IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUESIEEE微波理论与技术汇刊
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES(英文缩写 IEEE T MICROW THEORY),ISSN 0018-9480,eISSN 1557-9670,中文译名:IEEE微波理论与技术汇刊 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.381 | Q2 |
| 2022 | 4.300 | Q2 |
| 2023 | 4.100 | Q2 |
| 2024 | 4.500 | Q2 |
| 2025 | 5.200 | Q1 |
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES 最新收录文献
-
1. System-Level Calibration of a Millimeter-Wave Vector Signal Analyzer with Uncertainties.
PMID:日期:2025-11We describe the system-level calibration of a vector signal analyzer operating at 28 GHz, including the determination of uncertainties in the magnitude and phase of measurements of a traceably characterized calibration waveform. We then apply the IEEE 1765-2022 measurement comparison approach to evaluate the uncertainty in error vector magnitude of the vector signal analyzer using an equivalent-time sampling oscilloscope with traceable calibration as the reference receiver. An additional measurement of the modulated waveform is made for comparison using a large-signal network analyzer operating on an arbitrary frequency grid, with good agreement to the sampling oscilloscope and vector signal analyzer in amplitude, phase, and error vector magnitude.
-
2. Glass Microwave Microfluidic Devices for Broadband Characterization of Diverse Fluids.
PMID:日期:2025-01We demonstrate a glass microwave microfluidic device for determining the permittivity of a wide range of liquid chemicals from 100 MHz to 30 GHz with associated uncertainties. Conventional microwave microfluidic devices use polymer-based microfluidic layers for fluid delivery, but these polymers swell in organic solvents and are not suitable for many applications. Our device incorporates glass microfluidic channels with platinum coplanar waveguides (CPWs) to provide a solvent-resistant architecture for broadband dielectric spectroscopy. We utilize broadband scattering parameter measurements with a vector network analyzer (VNA) on a wafer probing station and multiline thru-reflect-line (mTRL) calibrations to extract the distributed circuit parameters of transmission lines and solve for fluid permittivity. In this work, we demonstrate the utility of the device by measuring the permittivity of four organic solvents difficult to measure otherwise: hexane, heptane, decane, and toluene.
-
3. Miniaturized Wirelessly Powered and Controlled Implants for Multisite Stimulation.
3. 用于多位点刺激的微型化无线供电与可控植入物PMID:日期:2023-01-06This paper presents a miniaturized implant with a diameter of only 14 mm, which houses a novel System on Chip (SoC) enabling two voltage level stimulation of up to 16 implants using a single Tx coil. Each implant can operate at a distance of 80 mm in the air through the inductive resonant link. The SoC consumes only 27 W static power and enables two channels with stimulation amplitudes of 1.8 V and 3.3 V and timing resolution of 100 s. The SoC is implemented in the standard 180 nm complementary metal oxide semiconductor (CMOS) technology and has an area of 0.75 mm × 1.6 mm. The SoC comprises an RF rectifier, low drop-out regulator (LDO), error detection block, clock data recovery, finite state machine (FSM), and output stage. Each implant has a PCB-defined passcode, which enables the individual addressability of the implants for synchronized therapies. The implantable device weighs only 80 mg and sizes 20.1 . Tolerance of up to 70° to angular misalignment was measured at a distance of 50 mm. The efficacy of bilateral stimulation was further verified by implanting two devices on two sides of a pig's neck and performing bilateral vagus nerve stimulation (VNS), while monitoring the heart rate.
-
4. Galvanic-coupled Trans-dural Data Transfer for High-bandwidth Intra-cortical Neural Sensing.
PMID:日期:2022-08-22A digital-impulse galvanic coupling as a new high-speed trans-dural (from cortex to the skull) data transmission method has been presented in this paper. The proposed wireless telemetry replaces the tethered wires connected in between implants on the cortex and above the skull, allowing the brain implant to be "free-floating" for minimizing brain tissue damage. Such trans-dural wireless telemetry must have a wide channel bandwidth for high-speed data transfer and a small form factor for minimum invasiveness. To investigate the propagation property of the channel, a finite element model is developed and a channel characterization based on a liquid phantom and porcine tissue is performed. The results show that the trans-dural channel has a wide frequency response of up to 250 MHz. Propagation loss due to micro-motion and misalignments is also investigated in this work. The result indicates that the proposed transmission method is relatively insensitive to misalignment. It has approximately 1 dB extra loss when there is a horizontal misalignment of 1mm. A pulse-based transmitter ASIC and a miniature PCB module are designed and validated ex-vivo with a 10-mm thick porcine tissue. This work demonstrates a high-speed and miniature in-body galvanic-coupled pulse-based communication with a data rate up to 250 Mbps with an energy efficiency of 2 pJ/bit, and has a small module area of only 26 mm.
-
5. Near-Field Microwave Scattering Formulation by A Deep Learning Method.
PMID:日期:2022-06-29A deep learning method is applied to modelling electromagnetic (EM) scattering for microwave breast imaging (MBI). The neural network (NN) accepts 2D dielectric breast maps at 3 GHz and produces scattered-field data on an antenna array composed of 24 transmitters and 24 receivers. The NN was trained by 18,000 synthetic digital breast phantoms generated by generative adversarial network (GAN), and the scattered-field data pre-calculated by method of moments (MOM). Validation was performed by comparing the 2,000 NN-produced datasets isolated from the training data with the data computed by MOM. Finally, data generated by NN and MOM were used for image reconstruction. The reconstruction demonstrated that errors caused by NN would not significantly affect the image result. But the computational speed of NN was nearly 10 times faster than the MOM, indicating that deep learning has the potential to be considered as a fast tool for EM scattering computation.
