IEEE TRANSACTIONS ON MAGNETICSIEEE磁学汇刊
IEEE TRANSACTIONS ON MAGNETICS(英文缩写 IEEE T MAGN),ISSN 0018-9464,eISSN 1941-0069,中文译名:IEEE磁学汇刊 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.848 | Q3 |
| 2022 | 2.100 | Q3 |
| 2023 | 2.100 | Q3 |
| 2024 | 1.900 | Q3 |
| 2025 | 1.900 | Q3 |
IEEE TRANSACTIONS ON MAGNETICS 最新收录文献
-
1. Novel Volume Integral Equation Approach for Low-Frequency E-Field Dosimetry of Transcranial Magnetic Stimulation.
1. 用于经颅磁刺激低频电场剂量学的新型体积分方程方法PMID:日期:2024-10-24A new volume integral equation (VIE) approach is introduced to study transcranial magnetic stimulation (TMS) and high-contrast media at low frequencies. This new integral equation offers a simple solution to the high-contrast breakdown observed in low-frequency electric field (E-field) dosimetry of conductive media. Specifically, we employ appropriate approximations that are valid for low frequencies and stabilize the VIE by introducing a basis expansion set that removes solutions associated with high eigenvalues in the equation. The new equation is devoid of high-contrast breakdown and does not require the use of auxiliary surface variables or projectors, providing a straightforward practical solution for the VIE analysis of TMS. Our results indicate that the novel VIE formulation matches boundary element, finite element, and analytical solutions. This new VIE represents a first step towards including anisotropy in integral equation E-field dosimetry for brain stimulation.
-
2. Bioapplications of Magnetic Nanowires: Barcodes, Biocomposites, Heaters.
2. 磁性纳米线的生物应用:条形码、生物复合材料、加热器PMID:日期:2022-02-23Magnetic nanowires (MNWs) can have their moments reversed via several mechanisms that are controlled using the composition, length, diameter, and density of nanowires in arrays as-synthesized or as individual nanoparticles in assays or gels. This tailoring of magnetic reversal leads to unique properties that can be used as a signature for reading out the type of MNW for applications as nano-barcodes. When synthesized inside track-etched polycarbonate membranes, the resulting MNW-embedded membranes can be used as biocompatible bandaids for detection without contact or optical sighting. When etched out of the growth template, free-floating MNWs are internalized by cells at 37 °C such that cells and/or exosomes can be collected and detected. In applications of cryopreservation, MNWs can be suspended in cryopreservation agents (CPAs) for injection into the blood vessels of tissues and organs as they are vitrified to -200 °C. Using an alternating magnetic field, the MNWs can then be nanowarmed rapidly to prevent crystallization and uniformly to prevent cracking of specimens, for example, as grafts or transplants. This invited paper is a review of recent progress in the specific bioapplications of MNWs to barcodes, biocomposites, and nanowarmers.
-
3. 1D imaging of a superparamagnetic iron oxide nanoparticle distribution by a single-sided FFL magnetic particle imaging scanner.
3. 单侧FFL磁粒子成像扫描仪对超顺磁性氧化铁纳米颗粒分布的一维成像PMID:日期:2022-02-15Magnetic Particle Imaging (MPI) is an emerging imaging modality that has a potential of complimenting other imaging modalities in clinical practice. Despite many efforts to scale up MPI hardware to date no MPI systems have been demonstrated to accommodate full body imaging. Previously, we introduced hardware and characterized a prototype of a single-sided MPI scanner, where all coils are confined to a single-side of the device, which provides a subject with unrestricted access to the scanning area although with a limited penetration depth. The major difference in our design from the first reported single-sided scanner is in incorporating a field-free line instead of a field-free point, which generally promises higher sensitivity and more robust image reconstruction. However, as inherent to any single-sided configurations the fields in our device are spatially inhomogeneous making it challenging to apply existing imaging techniques. For our specific geometry we implemented spatial encoding scheme and imaging in time-domain making the image reconstruction fast. In this work we present one dimensional imaging of multiple rods phantoms with a single-sided field-free line MPI scanner. The results demonstrate that our scanner is capable of one dimensional imaging of phantoms with a spatial resolution of at least 7 mm without image processing.
