COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING生物力学与生物医学工程中的计算方法
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING(英文缩写 COMPUT METHOD BIOMEC),ISSN 1025-5842,eISSN 1476-8259,中文译名:生物力学与生物医学工程中的计算方法 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.669 | Q4 |
| 2022 | 1.600 | Q4 |
| 2023 | 1.700 | Q3 |
| 2024 | 1.600 | Q4 |
| 2025 | 1.900 | Q3 |
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING 最新收录文献
-
1. A dual-stream multi-scale cross-attention network for pericardial effusion detection.
PMID:日期:2026-10-04Early detection of pericardial effusion (PE) is clinically important because delayed diagnosis may cause severe cardiac complications. We propose a Dual-Stream Multi-Scale Cross-Attention Network (DS-MSCA) for automatic PE detection using simultaneously acquired electrocardiogram (ECG) and phonocardiogram (PCG) signals. Multi-scale Inception-ResNet encoders capture waveform and rhythm variations, while bidirectional cross-attention models cardiac electromechanical coupling. On a clinical dataset of 149 patients, DS-MSCA achieved 93.26% accuracy, 95.28% sensitivity, and a 95.01% F1-score. Attention maps and Grad-CAM++ showed that the model focused on clinically relevant heart-sound abnormalities while integrating complementary ECG information, supporting non-invasive PE screening.
-
2. Towards minimally invasive prosthetic surgery of the temporomandibular joint: design and integrated CAD-FEM preclinical approach on the mini-pig.
PMID:日期:2026-09-25A patient-specific, minimally invasive temporomandibular joint prosthesis was developed using an integrated workflow combining medical imaging, semi-automated CAD modeling, finite element analysis, and additive manufacturing. A minipig anatomical model was used to assess geometric feasibility and preliminary structural behavior. Three condylar component sizes were evaluated under simplified loading conditions, with additional simulations examining loading orientation. Miniaturization maintained stresses below the assumed material yield strengths, while peak stresses remained localized near the inferior bone-contacting edge. Physical fitting confirmed geometric conformity and surgical feasibility. This proof-of-concept study demonstrates the feasibility of an anatomy-specific workflow for designing and manufacturing miniaturized TMJ prostheses.
-
3. An inverse approach to estimating cervical spine disc material properties and disc stress under In vivo load.
PMID:日期:2026-09-24This study presents a novel inverse finite element approach to estimate cervical spine biomechanical function. A physics-constrained optimization framework is used to estimate subject-specific intervertebral disc properties and applied loads that reproduce measured motion. As a proof-of-concept, analysis of a healthy human subject was able to accurately replicate vertebral kinematics within 1 mm on average. Incorporating material heterogeneity significantly improved predictions, while loading assumptions influenced estimated stress distributions. Despite some nonuniqueness in parameter estimation, disc stress patterns remained consistent. As a proof-of-concept with one healthy subject and one flexion motion, this approach shows early promise for noninvasively assessing tissue properties.
-
4. Knee joint biomechanics during lunges at different tibial angles and external loads: a musculoskeletal analysis with finite element insights.
PMID:日期:2026-09-23This study investigates knee joint biomechanics during lunges under varying tibial angles and external loads using musculoskeletal modeling and finite element analysis. Twenty-six healthy young men performed lunges at tibial inclination angles relative to the ground (60° and 90°) under two external load conditions. Knee joint moment was higher at 60° than at 90°. External load affected knee stiffness, with lower rotational stiffness under the 98 N external-load condition. Under the 90° tibial-angle condition with external load, peak stress and displacement were concentrated in the posterior horn of the meniscus. These findings provide biomechanical support for lunge-based training and rehabilitation.
-
5. RTSANet: learning sequential-attentive hybrid networks for drug information-enhanced medication recommendation.
PMID:日期:2026-09-23Medication recommendation supports safe and personalized treatment based on patients' electronic health records(EHR). However, modeling complex dependencies in longitudinal records while ensuring medication safety remains challenging. We propose RTSANet, which integrates inter-visit drug similarity and external adverse drug reaction information. It captures medication relationships across visits, enhances drug representations with safety-related knowledge, and generates more accurate and safer medication combinations. Validation on the MIMIC-III and MIMIC-IV datasets demonstrates that RTSANet achieves 0.5360 Jaccard, 0.6895 F1 and 0.7869 PRAUC, improving recommendation accuracy and medication safety.
