Medical Devices-Evidence and Research医疗器械:证据与研究
Medical Devices-Evidence and Research(英文缩写 MED DEVICES-EVID RES),ISSN 1179-1470,eISSN 1179-1470,中文译名:医疗器械:证据与研究 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 未收录 | N/A |
| 2022 | 1.300 | N/A |
| 2023 | 1.300 | Q4 |
| 2024 | 1.500 | Q4 |
| 2025 | 1.500 | Q4 |
Medical Devices-Evidence and Research 最新收录文献
-
1. A Novel Device for Pulmonary Expansion Under Simulated Healthy and Neuromuscular Conditions: A Bench Simulation Study.
PMID:日期:2026-09-30Amyotrophic Lateral Sclerosis (ALS) leads to a progressive decline in respiratory function, requiring volumetric expansion techniques to prevent hypoventilation. However, the mechanical performance of devices used for this purpose requires evaluation under controlled conditions in bench simulation studies. Devices, such as the manual resuscitator, are commonly used, but present limitations, including high pressures, variable flow, among others. A novel respiratory muscle training device designed to provide controlled flow and pressure (ILLIFE-T) was developed. To evaluate the behavior of the variables pressure, volume, and flow during the volumetric expansion technique, comparing the new device with the manual resuscitator and the manual resuscitator + Positive Expiratory Pressure (PEP), using simulated models of healthy and ALS affected lungs. This bench simulation study used the ASL 5000 simulator, configured with predefined respiratory profiles representing healthy and ALS respiratory conditions. Four repetitions of the volumetric expansion maneuver were performed for each device and simulated respiratory condition, with five insufflations per repetition. One recording was randomly selected from each repetition for analysis, resulting in four observations per device and simulated respiratory condition. In the simulation with healthy respiratory conditions, the new device generated higher pressure (23.38±3.81 cmHO), volume (1991.25 ±174.10 mL), and lower flow variability (-1.47±11.43 L/min) compared with the manual resuscitator (12.25±11.73 cmHO; 1113.64±131.75 mL; 18.84±61.31 L/min) and the manual resuscitator with PEP valve (16.89±0.64 cmHO; 1817.25±86.77 mL; -49.49±9.96 L/min), respectively. In ALS simulated models, the new device also achieved higher pressure (23.69±3.29 cmHO) and volume (2235.28±264.74 mL) compared with the manual resuscitator (8.33±8.34 cmHO; 563.45±212.03 mL, respectively) and the manual resuscitator with PEP valve (14.89±7.60 cmHO; 1449.86±153.09 mL, respectively). Flow values were similar among devices: 15.10 ± 18.00 L/min for the new device, 19.28±56.03 L/min for the manual resuscitator, and 0.18±51.67 L/min for the manual resuscitator with PEP valve. Pressure and volume were higher with the new device in both simulated models. Flow did not differ significantly among devices, although lower variability was descriptively observed with the new device.
-
2. Evolution of Radiofrequency Transseptal Puncture Devices.
PMID:日期:2026-09-22Transseptal puncture (TSP) is an indispensable step for establishing left atrial access and plays a pivotal role in complex left-heart interventions, including catheter ablation for atrial fibrillation, left atrial appendage occlusion, and transcatheter mitral valve therapy. As such, TSP ranks among the core techniques in contemporary cardiovascular interventional cardiology. Since its first description in the 1950s, TSP tools have undergone decades of iterative refinement, evolving from conventional mechanical needles to diverse energy-assisted puncture systems. The performance of a TSP system directly determines procedural success, safety, and patient prognosis. This article systematically reviews the developmental history of TSP devices, with a focused overview of the developmental background, technical evolution, clinical applications, and advantages of radiofrequency-based puncture devices (including radiofrequency guidewires and radiofrequency needles), and briefly outlines future directions for innovation.