-
4. Characterization of Ferromagnetic Composite Implants for Tumor Bed Hyperthermia.
PMID:日期:2021-07-16Hyperthermia therapy (HT) is becoming a well-recognized method for the treatment of cancer when combined with radiation or chemotherapy. There are many ways to heat a tumor and the optimum approach depends on the treatment site. This study investigates a composite ferromagnetic surgical implant inserted in a tumor bed for the delivery of local HT. Heating of the implant is achieved by inductively coupling energy from an external magnetic field of sub-megahertz frequency. Implants are formed by mechanically filling a resected tumor bed with self-polymerizing plastic mass mixed with small ferromagnetic thermoseeds. Model implants were manufactured and then heated in a 35 cm diameter induction coil of our own design. Experimental results showed that implants were easily heated to temperatures that allow either traditional HT (39-45°C) or thermal ablation therapy (>50°C) in an external magnetic field with a frequency of 90 kHz and amplitude not exceeding 4 kA/m. These results agreed well with a numerical solution of combined electromagnetic and heat transfer equations solved using the finite element method.
-
5. {"_":"An ON-OFF Magneto-Optical Probe of Anisotropic Biofluid Crystals: A -Hematin Case Study.","i":["β"]}
5. {"_":"各向异性生物流体晶体的开关式磁光探针:以β-血红素为例的研究。","i":["β"]}PMID:日期:2021-07-09We have designed, developed and evaluated an innovative portable magneto-optical detector (MOD) in which a light beam with variable polarization passes through a fluid sample immersed in a variable magnetic field. The light intensity is measured downstream along the forward scattering direction. The field is turned on and off through the in-and-out motion of nearby permanent magnets. As a result, for sufficiently magnetically and optically anisotropic samples, the optical absorption is sensitive to changes in the light polarization. Both detection and characterization applications are therefore available. For instance, both the degree of malaria infection can be measured and hemozoin crystalline properties can be studied. We present experimental results for synthetic hemozoin, and describe them in terms of the basic physics and chemistry underlying the correlations of the directions of the external magnetic field and the light beam polarization. We connect this work to a commercialized product for malaria detection and compare it to other magneto-optical instruments and methods. We conduct tests of absorption parameters, the electric polarizability tensor, and we discuss the connection to magnetic and electric dipole moments.
-
6. Roadmap of spin-orbit torques.
6. 自旋轨道扭矩路线图PMID:日期:2021Spin-orbit torque (SOT) is an emerging technology that enables the efficient manipulation of spintronic devices. The initial processes of interest in SOTs involved electric fields, spin-orbit coupling, conduction electron spins and magnetization. More recently interest has grown to include a variety of other processes that include phonons, magnons, or heat. Over the past decade, many materials have been explored to achieve a larger SOT efficiency. Recently, holistic design to maximize the performance of SOT devices has extended material research from a nonmagnetic layer to a magnetic layer. The rapid development of SOT has spurred a variety of SOT-based applications. In this Roadmap paper, we first review the theories of SOTs by introducing the various mechanisms thought to generate or control SOTs, such as the spin Hall effect, the Rashba-Edelstein effect, the orbital Hall effect, thermal gradients, magnons, and strain effects. Then, we discuss the materials that enable these effects, including metals, metallic alloys, topological insulators, two-dimensional materials, and complex oxides. We also discuss the important roles in SOT devices of different types of magnetic layers, such as magnetic insulators, antiferromagnets, and ferrimagnets. Afterward, we discuss device applications utilizing SOTs. We discuss and compare three-terminal and two-terminal SOT-magnetoresistive random-access memories (MRAMs); we mention various schemes to eliminate the need for an external field. We provide technological application considerations for SOT-MRAM and give perspectives on SOT-based neuromorphic devices and circuits. In addition to SOT-MRAM, we present SOT-based spintronic terahertz generators, nano-oscillators, and domain wall and skyrmion racetrack memories. This paper aims to achieve a comprehensive review of SOT theory, materials, and applications, guiding future SOT development in both the academic and industrial sectors.
-
7. Single-Sided Magnetic Particle Imaging Device with Field-Free-Line Geometry for in-vivo Imaging Applications.
PMID:日期:2020-07-10Magnetic Particle Imaging (MPI) has shown great promise to surpass existing in vivo imaging modalities in some clinical applications. However, one of the challenges to MPI being translated into clinical practice has been the ability to scale up the selection field coils to surround a human body while being able to generate and drive a sufficiently strong magnetic field gradient. These requirements impose safety concerns as well as prohibitively high-power consumption in devices with large cylindrical volume. Therefore, we consider an alternative approach such as a single-sided topology, in which all the hardware is located on one side of the imaging volume accommodating larger subjects. Moreover, different from the previously implemented field-free point single-sided scanners, we realized a field-free line geometry providing, in principle, factor of ten higher signal and benefiting from a more robust back-projection image reconstruction technique. In this work, we present and characterize a first prototype of a single-sided MPI device with field-free-line geometry suited for in-vivo imaging of small animals as well as regions of interest in humans.
