Implant Dentistry种植牙科
Implant Dentistry,ISSN 1056-6163,eISSN 1056-6163,中文译名:种植牙科 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-10-01 至 2026-09-30,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2020 | 2.454 | Q3 |
| 2021 | 3.000 | Q2 |
Implant Dentistry 最新收录文献
-
1. Fifteen-Year Follow-up of Short Dental Implants in the Completely Edentulous Jaw: Submerged Versus Nonsubmerged Healing.
PMID:日期:2019-11-26Short implants are a minimally invasive alternative in the management of alveolar bone atrophy. This study aimed to assess the influence of the surgical approach (1-stage vs 2-stage) on the 15-year survival and marginal bone loss of short implants in a fixed complete denture. A retrospective clinical study was conducted in a single private dental clinic that included short implants placed between January 2001 and December 2002. Forty-one short implants supported 18 screw-retained complete dentures. The mean follow-up time was 15 ± 3 years. The surgical approach (1-stage vs 2-stage) did not significantly affect implant survival and marginal bone loss. The implant survival rate was 90.2%. Short dental implants could be predictably indicated to support fixed complete dentures. The implants could be placed through a 1- or 2-stage surgery.
-
2. Effect of 5 Popular Disinfection Methods on Microflora of Laboratory: Customized Implant Abutments.
PMID:日期:2019-10To compare the efficacy of 5 different decontamination methods of titanium abutments and to assess their possible effects on surface roughness of titanium. Micrococcus luteus, Acinetobacter baumannii, Enterococcus faecalis, and Candida albicans were cocultured to form a multispecies biofilm on 18 titanium discs. In another group, Bacillus subtilis, a spore-forming species, was cultivated on another set of 18 titanium discs. Each group was further divided into 5 test groups: high-pressure steam cleaning (4 Mpa, 5 seconds), NaOCl (1% active chlorine, 5 minutes), H2O2 (3%, 5 minutes), GaAlAs laser (810 nm, CW, 1 W, 400-μm fiber, 1-mm distance, 1 minute), Er:YAG laser (2940 nm, pulse mode, 100 mJ, 10 Hz, 230-μm noncontact handpiece, 4-mm distance, 50/50% air/water, 1 minute), and a control group of no treatment. After each decontamination procedure, the remaining microbial load was reported as colony-forming unit/disc. To evaluate the effect of each treatment on titanium discs, surface roughness parameters including Sa, Sq, Ssk, Sku, Sal, and Sdr were measured at 6 points of each disc using an atomic force microscope. Complete disinfection was achieved using high-pressure steam, NaOCl, H2O2, and Er:YAG laser. GaAlAs laser was able to reduce microbial count over 90%. Sa and Sq parameters were only increased significantly in diluted NaOCl group in comparison with control group, whereas Sdr was increased significantly in both absolute and diluted NaOCl groups. All the methods could decontaminate machined titanium surfaces, although complete microbial elimination was not achieved by diode laser. None of the treatments altered surface roughness significantly, except for sodium hypochlorite (NaOCl).
-
4. Indirect Sinus Augmentation With and Without the Addition of a Biomaterial: A Randomized Controlled Clinical Trial.
PMID:日期:2019-10-01The aim of this study was to compare the results of indirect sinus augmentation with and without the addition of a biomaterial. Thirty patients aged 40 to 60 years participated in this randomized controlled clinical trial. After closed sinus lift operation, patients were randomly and equally divided into blood clot control and acemannan sponge graft groups. Simultaneous implant placement was then performed. Cone beam computed tomography was performed immediately and at 3 and 6 months postoperation. Bone formation was evaluated by the radiographic endo-sinus bone gain percentage around the implant. Compared with the control group, the acemannan-treated group had a significantly greater radiographic endo-sinus bone gain percentage of approximately 2.4- and 2-fold at 3 and 6 months postsurgery, respectively (P < 0.05). The addition of a biomaterial (Acemannan) with indirect sinus augmentation and simultaneous implant placement significantly enhances bone formation at 3 and 6 months postsurgery.
-
6. Chemical Stability and Antimicrobial Activity of Plasma-Sprayed Cerium Oxide-Incorporated Calcium Silicate Coating in Dental Implants.