-
6. Real-Time mmWave Channel Sounding Through Switched Beamforming With 3-D Dual-Polarized Phased-Array Antennas.
6. 通过开关波束成形与三维双极化相控阵天线进行实时毫米波信道探测PMID:日期:2021-11We propose a 28.5-GHz channel sounder that switches through all antennas of multiple dual-polarized 8 × 8 phased arrays at the transmitter and receiver and performs beamforming in postprocessing through digital weights to synthesize a sweepable beam. To our knowledge, we are the first to implement-what we refer to as- with phased arrays for millimeter-wave channel sounding, realized through highly stable Rubidium clocks and local oscillators coupled with precision over-the-air calibration techniques developed in house. By circumventing the time-consuming programming of analog weights that is associated with analog beamforming-what phased arrays are designed for-we can sweep a 3-D double-omnidirectional dual-polarized channel in just 1.3 ms, for real-time sounding. By in turn circumventing the coarse precision of analog weights, we can synthesize ideal beam patterns thanks to the effectively infinite precision of digital weights, enabling fine weight calibration for the nonidealities of the system hardware and fine weight tapering for sidelobe suppression. This translates to average estimation errors of 0.47° in 3-D double-directional angle, 0.48 dB in co-polarized path gain, and 0.18 ns in delay, as substantiated by field measurements.
-
7. Research on Dry Microwave Heating Infectious Aerosols or Droplets on Respirators.
PMID:日期:2021-06-18Dramatic shortages of filtering facepiece respirator supplies generally occur following the outbreak of a pandemic such as COVID-19. Here, the decontamination and reuse of respirators are considered. Among decontamination methods, microwave irradiation has great potential because of easy access of microwave ovens. However, can a respirator be heated in a microwave oven for a certain time and then be reused? Herein, we demonstrate that dry microwave irradiation cannot heat infectious aerosols or droplets up to their deactivation temperature. The microwave absorption performance of a single aerosol or droplet was analyzed theoretically. The multiphysics simulation results indicate that a single aerosol or droplet can be barely heated under dry microwave irradiation. Experiments were carried out using a traveling wave system to verify the simulation. Following this, we simulated multiple aerosols and droplets on a respirator material, with the results indicating that the aerosols and droplets were at the same temperature as that of the respirator. Experimental measurements using a microwave oven demonstrated that the temperature increase of an N95 respirator under dry heating is less than 10 °C, which is far less than the temperature required to deactivate the COVID-19 virus. Although dry microwave heating cannot be used to heat the aerosols or droplets, microwave-generated steam has proved effective in deactivating infectious biological organisms. Therefore, to successfully decontaminate a used respirator in a microwave oven, a reservoir with a small amount of water beneath the respirator (or a steam bag to accommodate it) is essential to the decontamination process.
-
8. A Wireless Artificial Mechanoreceptor in 180-nm CMOS.
PMID:日期:2021-04-22This article presents an implantable low-power wireless integrated system for tactile sensing applications. The reported ASIC utilizes a low-loss magnetic human body communication channel for both wireless power and data transfer. The chip is hybrid-integrated with an in-house fabricated MEMS capacitive force sensor to form an implantable artificial mechanoreceptor. An on-chip correlated double sampling capacitance to time converter consumes 750nW from a 1.2V on-chip regulated supply, achieving a 2.0fF resolution for an input capacitance of 14pF and a FoM of 49 fJ/c-s while occupying an area of only 0.04 mm. The capacitance to time converter has a time-multiplexed mode to interface with 4 input capacitors. Wireless power management feedback is utilized to ensure robust operation in the presence of hand gesture changes and process-voltage-temperature variations. The on-chip data transmitter can operate in on-off keying or frequency-shift keying modulation formats, where it consumes only 7.8 in the on-off keying mode. The 1.62mm chip is fabricated in a standard 180nm CMOS process and consumes 110.3 .
-
9. Discrete Dipole Approximation-Based Microwave Tomography for Fast Breast Cancer Imaging.
9. 基于离散偶极近似的用于快速乳腺癌成像的微波层析成像技术PMID:日期:2021-03-05This paper describes a fast microwave tomography reconstruction algorithm based on the two-dimensional discrete dipole approximation. Synthetic data from a finite-element based solver and experimental data from a microwave imaging system are used to reconstruct images and to validate the algorithm. The microwave measurement system consists of 16 monopole antennas immersed in a tank filled with lossy coupling liquid and a vector network analyzer. The low-profile antennas and lossy nature of system make the discrete dipole approximation an ideal forward solver in the image reconstructions. The results show that the algorithm can readily reconstruct a 2D plane of a cylindrical phantom. The proposed forward solver combined with the nodal adjoint method for computing the Jacobian matrix enables the algorithm to reconstruct an image within 6 seconds. This implementation provides a significant time savings and reduced memory requirements and is a dramatic improvement over previous implementations.
-
10. Evaluating Uncertainty of Nonlinear Microwave Calibration Models with Regression Residuals.
PMID:日期:2020-09We investigate the performance of a recently developed algorithm that evaluates the uncertainty of nonlinear multivariate microwave calibration models using regression residuals. We apply the algorithm to synthetic data consisting of both random and systematic errors and show that the algorithm can account for both types of errors even in the absence of accurate models for the random errors. We also verify the algorithm with measured data.