-
3. A Silver-Zeolite Spray Powder for Pressure Ulcers and Minor Burns: Real-World Evidence from Primary Care.
3. 一种用于压力性溃疡和轻度烧伤的银沸石喷雾粉末:来自初级保健的真实世界证据PMID:日期:2026-09-14Pressure ulcers and minor burns are commonly managed in primary care. The tested device is an adsorbing spray powder combining ionic silver (2.5%) and micronized zeolite (97.5%), designed to provide exudate control and antimicrobial activity in a topical formulation. In this multicenter, open-label, single-arm post-market clinical follow-up (PMCF) study, adult outpatients with chronic stage II-III pressure ulcers (NPUAP) unhealed after ≥3 weeks of standard care, or with superficial/partial-thickness burns (<10% body surface area) within 48 hours of injury, received the tested product for 4 weeks. Co-primary endpoints were 4-week changes in PUSH (pressure ulcers) and Vancouver Scar Scale (VSS; burns) scores; secondary endpoints included pain (100-mm Visual Analog Scale), patient satisfaction, Investigator Global Assessment of Performance, and safety. Fifty-eight patients were enrolled and 56 analyzed per-protocol (32 burns, 24 pressure ulcers); two discontinued for reasons unrelated to safety. At Week 4, 96.4% (54/56) showed meaningful improvement and none worsened. Mean VSS decreased from 5.22±2.78 to 1.31±1.49 in burns (p<0.001; bias-corrected d_avg=1.72), and mean PUSH decreased from 11.67±2.41 to 3.29±1.60 in pressure ulcers (p<0.001; bias-corrected d_avg=4.01), with 95.8% of pressure-ulcer patients achieving a ≥5-point reduction. VAS pain decreased from Week 2 in both subgroups (p<0.001). At Week 4, the Investigator considered 68.8% of burns and 29.2% of pressure ulcers healed. Patient satisfaction was high (75.0% very satisfied, 25.0% satisfied); no adverse events, device effects or deficiencies were reported. In this single-arm, real-world study, the tested device showed a favorable performance and safety signal in mild-to-moderate pressure ulcers and minor burns; given the non-comparative design, these findings do not establish equivalence or superiority to other silver-based dressings. Ease of use may support outpatient self-managed care; adequately powered randomized trials versus alternative silver-based dressings are warranted to confirm these findings. ClinicalTrials.gov, NCT05649332.
-
4. Comparison of Gentleness and Reapplication Between Two Pulse Oximetry Probes in Healthy Adults in a Laboratory Setting.
PMID:日期:2026-09-14Many commonly used monitoring devices use adhesives to attach to the skin. These devices can cause avoidable skin damage, known as medical adhesive-related skin injury (MARSI). Pulse oximetry is a ubiquitous medical device used throughout care settings and, depending on the type of care, may have wear times over many hours or days. The purpose of these studies was to compare gentleness and reapplication of two pulse oximetry probes (Nellcor™ OxySoft™ neonatal-adult SpO sensor, Medtronic (silicone-based probe); LNCS Neo, Masimo (acrylic-based probe)). Institutional Review Board approval was obtained prior to study initiation and all participants provided informed consent prior to commencement of study procedures. Eighteen participants were enrolled in the gentleness trial and 19 participants were enrolled in the reapplication trial. For the gentleness trial, Trans-Epidermal Water Loss (TEWL) measurements were made at five sites on the forearm at three time points (baseline (T0), 4-hours post-initial wear (T1), 4-hours post-second wear (T2)). The total amount of protein adhered to each device was determined. For the reapplication trial, a series of 180° peel tests from the forearm were performed. For the gentleness trial, no significant differences in TEWL rates were noted between the two probes at any time point. When examining protein removal, the silicone-based probe removed approximately 75% less protein compared to the acrylic-based probe. For the reapplication trial, the silicone-based probe retained approximately 85% of initial peel-force retention after 18 reapplications, whereas after only two reapplications the acrylic-based probe retained approximately 50% of initial peel-force retention. In healthy adults in a laboratory setting both probes appeared to be gentle on skin. The silicone-based probe demonstrated the ability to withstand 18 reapplications without functional loss in adhesion.
-
5. A Prospective, Multi-Center, Randomized Controlled Study to Evaluate the Efficacy and Safety of Two Absorbable Barbed Sutures in Thyroid Surgery.
5. 一项前瞻性、多中心、随机对照研究,评估两种可吸收倒刺缝线在甲状腺手术中的疗效和安全性PMID:日期:2026-09-02This study aimed to evaluate the safety and effectiveness of two types of absorbable barbed sutures, STRATAFIX Spiral PDS Plus and STRATAFIX Spiral MONOCRYL Plus, compared with traditional sutures made of the same material in the suturing of thyroid surgery incision. This study was a multicenter, prospective, evaluator-blinded, three-arm, non-inferiority, randomized controlled design study with a planned enrollment of 501 patients undergoing open thyroid surgery. Subjects were randomized to Spiral PDS Plus group, Spiral MONOCRYL Plus group, or the control group, according to the allocation ratio of 1:1:1. The primary endpoint was the success rate of subjects achieving grade A healing of surgical incisions 5-7 days after surgery. A total of 500 subjects were randomized in this study. The PP analysis was considered the primary analysis, while the FAS analysis was considered supportive. In the PPset, which included 154 subjects in Spiral PDS Plus group, 157 subjects in Spiral MONOCRYL Plus group, and 156 subjects in the control group, the grade A wound healing success rates were 99.4%, 98.7%, and 99.4%, respectively. The differences [Wald 95% CI] in success percentage between the two investigation groups and the control group were -0.01% [-1.79%, 1.77%] and -0.63% [-2.79%, 1.52%], respectively. Both Spiral PDS Plus and Spiral MONOCRYL Plus were found to be non-inferior to control in achieving Grade A healing of surgical incision (0.05 margin, p < 0.0001 for both). This study demonstrated the short-term safety and efficacy outcomes of using STRATAFIX Spiral PDS Plus and STRATAFIX Spiral MONOCRYL Plus sutures in the suturing of thyroid surgery incision, with acceptable risk-benefit.