6. 等离子喷涂氧化铈掺入硅酸钙涂层在牙种植体中的化学稳定性和抗菌活性PMID:日期:2019-09-14The aim of this study is to investigate the biological activity and antibacterial property of cerium oxide-incorporated calcium silicate coatings (CeO2-CS) in dental implants. In this study, MC3T3-E1 cells cultured on the plastic, Ti-6Al-4V, and the cerium oxide-incorporated calcium silicate coatings (CeO2-CS) coating served as the blank, control, and CeO2-CS groups, respectively. A cell counting kit-8 (CCK-8) and flow cytometry were used to evaluate the biocompatibility. The osteoblastic differentiation of the MC3T3-E1 cells was also analyzed by quantitative real-time polymerase chain reaction analysis. The CCK-8 and counts of colony-forming units (CFUs) were used to detect the antibacterial activity of the coating on Enterococcus faecalis. The study showed that the cerium oxide-incorporated calcium silicate coating (CeO2-CS) has better biocompatibility. Meanwhile, the ALP, OCN, and BSP mRNA expression levels in the CeO2-CS group were significantly upregulated (P < 0.05). The number of viable bacteria and the CFU results were significantly reduced in the CeO2-CS group (P < 0.05). The cerium oxide-incorporated calcium silicate coatings (CeO2-CS) may promote the osteoblastic differentiation of osteoblasts. Meanwhile, the cerium oxide-incorporated calcium silicate coating (CeO2-CS) showed strong antimicrobial activity on E. faecalis, with good biocompatibility.
-
7. Accuracy of Computer-Guided Template-Based Implant Surgery: A Computed Tomography-Based Clinical Follow-Up Study.
PMID:日期:2019-09-14The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a-d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69-1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99-1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04-5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42-0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.
-
8. Sinus Floor Elevation and Antrostomy Healing: A Histomorphometric Clinical Study in Humans.
8. 窦底抬高和米索前列醇治疗:人类组织形态计量学临床研究PMID:日期:2019-08-20To compare the histomorphometric outcomes of biopsies collected from the antrostomy and from the alveolar crest of the maxillary sinus after a sinus-lift procedure. In 12 volunteers, sinus floor elevation was performed using collagenated corticocancellous porcine bone. Nine months after the surgery, 2 biopsies, 1 from the alveolar crest and 1 from the antrostomy, were collected for histological analysis. Biopsies from 11 patients were available for histological analyses (n = 11). At the alveolar crest sites, the percentage of mineralized bone was 40.1 ± 14.1%, of bone marrow was 40.1 ± 18.0%, and of the xenograft was 14.7 ± 15.2%. Small amounts of soft tissue were found. At the antrostomy sites, the percentages of mineralized bone, bone marrow, and xenograft were 26.0 ± 10.8%, 23.4 ± 17.0%, and 28.2 ± 15.7%, respectively. Soft tissue was represented by 19.7 ± 19.4%. Higher amounts of mineralized bone and bone marrow were found in the alveolar crest compared with the antrostomy.
-
9. Evaluation of Risk Parameters in Bone Regeneration Using a Customized Titanium Mesh: Results of a Clinical Study.
PMID:日期:2019-08-03The aim of the study was an evaluation of risk factors for an innovative bone regeneration technique using a customized titanium mesh that was tested in a clinical setting. This retrospective study included 65 patients with 70 grafting procedures of osseous defects of the jaws with a customized titanium mesh together with Advanced- and Injectable-Platelet-Rich Fibrin (A- and I-PRF), resorbable membranes, and bone grafting materials. Exposures of the meshes and grafting outcome were analyzed according to a novel classification as (a) punctual and (b) tooth width or complete exposure of the mesh (c). No exposure was stated as (d). In 37% of cases, exposures of the meshes occurred that were significantly associated with loss of grafted material (P < 0.001). Tobacco abuse (P = 0.032) and grafting procedures together with simultaneous sinus floor elevation techniques (P = 0.001) were found to be risk factors for success of the grafted material. Implant placement was not possible in 2 cases only. The results of this study verified the treatment of large defects with a customized titanium mesh as a useful protocol with a predictable outcome, even in cases of dehiscences.
-
10. The Effect of One-Abutment at One-Time on Marginal Bone Loss Around Implants Placed in Healed Bone: A Systematic Review of Human Studies.
PMID:日期:2019-08-03The primary aim of the present article was to review the effect and the clinical significance of abutment dis- and reconnection on the peri-implant marginal bone levels. English articles published from 2009 to April 2019 were identified on the MEDLINE, Cochrane Library, and PubMed databases, according to the PRISMA guidelines. Comparative in vivo studies on humans were included. A total of 4 studies with different levels of bias were included in this review. A significant heterogeneity of the reported data was observed, which limited the comparison of the findings. The only parameter that was homogenous throughout all 4 studies was the marginal bone level measurement. Within the limitations of the present review, it can be suggested that minimizing the number of abutment dis- and reconnections would be beneficial to ensure minimal disruption to the peri-implant tissue and marginal bone level. However, the clinical significance of the marginal bone level changes is still inconclusive.