JOURNAL OF CLINICAL ULTRASOUND临床超声杂志
JOURNAL OF CLINICAL ULTRASOUND(英文缩写 J CLIN ULTRASOUND),ISSN 0091-2751,eISSN 1097-0096,中文译名:临床超声杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 0.869 | Q4 |
| 2022 | 0.900 | Q4 |
| 2023 | 1.200 | Q3 |
| 2024 | 1.400 | Q3 |
| 2025 | 1.300 | Q3 |
JOURNAL OF CLINICAL ULTRASOUND 最新收录文献
-
1. Primary Hepatic Gastrointestinal Stromal Tumor: A Case Report.
PMID:日期:2026-10-02A primary hepatic gastrointestinal stromal tumor presenting with fever, initially misdiagnosed as liver abscess and drained was ultimately confirmed by pathology.
-
2. The Role of Umbilicocerebral Ratio and Cerebroplacental Ratio in Predicting Adverse Perinatal Outcomes in Women Undergoing Labor Induction.
PMID:日期:2026-10-02To evaluate the predictive value and clinical significance of pre-induction Doppler blood flow parameters of the umbilical artery (UA) and middle cerebral artery (MCA), as well as cerebroplacental ratio (CPR), and umbilicocerebral ratio (UCR) for fetal distress during labor induction. This prospective study evaluated women at term undergoing labor induction using pre-induction Doppler ultrasonography. Following the fetal distress diagnostic criteria, they were divided into two groups as the fetal distress group (n = 225) and the control group (n = 304) who underwent vaginal delivery. Parameters between the groups were compared; binary logistic regression was applied, and receiver operator characteristic (ROC) curve analysis was performed on the middle cerebral artery flow value. In the fetal distress group, the PI values and Z-score of the umbilical artery and umbilicocerebral ratio exceeded those in the control group, and the PI values and Z-score of the middle cerebral artery and cerebroplacental ratio were lower than those in the control group. An MCA PI cutoff value of 1.44 demonstrated 88.9% sensitivity and 80% specificity for predicting fetal distress. Umbilical artery and middle cerebral artery PI values may serve as useful parameters in the assessment of fetal distress.
-
3. Diagnostic Pitfalls of High-Frequency Ultrasound in Pediatric Peripheral Neurogenic Tumors: An Analysis of 44 Challenging Cases.
PMID:日期:2026-09-30This study systematically analyzed misdiagnosis classification, incidence and root causes of pediatric peripheral neurogenic tumors on high-frequency ultrasound among diagnostically ambiguous cases, and summarized core diagnostic pitfalls. We retrospectively collected clinical and ultrasonographic data from 44 children with superficial soft tissue masses treated between January 2022 and June 2026. Final diagnoses were confirmed via surgical pathology, pathogenic genetic testing combined with typical multimodal imaging, or multidisciplinary consensus after a minimum 12-month clinical and MRI follow-up. Only atypical lesions with initial ultrasound suspicion of neurogenic origin were enrolled; all cases with classic definitive sonographic signs were excluded. Using final pathological or follow-up diagnosis as the gold standard, we quantified misdiagnosis proportions and categorized misdiagnosis patterns. Of the 44 enrolled children, 31 (70.5%) were confirmed to have peripheral neurogenic tumors, and 13 (29.5%) carried non-neurogenic lesions. A total of 15 misdiagnoses occurred (34.1% of the cohort). Thirteen misdiagnoses represented source misjudgment, in which all non-neurogenic lesions were incorrectly categorized as neurogenic; these predominantly included five lipogenic tumors, four fibrogenic lesions, and four other miscellaneous soft tissue masses. Two misdiagnoses were subtype misjudgments of confirmed neurogenic tumors (6.5% of all neurogenic cases). Importantly, this cohort only included atypical confusing lesions without classic imaging features; the 0% specificity of the combined ultrasound criteria only reflects ultrasound performance in difficult cases and cannot be extended to routine pediatric superficial masses. The rat-tail sign yielded 100% specificity (95% confidence interval (CI): 75.3%-100%) and 100% positive predictive value (95% CI: 73.5%-100%) for identifying neurogenic lesions, while its sensitivity was only 38.7% (12/31; 95% CI: 21.8%-57.8%). The rat-tail sign achieves 100% specificity and positive predictive value for neurogenic lesions within this atypical cohort, yet shows only 38.7% sensitivity. Major pitfalls include pseudo-rat-tail artifacts and mimicking lesions. Integrating patient age, growth velocity, and dynamic multiplanar tracing into a standardized stepwise workflow can reduce false-positive misdiagnoses in daily practice.