-
6. Research on Collaborative Management of Disinfection Supply Center and Operating Room Consumables Based on Information Ecology Theory.
PMID:日期:2026-08-29The coordination gap between the Central Sterile Supply Department (CSSD) and the Operating Room (OR) in surgical consumables management has become a bottleneck constraining surgical turnover and patient safety, yet existing digital implementations remain largely fragmented. This study aims to propose a conceptual framework for CSSD-OR consumable collaborative management based on information ecology theory, and to synthesize the integration pathways of key digital technologies. Using information ecology theory as the analytical framework (encompassing information, technology, human actors, and environment), this paper synthesizes the current literature on UDI, RFID, SPD models, data middleware, machine learning, and blockchain technologies in the CSSD-OR context. An integrated analytical framework is constructed by incorporating supply chain integration theory and socio-technical systems theory. Information chain ruptures were identified at three critical nodes: distribution-receiving, usage-billing, and recycling-reprocessing. A three-tier analytical framework is proposed, comprising a foundation layer (information chain integration), an intermediate layer (technology-process adaptation), and a guarantee layer (institutional-performance synergy). The "collection-transmission-processing-feedback" closed-loop mechanism is conceptualized as the core operational logic linking material flows, risk warning, and responsibility traceability. The digital transformation of CSSD-OR consumable management requires systematic restoration of information ecosystem imbalances rather than isolated technology deployment. The proposed framework offers a theoretical reference for hospitals seeking to move beyond technology stacking toward ecological collaboration, particularly within the Chinese healthcare context where UDI mandates and DRG/DIP reforms are ongoing.
-
7. Effects of Mechanical Nasal Stimulation on Olfaction.
7. 机械性鼻刺激对嗅觉的影响PMID:日期:2026-08-27Experimental studies have shown that the olfactory sensory receptor neurons not only identify odors and assess odor concentrations, but also act as respiratory mechanical sensors that respond to nasal airflow during breathing. Both odor detection and mechanical sensing appear mediated by a shared cellular mechanism. This prospective, single-arm, uncontrolled, pilot study was conducted to ascertain whether olfactory nerve mechanical stimulation provided by a nasal breathing oscillation device (Goodair Nosebuds) could influence olfaction when olfaction was assessed objectively. The study was performed on participants, who felt that their olfaction could be improved. Participants wore a nasal breathing oscillation device (Goodair Nosebuds) ten minutes twice a day for four weeks. At the beginning of the study and after four weeks, the participants' olfaction was assessed. Olfactory testing was performed using Sniffin' Sticks (phenyl ethyl alcohol threshold, odor discrimination and odor identification). After four weeks, participants using the nasal breathing oscillation device (Goodair Nosebuds), had an increase in olfactory function in phenyl ethyl alcohol threshold, and odor identification when compared to baseline. The global olfactory score (the sum of the three scores) increased. This prospective, single-arm, uncontrolled, pilot study indicates that olfactory nerve mechanical stimulation was associated with an improvement in olfactory scores. The study was registered with the Australian New Zealand Clinical Trials Registry (ANZCTR; ACTRN12625001131448).
-
8. A Physiology-Based Bridging Framework for Preliminary Cross-Population Evaluation of Plateletpheresis Devices: A Case Study of the NGL XF3000.
8. 基于生理学的桥接框架用于血小板单采设备跨人群初步评估:NGL XF3000的案例研究PMID:日期:2026-08-17Evaluation of new plateletpheresis devices across diverse donor populations traditionally relies on extensive multicenter clinical studies. This study proposes a physiology-based evaluation framework that integrates physiological modeling with external clinical observations to provide preliminary evidence for cross-population applicability. Physiological operating envelopes were derived from published anthropometric and hematological data together with established transfusion medicine principles. The framework was externally validated using published observations from the mature MCS+ plateletpheresis platform. The preliminary framework was subsequently applied to the NGL XF3000 by comparing its operating specifications and available clinical observations with the validated operating envelopes. The predicted operating envelopes accommodated physiological variation across major ethnic populations and were consistent with the operating characteristics of both the MCS+ platform and the NGL XF3000. Published MCS+ observations supported the physiological assumptions underlying the framework, while the available NGL XF3000 data were comparable with published reference observations regarding blood component changes and remained within the validated performance envelope. The proposed framework provides a physiology-based, resource-efficient approach for the preliminary evaluation of plateletpheresis devices before large-scale clinical validation. By integrating mechanistic modeling with external clinical evidence, it may facilitate the regulatory assessment of new devices intended for use across diverse donor populations.