-
6. Modeling rod elasto-plasticity improves biomechanical simulation of adolescent idiopathic scoliosis instrumentation.
6. 棒材弹塑性建模改善青少年特发性脊柱侧凸内固定术的生物力学仿真PMID:日期:2026-09-23In adolescent idiopathic scoliosis instrumentation surgery, spinal rods undergo substantial elasto-plastic deformation resulting in flattening, yet most biomechanical models represent rods as linear-elastic. We evaluated two approaches to account for elasto-plasticity and their improvement over conventional linear-elastic modeling in 14 patient-specific physics-based simulations with identical instrumentation constructs: a computationally efficient approximation of permanent contour loss and a material-based approach using nonlinear stress-strain behavior to estimate plastic deformation. Linear-elastic modeling overestimated postoperative rod curvature, sagittal correction and forces, whereas both elasto-plastic approaches better reproduced postoperative rod shape and global alignment. Incorporating rod elasto-plasticity improves the biomechanical fidelity of surgical simulation.
-
7. Deep learning-based classification of cortical and subcortical ischemic stroke infarction using fNIRS signals.
PMID:日期:2026-09-23Distinguishing cortical from subcortical ischemic stroke may help guide management. We developed DBT-Net, which combines a DHR residual module, BiLSTM, and Transformer, to classify stroke subtypes from fNIRS signals. The model was evaluated by patient-wise stratified five-fold cross-validation in 175 participants under verbal fluency, right-hand grasp, and resting-state conditions. Accuracy was 0.886 ± 0.055, 0.913 ± 0.062, and 0.878 ± 0.046, with AUCs of 0.920 ± 0.072, 0.912 ± 0.069, and 0.900 ± 0.034, respectively. SHAP analysis highlighted cortical channels contributing most to the predictions.
-
8. Identification of anoikis-related and cell matrix adhesion genes in the progression of colon adenocarcinoma using bioinformatics analysis.
PMID:日期:2026-09-23To develop an innovative prognostic model for colon adenocarcinoma (COAD), we integated anoikis- and cell matrix adhesion (CMA related mechanisms using TCGA and GEO datasets. Six genes (BST2, NAT1, OFCC1, HOTAIR, TRIP6, ADAMTS13) were identified, risk model stratified patients into high- and low risk groups with distinct survival (p=0.025), validated in GSE17536. A nomogram showed good predictive accuracy. Functional enrichment highlighted tumor-, anoikis-, and CMA-related pathways, immune infiltration correlated with prognostic signature and risk score. High-risk patients were more sensitive to afatinib, osimertinib, and navitoclax; low-risk patients to paclitaxel, docetaxel, and gemcitabine. These genes may serve as prognostic biomarkers and guide tailored COAD therapy.
-
9. Operator learning for hemodynamics on variable domains: 2D stenosis and bifurcation.
PMID:日期:2026-09-22We study neural-operator surrogates for steady incompressible Navier-Stokes flow on variable two-dimensional coronary-like domains. Two finite-element datasets are constructed: stenosed channels and bifurcating vessels, each with 1000 geometries. We compare a reference-domain MIONet based on diffeomorphic registration with geometry-aware point-cloud operators, GNOT and PCNO. PCNO gives the strongest in-distribution accuracy and best extrapolation to unseen inflow velocities, whereas MIONet is most stable under the tested OOD shape shift and fastest per forward pass. Currents-based geometric dissimilarity helps characterize error trends and supports reliability-aware surrogate assessment.
-
10. Comparative evaluation of spline-based and Laplace-based interpolation for joint torque field reconstruction: a simulation study.
PMID:日期:2026-09-16Accurate interpolation of joint torque fields across joint angle combinations is essential in experimental and clinical biomechanics. Although thin-plate spline (TPS) interpolation is widely used, its exact interpolation property renders it sensitive to outliers. The present study compared TPS, thin-plate smoothing spline (TPSS) with two smoothing levels, and discrete Laplace interpolation under controlled simulation conditions. Two ground truth surfaces were defined: a physiologically motivated single-peak surface representing plantarflexion torque as a function of ankle and knee angles and a two-peak surface representing a more complex spatial structure. Noisy measurement conditions were simulated by sampling each surface on a jittered 5 × 5 grid, adding proportional Gaussian noise (5% or 10%), and introducing outliers (0-5 points, ±10% or ±20%) or missing data (0-5 points). Each condition was simulated 1000 times, and reconstruction accuracy was quantified by root mean square error (RMSE) and absolute deviation from the median, with method comparisons performed using Wilcoxon signed-rank tests. For the single-peak surface, TPSS with greater smoothing consistently yielded the lowest RMSE across outlier conditions, whereas TPS was most adversely affected by outliers. For the two-peak surface, TPS outperformed other methods, and Laplace interpolation consistently produced the largest RMSE. Under missing-data conditions, spline-based methods showed comparable or superior accuracy to Laplace interpolation, despite its theoretical suitability for handling missing data. These findings empirically demonstrate condition-dependent differences in interpolation accuracy across methods and suggest that method selection should be guided by prior knowledge or preliminary assessment of the spatial complexity of the target torque field.