SURFACE & COATINGS TECHNOLOGY表面与涂层技术
SURFACE & COATINGS TECHNOLOGY(英文缩写 SURF COAT TECH),ISSN 0257-8972,eISSN 1879-3347,中文译名:表面与涂层技术 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.865 | Q1 |
| 2022 | 5.400 | Q1 |
| 2023 | 5.300 | Q1 |
| 2024 | 6.100 | Q1 |
| 2025 | 6.900 | Q1 |
SURFACE & COATINGS TECHNOLOGY 最新收录文献
-
1. Plasma sprayed fluoride and zinc doped hydroxyapatite coated titanium for load-bearing implants.
PMID:日期:2022-04-22Titanium (Ti) alloys show excellent fatigue and corrosion resistance, high strength to weight ratio, and no toxicity; however, poor osseointegration ability of Ti may lead to implant loosening . Plasma spraying of hydroxyapatite [HA, Ca (PO) (OH)] coating on Ti surfaces is commercially used to enhance osseointegration and the long-term stability of these implants. The biological properties of HA can be improved with the addition of both cationic and anionic dopants, such as zinc ions (Zn) and fluoride (F). However, the hygroscopic nature of fluoride restricts its utilization in the radiofrequency (RF) plasma spray process. In addition, the amount of doping needs to be optimized to ensure cytocompatibility. We have fabricated zinc and fluoride doped HA-coated Ti6Al4V (Ti64) to mitigate these challenges using compositional and parametric optimizations. The RF induction plasma spraying method is utilized to prepare the coatings. Multiple parametric optimizations with amplitude and frequency during the processing result in coating thicknesses between 80 and 145 μm. No adverse effects on the adhesion properties of the coating are noticed because of doping. The antibacterial efficacy of each composition is tested against for 24, 48, and 72 h, and showed that the addition of zinc oxide and calcium fluoride to HA leads to nearly 70 % higher antibacterial efficacy than pure HA-coated samples. The addition of osteogenic Znand F leads to 1.5 times higher osteoblast viability for the doped samples than pure HA-coated samples after 7-days of cell culture. Zn and F doped HA-coated Ti64 with simultaneous improvements in anti-bacterial efficacy and biocompatibility can find application in load-bearing implants, particularly in revision surgeries and immune-compromised patients.
-
2. {"_":"Wettability and study of titanium surface profiling prepared by electrolytic plasma processing.","i":["in-vitro"]}
2. {"_":"电解等离子体加工制备的钛表面轮廓的润湿性及研究。","i":["体外"]}PMID:日期:2021-03-31Electrolytic plasma processing (EPP) was used to create hydrophilic surface profiles on titanium. The wettability, surface morphology characteristics and chemical composition of the treated samples were studied as a function of EPP processing parameters. The EPP profiled surfaces comprised of a characteristic "hills and valleys" morphology because of continuous surface melting and freezing cycles. A bimodal surface profile was produced with 2-3 μm height hills and valleys with nano-roughness (≤200 nm). The produced profile resulted in a significant contact angle decrease (from 38.7° to 5.4°). Ratios of actual surface area to projection area () and fraction of solid surface remaining dry () were obtained from profilometry. The surface characteristics and large values produced by EPP were able to induce . Hence, EPP produced superhydrophilic surfaces on Ti. The bioactivity of EPP treated Ti was evaluated using cell free and MC3T3 cells studies. The treated Ti surface significantly increased the bioactivity and formed stoichiometric hydroxyapatite after immersion in a bone cell culture medium for 21 days. Cells' attachment and proliferation studies indicated that EPP treated surface significantly enhances the cells' adhesion and growth after 24 and 48 h compared to the untreated surface. The results show that Ti surface profiling by EPP constitutes a promising method to potentially improve bone implant bonding.
-
3. Nanostructured composite coating endowed with antiviral activity against human respiratory viruses deposited on fibre-based air filters.
PMID:日期:2021-01-17The widespread of viral airborne diseases is becoming a critical problem for human health and safety, not only for the common cold and flu, but also considering more serious infection as the current pandemic COVID-19. Even if the current heating, ventilating and air conditioning (HVAC) systems limit the disease transmission by air, the air filters are susceptible to microbial colonization. In addition, viruses spread via droplets (aerosol) produced by direct or indirect contact with infected people. In this context, the necessity of an efficient HVAC system, able to capture and inactivate viruses- and bacteria-rich aerosols, thus preserving a safe indoor air environment and protecting people, is of enormous importance. The aim of this work is the assessment of the antiviral properties of a silver nanoclusters/silica composite coating deposited via co-sputtering technique on glass, on metallic fibre-based air filters as well as on cotton textiles. The selected human respiratory viruses are: (RSV), the human (HRV) and the virus type A (FluVA). The coated air filters show that the nanostructured coating develops a strong virucidal activity against RSV and FluVA, but not against the HRV.