-
4. Fetal Structural Anomalies and Vasa Previa Newly Identified After an Unremarkable Mid-Trimester Systematic Ultrasound Screening: Clinical Significance and Follow-Up Findings in 47 Cases.
PMID:日期:2026-09-29Some fetal structural anomalies and cases of vasa previa may not be detectable until after mid-trimester ultrasound screening. This study evaluated the spectrum, sonographic features, and perinatal outcomes of these newly detected abnormalities. We retrospectively reviewed 14 579 singleton pregnancies that underwent standardized mid-trimester ultrasound screening with no structural abnormalities detected at that time. Among these, 47 fetuses had anomalies newly identified before delivery. One additional pregnancy, in which multiple malformations were already detected at mid-trimester screening, was encountered during the same period. Because this case did not meet the inclusion criterion of an unremarkable mid-trimester scan, it was not included in the primary cohort and is described separately. The detection proportion was 3.22 per 1000 pregnancies (47). Digestive and hepatobiliary anomalies accounted for 25.5% (12), followed by central nervous system anomalies 23.4% (11). Vasa previa was diagnosed in three pregnancies 6.4% (3). A total of 14 pregnancies were terminated. Four live-born infants died during the neonatal period; 21.3% (10) underwent surgery. A total of 8 of 10 surgically treated infants survived to hospital discharge. The overall survival to discharge was 61.7% (29). Supplementary ultrasound after mid-trimester screening can identify additional fetal structural anomalies and vasa previa and may inform prenatal counseling, delivery planning, and neonatal management.
-
5. Clinical and Ultrasound Characteristics of High-Grade Endometrial Stromal Sarcoma.
5. 高级别子宫内膜间质肉瘤的临床与超声特征PMID:日期:2026-09-29To investigate the clinical features, ultrasound manifestations and diagnostic value of high-grade endometrial stromal sarcoma (HGESS), analyze their correlation with pathological findings, and provide evidence for preoperative diagnosis, differential diagnosis and prognostic evaluation. A total of 36 patients with surgico-pathologically confirmed HGESS (2023-2026) were retrospectively enrolled. Control groups included 28 low-grade endometrial stromal sarcoma (LGESS) and 30 uterine leiomyosarcoma (ULMS). This retrospective singlecenter study followed the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) reporting checklist. Clinical, ultrasound, and pathological data were collected. Multivariate logistic regression with bootstrap internal validation, Receiver-operating characteristic (ROC) curves, Kappa test, Spearman's correlation, Kaplan-Meier survival analysis, and Log-rank test were performed. We acknowledged the potential overfitting risk for regression analysis given the limited sample size. The predominant symptoms of HGESS were irregular vaginal bleeding and lower abdominal distension and pain, with markedly shorter disease course than LGESS (p < 0.001). Serum LDH, CA125, and HE4 were significantly elevated in HGESS versus control groups (all p < 0.001). Typical ultrasound findings included ill-defined borders, heterogeneous hypoechogenicity, frequent internal necrosis and cystic degeneration, predominant Grade III blood flow and decreased resistance index (RI) (all p < 0.001). Multivariate logistic regression identified ill-defined borders, heterogeneous internal echo, Grade III blood flow and elevated LDH as independent risk factors for HGESS. Bootstrap internal validation supported model stability. The combined ultrasound-tumor-marker model yielded the area under the curve (AUC) = 0.918, sensitivity = 100%, specificity = 74.1%. Caution should be exercised interpreting this high diagnostic performance given singlecenter retrospective design and sample-size limitation. Lesion maximum diameter (r = 0.621, p < 0.001) and blood-flow abundance (r = 0.584, p < 0.001) positively correlated with the degree of histological malignancy. Shorter progression-free survival (PFS) was observed for patients with lesion > 5 cm (p < 0.001), RI < 0.40 (p = 0.003), and lymph-node metastasis (p < 0.001) in Log-rank tests. HGESS is highly malignant with rapid progression and characteristic ultrasound signs. Combined ultrasound and tumor-markers improve preoperative differential diagnosis. Ultrasound parameters provide prognostic clues for HGESS.
