly three-quarters of patients, although recurrence was predominantly local. Age and EUS uT stage predicted OS, supporting staging and risk-adapted escalation.
-
7. {"_":"Robot-assisted partial nephrectomy in the era of novel robotic platforms: the first european experience with the toumai system.","sup":["®"]}
7. {"_":"新型机器人平台时代的机器人辅助肾部分切除术:Toumai系统的首个欧洲经验。","sup":["®"]}PMID:期刊:日期:2026-08-20To evaluate the feasibility and safety of robot-assisted partial nephrectomy (RAPN) performed using the Toumai robotic system in this first European experience. We conducted a prospective observational study including consecutive patients undergoing RAPN performed using the Toumai robotic system at a tertiary referral robotic centre between May and December 2025. Perioperative, postoperative, functional, and pathological data were collected. A total of 21 RAPN procedures were performed using the Toumai robotic system. Median patient age was 63 years, and 15 patients (71.4%) were male. Median tumour diameter was 3.2 cm. Median total operative time was 143 min, with a median console time of 90 min. No conversions to open surgery or radical nephrectomy occurred. Two robot-related technical events (9.5%) were recorded and managed intraoperatively without clinical consequences. One postoperative complication occurred (4.8%), graded as Clavien-Dindo I. No major complications, blood transfusions, or early readmissions (<30 days) were observed. Median length of hospital stay was three days. Median estimated glomerular filtration rate (eGFR) showed a minimal change at hospital discharge, with a median ΔeGFR of -2 mL/min/1.73m ( = 0.2). In this first European experience, RAPN performed using the Toumai robotic system was feasible and safe. Further studies are required to confirm long-term outcomes and comparative performance.
-
8. SEMS bridge to elective laparoscopic surgery versus emergency surgery for obstructive colorectal cancer: a propensity score-matched retrospective cohort study.
8. 自膨式金属支架桥接择期腹腔镜手术治疗梗阻性结直肠癌对比急诊手术:一项倾向性评分匹配的回顾性队列研究PMID:期刊:日期:2026-08-18This study compared perioperative recovery and clinical outcomes of patients with obstructive colorectal cancer (OCRC) undergoing self-expandable metallic stent (SEMS) placement followed by elective laparoscopic resection versus emergency surgery. Between January 2019 and January 2021, 83 patients were included: 51 underwent SEMS placement followed by elective laparoscopic resection and 32 underwent emergency surgery. Propensity score matching (PSM) yielded 56 patients (28 per group). Operative parameters, gastrointestinal recovery, postoperative complications, oncologic quality indicators, and overall survival (OS) were evaluated. Survival was analyzed using Cox proportional hazards regression. SEMS followed by elective laparoscopic resection was associated with shorter operative time and faster gastrointestinal recovery. Postoperative complications were numerically less frequent in the SEMS group (7.1% vs. 17.9%), although the difference was not significant (p=0.417). Adjusted Cox regression showed higher mortality risk after emergency surgery (HR=2.43, 95% CI 1.04-5.68, p=0.040), although only 16 deaths occurred. Two-year OS was numerically higher with SEMS (82.1% vs. 60.7%), without statistical significance (p=0.076). Conclusions: SEMS as a bridge to elective laparoscopic resection was associated with faster gastrointestinal recovery and fewer postoperative complications. The potential survival benefit warrants confirmation in larger prospective multicenter studies. SEMS placement as a bridge to elective laparoscopic resection was associated with improved gastrointestinal recovery and a numerically lower complication rate. The potential survival benefit requires confirmation in larger prospective multicenter studies.
-
9. Artificial intelligence in surgery: safety before automation.
9. 外科手术中的人工智能:安全先于自动化PMID:期刊:日期:2026-08-10该文献暂无摘要。
-
10. A proof-of-concept study of optical tissue sensing during vacuum-assisted breast biopsy procedures.
10. 真空辅助乳腺活检过程中光学组织传感的可行性研究PMID:期刊:日期:2026-08-06[中文摘要] 真空辅助乳腺活检(VABB)能够以微创方式对乳腺病灶进行取样,但无法提供所取组织的实时信息,可能导致取样偏差。我们评估了将漫反射光谱(DRS)整合到VABB工作流程中是否可行,以及能否支持更有针对性的取样。我们开发了一种配备光纤的导引器,与标准Hologic VABB系统兼容,可在不改变临床工作流程的情况下获取DRS测量数据。在40例离体乳房切除标本中,于超声引导下实施VABB,并在活检取样前即刻获取DRS测量数据。以组织病理学作为参考标准,使用标注光谱训练机器学习模型,分别采用按样本分类和按患者分类的方式区分健康组织与恶性组织。共300次活检与组织病理学结果进行了关联,形成包含248条光谱的平衡数据集。按样本分类模型的平均准确率为86%,灵敏度为91%,特异度为82%。按患者分类方法的相应指标分别为76%、85%和70%。这项概念验证研究表明,使用新型光学导引器可将DRS整合到VABB工作流程中,并能在离体乳腺标本中区分恶性组织与健康组织,支持了技术可行性。仍需进一步开展临床研究以确立其诊断价值。
[英文摘要] Vacuum-assisted breast biopsy (VABB) enables minimally invasive sampling of breast lesions but provides no real-time information about the tissue being sampled, potentially leading to sampling bias. We evaluated whether integrating diffuse reflectance spectroscopy (DRS) into the VABB workflow is feasible and can support more targeted sampling. A fiber-equipped introducer compatible with a standard Hologic VABB system was developed to acquire DRS measurements without altering the clinical workflow. In 40 ex vivo mastectomy specimens, ultrasound-guided VABB was performed, with DRS measurements obtained immediately before biopsy acquisition. Histopathology served as the reference standard, and labeled spectra were used to train machine learning models using sample-wise and patient-wise classification to distinguish healthy from malignant tissue. A total of 300 biopsies were correlated with histopathology, yielding a balanced dataset of 248 spectra. The sample-wise model achieved a mean accuracy of 86%, sensitivity of 91%, and specificity of 82%. The patient-wise approach achieved 76%, 85%, and 70%, respectively. This proof-of-concept study demonstrates that DRS can be integrated into the VABB workflow using a novel optical introducer and discriminate malignant from healthy tissue in ex vivo breast specimens, supporting technical feasibility. Further clinical studies are needed to establish its diagnostic value.