-
4. Multi-layer structure of Inconel 625 coatings prepared by magnetron sputtering.
4. 磁控溅射制备的Inconel 625涂层的多层结构PMID:日期:2021-01The coating/substrate interface and oxide layers of the Inconel 625 film may have significant impacts on its material properties, especially the corrosion behavior of the film. However, since the interface and oxide layer can be very thin and experimental toolbox to characterize them is limited, the detailed vertical structure of Inconel 625 coatings remains poorly understood. In this study, a multi-layer structure in Inconel 625 film prepared by magnetron sputtering is revealed using X-ray reflectometry (XRR) and neutron reflectometry (NR) techniques. Thickness and major composition of each layer are obtained. The results indicate that there exists a ~2 nm-thick Cr-rich Inconel sublayer underneath the main Inconel 625 film. An oxide layer mainly consisting of NiO with thickness of ~2 nm is found on the surface of the main Inconel 625 film. In addition, we identified a ~2 Å contamination layer between sapphire substrate and Inconel film even after argon ion sputtering cleaning. We also found that the thickness of the main Inconel 625 film grows linearly with the deposition time, with thicknesses of other layers remaining constant. Our findings provide insight into the multi-layered structures of Inconel 625 coatings with atomic-scale spatial resolution and give directions for future study to improve the corrosion resistance of Inconel 625 coatings.
-
5. Antibiofilm coatings through atmospheric pressure plasma for 3D printed surgical instruments.
5. 通过常压等离子体在3D打印手术器械上制备抗生物膜涂层PMID:日期:2020-07-05Recently, medical applications for 3D printing are expanding rapidly and are expected to revolutionize health care, specifically, manufacturing surgical guides and protective face mask against coronavirus (COVID-19). These instruments come in contact with the human tissues, being necessary 3D printed materials free of pathogenic microbes or other contaminants. Therefore, they must be sterilized to avoid that bacteria can attach to the surface and produce biofilm. With the aim of avoiding bacterial biofilm formation and minimize the health risks, acrylic acid (AcAc) coatings applied by plasma-polymerization have been deposited on 3D printed polylactic acid (PLA) Petri dishes. Six antimicrobial-resistant clinical and two susceptible control strains of and species were analyzed. AcAc coatings provide the surface with greater hydrophilicity and, consequently, the formation of a hydration layer, whose thickness is related to the surface roughness. This hydration layer could explain the reduction of bacterial attachment and, consequently, the biofilm formation. Antibiofilm coatings are more successful against strains than against ones; due to some coatings presents a smaller topography scale than the length, reducting the contact area between the bacteria and the coating, and causing a potential rupture of the cellular membrane. AcAc coatings with less number of plasma passes were more effective, and showed up to a 50% relative biofilm reduction (in six of the eight strains studied) compared with the untreated plates.
-
6. Effects of vitamin C on osteoblast proliferation and osteosarcoma inhibition using plasma coated hydroxyapatite on titanium implants.
6. 维生素C对钛植入物上等离子喷涂羟基磷灰石作用下成骨细胞增殖及骨肉瘤抑制的影响PMID:日期:2020-04-15Plasma-sprayed hydroxyapatite (HAp) coated titanium (Ti) implants are being extensively used in orthopedic surgeries and post-tumor resection to repair load-bearing segmental bone defects. In this study, vitamin C, an abundantly available natural biomolecule, is loaded onto plasma-sprayed HAp-coated commercially pure titanium (cpTi) surface to evaluate its chemopreventive and osteogenic properties, suggesting its clinical significance as an alternative or adjunct therapy in the treatment for osteosarcoma bone resection. Controlled release of vitamin C from HAp coated cpTi implant is assessed by drug release study, where Korsmeyer-Peppas model was applied to understand the release kinetics. After 21 days, the implants loaded with 400 and 800 μg of vitamin C showed a cumulative release of 62.7 and 74.1% in acidic microenvironment, whereas, 50.9% and 53.1% of total vitamin C release were observed by the implants loaded with 400 and 800 μg of vitamin C in physiological pH, respectively. To observe the effects of vitamin C release on osteosarcoma and osteoblast cellular activity, MG-63 (human osteosarcoma) and hFOB (human fetal osteoblast) cells were cultured on the surface of the implant and MTT cell viability assay and FESEM were carried out at 3 and 7 days of culture. Presence of high dosages 25 mM vitamin C shows a statistically significant (p≤0.05) decrease in osteosarcoma cell viability after 3 days, while both 5 mM and 25mM vitamin C reduced cellular viability by 2.5 folds (p≤0.05) compared to the control after 7 days. Interestingly, the presence of vitamin C showed no obvious signs of cytotoxicity towards osteoblast cell-line at day 3 and day 7, as confirmed by the MTT assay. Additionally, the FESEM images depict layers of hFOB cellular morphology on the surface of the implants, suggesting excellent cytocompatibility towards the osteoblast cells. These results suggest that vitamin C loaded HAp coated cpTi implant with improved osteogenic and chemopreventive properties can be considered as a promising reconstructive option to repair the post-tumor resection defects in osteosarcoma.