-
6. Point-Of-Care Ultrasound for the Assessment of the Cerebroplacental Ratio in Near-Term Pregnancies: An Agreement Study With Conventional Ultrasound.
PMID:日期:2026-09-25The cerebroplacental ratio (CPR) is associated with perinatal mortality and morbidity, and its measurement has been proposed in uncomplicated pregnancies near term to identify fetuses at risk of adverse outcome. A major limitation to its widespread adoption is the lack of ultrasound equipment dedicated to antepartum clinics. Point-of-care ultrasound (POCUS) has emerged as an affordable bedside tool that may overcome this limitation, but no comparative studies between POCUS and conventional ultrasound systems have been conducted for the evaluation of CPR. Our aim was to assess the level of agreement between these two devices in the evaluation of CPR. In a prospective cross-sectional study we examined singleton pregnancies between 36 and 38 weeks of gestation. In half of the participants the acquisition was repeated a second time by the same operator on the same device in order to quantify intra-observer reproducibility. Two observers performed Doppler recordings in a randomized sequence, each blinded to the other's results, one using a handheld ultrasound device (POCUS; Q7, Esaote, Genoa, Italy) and the other a conventional ultrasound system (MyLab Omega, Esaote, Genoa, Italy). Doppler waveforms were acquired in the absence of fetal movements and during maternal apnoea. The umbilical artery pulsatility index (UA PI) and the middle cerebral artery PI (MCA PI) were measured and the CPR was calculated as MCA PI/UA PI. A third obstetrician, blinded to the device and to the operator, assessed the quality of the recordings, assigning a score from 0 to 3 for both image quality (IQS) and measurement quality (MQS). Agreement was quantified with the intraclass correlation coefficient (ICC) and the Bland-Altman method. Eighty women participated in the study. Mean values did not differ between conventional ultrasound and POCUS for UA PI (1.04 ± 0.17 vs. 1.04 ± 0.20, p = 0.760), MCA PI (1.63 ± 0.22 vs. 1.65 ± 0.26, p = 0.113) or CPR (1.61 ± 0.34 vs. 1.65 ± 0.42, p = 0.137). The ICC between the two devices was 0.89 (95% CI 0.83-0.93) for UA PI, 0.85 (95% CI 0.78-0.90) for MCA PI and 0.84 (95% CI 0.77-0.90) for CPR. Bland-Altman analysis showed a negligible bias, with limits of agreement ranging from -0.45 to +0.38 for the CPR. Intra-observer reproducibility, assessed on two consecutive recordings in 40 of these women, yielded an ICC of 0.90 (95% CI 0.82-0.95) for UA PI, 0.85 (95% CI 0.73-0.92) for MCA PI and 0.85 (95% CI 0.74-0.92) for CPR, with no difference in within-subject variability between the two devices. There were no significant differences between conventional ultrasound and POCUS in IQS for UA PI (2.45 vs. 2.52, p = 0.343) or MCA PI (2.41 vs. 2.30, p = 0.214), nor in MQS for UA PI (2.42 vs. 2.36, p = 0.466) or MCA PI (2.42 vs. 2.23, p = 0.083). POCUS and conventional ultrasound showed good agreement in the evaluation of the CPR at near term, with no systematic difference between devices and comparable image and measurement quality. The agreement between devices was of the same order as the intra-observer repeatability of the measurement itself, indicating that most of the observed discrepancy reflects the intrinsic variability of fetal Doppler rather than the handheld device. POCUS appears to be a reliable and affordable alternative for the assessment of fetal Doppler in the antenatal clinic.