-
9. Availability and Utilization of Radiological Guidance Tools in Interventional Radiology Units in Kinshasa, Democratic Republic of the Congo.
9. 刚果民主共和国金沙萨介入放射科单位中放射引导工具的可用性与使用情况PMID:日期:2026-08-11Various guidance techniques can be performed under ultrasound (US), computed tomography (CT), fluoroscopy, and magnetic resonance imaging (MRI) guidance; They pave the way for simple, intermediate, and complex minimally invasive procedures by improving visualization of the target, the access route, and device progression. This study aimed to evaluate the availability and utilization of radiological guidance tools in interventional radiology units in Kinshasa, Democratic Republic of the Congo. This descriptive study was conducted in selected medical facilities in Kinshasa. Data were collected from January 2018 to June 2024 using a structured questionnaire and medical record review. Eligible cases included patients who underwent semi-invasive diagnostic or therapeutic interventional radiology procedures performed under direct imaging guidance, with acceptable hemostatic parameters and documented informed consent. The evaluated outcomes included the type of radiological guidance used, anatomical or disease target, procedure complexity, and procedure-related incidents. Data were analyzed using descriptive statistics. Categorical variables were summarized as frequencies and percentages, and continuous variables were summarized as means and standard deviations when applicable. A total of 471 image-guided interventional radiology procedures were analyzed. The evaluated cases involved a range of anatomical and disease-related targets, including liver, breast, thyroid, prostate, spinal, cervical soft-tissue, splenic, pancreatic, renal, lymph-node, and other abdominal or soft-tissue lesions. Female patients represented 55.3% of the study population. Among the 471 interventional radiology procedures analyzed, age was available for 469 cases. The mean age was 48.2 ± 17.2 years, with a range of 1 to 84 years. Ultrasound was the most frequently used guidance modality, accounting for 384 procedures (81.5%), followed by CT guidance in 63 procedures (13.4%) and fluoroscopic guidance in 24 procedures (5.1%). Cone-beam CT guidance was not used. Simple interventional radiology procedures were the most common, accounting for 327 procedures (69.4%), followed by intermediate procedures in 126 cases (26.8%) and complex procedures in 18 cases (3.8%). This study shows that ultrasound guidance remains the most commonly used radiological guidance method in interventional radiology settings in Kinshasa. However, MRI, fluoroscopy-CT, electromagnetic, and cone-beam CT guidance were not used in this series. These findings provide baseline local evidence on current technical capacity and unmet equipment needs, and may help guide future planning and development of interventional radiology services in the Democratic Republic of the Congo.
-
10. Preclinical Performance Evaluation of an Oxidized Regenerated Cellulose Hemostat: Antibacterial Activity and Wound Healing Outcomes.
PMID:日期:2026-07-23Antimicrobial resistance (AMR) complicates surgical site infections (SSI), making it important to address surgical bleeding and bacterial bioburden. Oxidized regenerated cellulose (ORC) is a topical hemostat that generates a localized acidic microenvironment hostile to the survival of microbes. The present study evaluated the intrinsic antibacterial action and wound healing results of a commercial ORC-based hemostat in an infected wound environment. In vitro and in vivo experimental designs were used to evaluate the antibacterial activity. An in vitro experiment was designed to show inhibition zones against 32 Gram-positive and Gram-negative bacterial strains, including antibiotic-resistant pathogens, compared to the negative control. In vivo efficacy was tested in a Wistar rat excisional wound model (n = 42), in which polymicrobial inoculation was performed with the same bacterial strains, and animals allocated to specific groups were monitored for hemostasis time, wound contraction, clinical observations, and histopathology over 28 days. Using an agar diffusion method, ORC hemostat exhibited in vitro antibacterial activity against all the 32 tested strains. In vivo, hemostasis time was significantly reduced in the test groups compared to that in the disease control group (adjusted p < 0.001), achieving hemostasis within 42.2-54 seconds. Similarly, wound healing was statistically significant for the test specimens, achieving up to 88.5% wound closure by day 28 (adjusted p < 0.001). Histopathological analysis after 28 days revealed complete re-epithelialization of the wound bed and reduced inflammatory infiltration. Within the study limitations, the commercial ORC-based hemostat (Surgi-ORC) exhibited inherent antibacterial potential against various pathogens including antimicrobial-resistant organisms and provided rapid hemostatic action. These preclinical findings suggest that ORC may help reduce microbial burden, support wound healing along with tissue regeneration. Further clinical studies are warranted to establish the relevance of these observations in surgical practice.