-
7. Effects of Al-Si Coating and Zn Coating on the Hydrogen Uptake and Embrittlement of Ultra-High Strength Press-Hardened Steel.
7. 铝硅涂层与锌涂层对超高强度压硬化钢氢吸收与氢脆的影响PMID:日期:2019Press-hardened steel (PHS), used for automotive safety-related structure parts, is sensitive to hydrogen embrittlement due to its martensitic microstructure. Hydrogen is introduced in PHS during the hot press forming (HPF) process, by an atmospheric corrosion process. In this study, the hydrogen embrittlement behavior of uncoated, aluminized, and galvanized PHSs was investigated. The Al-10%Si coating promoted the absorption of diffusible hydrogen at elevated temperature during the HPF while the reacted coating layer prevented the absorbed hydrogen from out-diffusing through the reacted coating surface layer at room temperature. Therefore, the aluminized PHS showed a greater sensitivity to both the hydrogen uptake and the resultant embrittlement, as compared to the uncoated and galvanized PHSs. Use of galvanized PHS for HPF application reduces the risk of hydrogen embrittlement, since the Zn coating effectively prevents the hydrogen uptake. The greater embrittlement resistance of the galvanized PHS is possibly due to the inhibition of the hydrogen generation reaction by the surface ZnO oxide layer and the low rate of hydrogen transport through the liquid Zn phase.
-
8. Diamond coated artificial cardiovascular devices.
8. 金刚石涂层人造心血管装置PMID:日期:2016-06-16Ultrananocrystalline diamond (UNCD), an extremely smooth, low cost diamond coating was successfully developed herein for antithrombogenic application which requires high biocompatibility, low wear, low friction, and chemical inertness. The substrate materials utilized in the Jarvik 2000 ventricular assist device (VAD), silicon carbide and titanium alloy, provide an excellent substrate match for UNCD integration. The paper addresses the development of medical-quality UNCD films to significantly improve the knowledge base regarding the defect mechanisms of UNCD films, to reduce or eliminate known wear-inducing imperfections in the film, and to thoroughly characterize and test the films as well as assembled UNCD-coated VADs. After the defect reduction and seeding experiments to improve film adhesion and coating quality, the best candidate deposition method has been down-selected for coating and assembly of VAD parts from Jarvik Heart. The coated and assembled devices have been tested with mechanical and blood-simulating fluid hydrodynamic testing at Jarvik Heart for full verification of the new coating technology. UNCD interface takes advantage of combining unmatched durability and antithrombogenicity.
-
9. Deposition, Heat Treatment And Characterization of Two Layer Bioactive Coatings on Cylindrical PEEK.
9. 圆柱形聚醚醚酮上双层生物活性涂层的沉积、热处理与表征PMID:日期:2015-12-17Polyether ether ketone (PEEK) rods were coated via ion beam asssited deposition (IBAD) at room temperature. The coating consists of a two-layer design of yttria-stabilized zirconia (YSZ) as a heat-protection layer, and hydroxyapatite (HA) as a top layer to increase bioactivity. A rotating substrate holder was designed to deposit an even coating on the cylindrical surface of PEEK rods; the uniformity is verified by cross-sectional measurements using scanning electron microscopy (SEM). Deposition is followed by heat treatment of the coating using microwave annealing and autoclaving. Transmission electron microscopy (TEM) showed a dense, uniform columnar grain structure in the YSZ layer that is well bonded to the PEEK substrate, while the calcium phosphate layer was amorphous and pore-free in its as-deposited state. Subsequent heat treatment via microwave energy introduced HA crystallization in the calcium phosphate layer and additional autoclaving further expanded the crystallization of the HA layer. Chemical composition evaluation of the coating indicated the Ca/P ratios of the HA layer to be near that of stoichiometric HA, with minor variations through the HA layer thickness. The adhesion strength of as-deposited HA/YSZ coatings on smooth, polished PEEK surfaces was mostly unaffected by microwave heat treatment, but decreased with additional autoclave treatment. Increasing surface roughness showed improvement of bond strength.
-
10. {"_":"Vacancy-dependent stability of cubic and wurtzite Ti Al N.","sub":[{"_":"1-","i":["x"]}],"i":[{"sub":["x"]}]}
PMID:日期:2015-08-15While it is well-known that supersaturated cubic-structured Ti Al N can be prepared by physical vapor deposition, the impact of point defects on formation process and cubic to wurtzite transition is largely unexplored. Irrespective of point defects, ab initio calculations correctly predict the Al concentration of the cubic to wurtzite transition. By means of density functional theory we show that vacancies on metal and/or non-metal sites only slightly affect the cubic to wurtzite transition region, whereas they clearly affect the physical properties.