-
7. Evaluating Cervical Length in Placenta Accreta Spectrum and Its Effects on Maternal and Fetal Outcomes: A Prospective Cohort Study.
7. 评估胎盘植入谱系疾病中的宫颈长度及其对母婴结局的影响:一项前瞻性队列研究PMID:日期:2026-09-21Placenta accreta spectrum (PAS) has high maternal morbidity and poor neonatal outcomes, although the best time for delivery is not clear. Cervical length (CL) may serve as a useful adjunct for risk stratification and individualized delivery planning in PAS pregnancies. To examine the association of serial cervical length measurement with delivery timing and maternal and neonatal outcomes in women with PAS. In this prospective cohort study at three university hospitals in Tehran, 41 pregnant women antenatally diagnosed with PAS had transvaginal sonographic CL measurements performed at 28, 32, and 34 weeks' gestation. The main outcome was gestational age at delivery and its connection with the CL. Maternal complications and neonatal morbidity constituted secondary outcomes. Short CL (< 25 mm) at 28 and 32 weeks was significantly related to delivery at ≤ 34 weeks (p < 0.05) and increased Cesarean hysterectomy rates (p = 0.002 at 32 weeks; p = 0.005 at 34 weeks). Emergent Cesarean delivery was more common among PAS patients with CL < 25 mm at 32 and 34 weeks (p = 0.02). Neonates from mothers with short CL had increased likelihood for antibiotics, surfactant, resuscitation, and intubation (all p < 0.05). No significant relations were seen for CL and intraoperative bladder damage or estimated blood loss. Cervical shortening in the late second and early third trimester in PAS women is significantly associated with earlier term delivery, increased risk of Cesarean hysterectomy, and neonatal morbidity for PAS pregnancies. Repeated assessments of CL may be a useful adjunct for individualizing delivery timing and optimizing maternal-fetal outcomes. Larger prospective multicenter trials are essential to validate the role of CL in risk stratification and to integrate it into an individualized delivery planning algorithm.
-
8. Role of Ultrasound in the Evaluation of Diabetics-Related Complication: A Systematic Review and Meta-Analysis.
8. 超声在糖尿病相关并发症评估中的作用:系统评价与荟萃分析PMID:日期:2026-09-21Diabetes mellitus is associated with a wide spectrum of macrovascular and microvascular complications affecting multiple organ systems. Ultrasound offers a noninvasive, accessible imaging modality for the early detection of these complications. This systematic review and meta-analysis evaluated the diagnostic role of ultrasound across diabetes-related complications, including nephropathy, neuropathy, hepatic fibrosis, carotid atherosclerosis, plantar fasciitis, and cardiac vascular alterations. Relevant studies were identified from PubMed, Scopus, and the Cochrane Library, supplemented by gray literature, and appraised using the Newcastle-Ottawa Scale. The meta-analysis was performed using Jamovi software in accordance with PRISMA guidelines. Pooled findings demonstrated that the renal resistive index (RI) measured by Doppler ultrasound was significantly elevated in diabetic nephropathy compared with controls. Plantar fascia thickness, peripheral nerve cross-sectional area, and liver stiffness were all significantly greater in diabetic patients than in non-diabetic controls (p < 0.05 across outcomes). Carotid intima-media thickness and vascular resistance parameters were also measurably increased, reflecting early atherosclerotic changes. These results confirm that ultrasound is a versatile and diagnostically valid tool across multiple diabetes-related complication domains, with particular strength in hepatic, neurological, renal, and musculoskeletal assessment. The consistent findings across organ systems support its integration into routine diabetic surveillance. Standardized acquisition protocols and larger prospective studies are needed to consolidate reference ranges and strengthen clinical applicability.
-
9. The Predictive Accuracy of Prenatal Ultrasound for Macrosomia-A Retrospective Cohort Study.
PMID:日期:2026-09-18This study aimed to evaluate the accuracy of third-trimester ultrasound for fetal macrosomia and to assess obstetric outcomes associated with its prenatal suspicion. Retrospective cohort study on women receiving prenatal care at a tertiary care hospital between November 2017 and December 2022. Singleton pregnancies with prenatal suspicion of macrosomia (estimated fetal weight ≥ 4000 g or > 90th percentile for gestational age) were included. Controls were singleton term deliveries without suspected macrosomia. Cases were categorized as true positives (TP) and false positives (FP), based on birthweight. Diagnostic accuracy for neonatal macrosomia was evaluated. Obstetric outcomes were compared between cases and controls, and between the TP and FP groups. A total of 365 patients received a prenatal suspicion of macrosomia during the study period, of whom 239 (65.48%) were classified as TP and 126 (34.52%) as FP. The FP rate did not differ significantly whether the ultrasound assessment was performed before or after 37 weeks. The prenatal suspicion of fetal macrosomia presented high specificity (98.49%) and negative predictive value (97.78%), but low sensitivity (63.75%) and positive predictive value (72.34%) for neonatal macrosomia. Additionally, a prenatal suspicion of macrosomia was strongly associated with labor induction (57.26% vs. 25.52% in the control group, p < 0.001), with 27.27% of inductions occurring before 39 weeks. Third-trimester fetal weight estimation has limited predictive accuracy for neonatal macrosomia, and sonographic suspicion of macrosomia is strongly associated with labor induction. These findings suggest that suspected prenatal macrosomia should not be used in isolation when planning obstetric management, including decisions regarding labor induction.
-
10. Relative Contributions of Alpha and Beta Angles to Age-Specific Graf Classification in Infant Hip Ultrasonography: A Retrospective Study.
PMID:日期:2026-09-15Because the age-specific Graf endpoint is itself defined by the alpha and beta angles, angle-based discrimination is inherently classification-internal rather than a measure of independent diagnostic accuracy. Within this framework, the relative contribution of alpha and beta angles to the classification was quantified. This single-center retrospective study included 313 infants examined from May 2025 to May 2026. The endpoint was Graf IIa or higher in infants younger than 3 months and Graf IIb or higher in infants aged 3 months or older. Logistic regression, receiver operating characteristic analysis, paired DeLong tests, bootstrap validation, side-level generalized estimating equations, an age interaction analysis, and bootstrap estimation of calibration slope and intercept were used. The endpoint was positive in 140 infants (44.7%). Worst alpha angle had an area under the curve of 0.904 (95% confidence interval, 0.867-0.940), versus 0.666 (95% confidence interval, 0.606-0.726) for worst beta angle and 0.903 for the multivariable model. Each 1° increase in worst alpha angle was associated with lower odds of endpoint positivity (odds ratio, 0.495; 95% confidence interval, 0.417-0.574; p < 0.001). Worst beta angle and sex were not independently associated. In a post hoc age interaction analysis, adding an age-by-worst-alpha term improved model fit (likelihood ratio test p = 0.026; Akaike information criterion 261.7-248.7), with an interaction odds ratio of 1.132 (95% confidence interval, 1.015-1.270; p = 0.030). Bootstrap calibration of the primary model showed an optimism-corrected slope of 0.976 (95% confidence interval, 0.706-1.251) and intercept of 0.009 (95% confidence interval, -0.274 to 0.326). Within the age-specific Graf framework, the worst alpha angle captured most of the classification-internal statistical information, whereas beta angle and sex added little discrimination, and model calibration was adequate. Because the endpoint is defined by the angles themselves, these findings describe the internal structure of the classification and do not establish diagnostic accuracy against an independent reference standard or justify omitting beta angle from a complete clinical Graf examination.