-
8. {"_":"Effect of oblique versus normal deposition orientation on the properties of perpendicularly magnetized L1 FePd thin films.","sub":["0"]}
PMID:日期:2020Materials such as L1 Fe-based alloys with perpendicular magnetic anisotropy derived from crystal structure have the potential to deliver higher thermal stability of magnetic memory elements compared to materials whose anisotropy is derived from surfaces and interfaces. A number of processing parameters enable control of the quality and texture of L1 FePd among them, including substrate, deposition temperature, pressure and seed and buffer layer. The angle of inclination between the substrate and the sputtering target can also impact the texture of L1 crystallization of sputtered Fe-Pd and magnetic properties of the derived thin films. This study examines the difference between FePd layers that have been magnetron sputter deposited on Cr(15 nm)/Pt, Ir, or Ru(4 nm)/FePd (8 nm)/Ru(2 nm)/Ta(3 nm) substrate layers at an oblique angle (30° tilt from the sputtering target) versus normal incidence (target facing the substrate). X-ray diffraction, ferromagnetic resonance spectroscopy and vibrating sample magnetometry were used to compare the degree of L1 order and static and dynamic properties of films deposited under both conditions. The films grown using the oblique orientation exhibit a stronger degree of L1 orientation, a larger magnetic anisotropy energy and a lower Gilbert damping, on all three buffer layers.
-
9. Improvement of Reproducibility of Magnetic Moment Detected by a SQUID Magnetometer Through Radial Offset Measurement on a YIG Sphere.
9. 通过YIG球体径向偏移测量提高SQUID磁强计检测磁矩的再现性PMID:日期:2019-02We report here on the reproducibility of measurements on a second-order gradiometer superconducting quantum interference device magnetometer of two different yttrium iron garnet spheres, both having a diameter of 1 mm: 1) the National Institute of Standards and Technology magnetic moment standard reference material (SRM) and 2) a commercial sample. It has been suggested that rotating the sample rod around its axis can move the sample center toward the center of the second-order gradiometer coil. The observed value of the magnetic moment will be theoretically a minimum when the radial offset is 0, and this value will increase in a "quadratic" manner with the radial offset. When the magnetic moment of the SRM was repeatedly measured as a function of rotation angle from 0° to 360°, we observed a sinusoidal variation in the measured values. The radial offset dependence of the observed magnetic moment was experimentally confirmed by the measurements of the commercial sphere placed in a hole in several cylindrical containers, wherein the distance between the center of the hole and the center of the container was . The -dependence of the minimum from each -dependent measurement series is qualitatively consistent with the theoretical curve. When the -dependent measurements for the SRM in a capsule were repeated 12× over 21 months, the relative standard deviation of the minimums improved up to 0.1%. Knowledge of these facts will be necessary for the accurate measurement of the magnetic moment of other sample forms (e.g., powders).
-
10. Electrically Small Dipole Antenna Probe for Quasistatic Electric Field Measurements in Transcranial Magnetic Stimulation.
PMID:日期:2018-11-02The present paper designs, constructs, and tests an electrically small dipole antenna probe for the measurement of electric field distributions with the ultimate purpose to directly measure electric fields induced by a transcranial magnetic stimulation (TMS) coil. Its unique features include applicability to measurements in both air and conducting medium, high spatial resolution, large frequency band from 100 Hz to 300 KHz, efficient feedline isolation via a printed Dyson balun, and accurate mitigation of noise. Prior work in this area is thoroughly reviewed. The proposed probe design is realized in hardware; implementation details and design tradeoffs are described. Test data are presented for the measurement of a constant wave capacitor electric field, demonstrating the probe's ability to properly measure electric fields caused by a charge distribution. Test data are also presented for the measurement of a constant wave solenoidal electric field, demonstrating the probe's ability to measure electric fields caused by Faraday's law of induction. Those are the primary fields for the transcranial magnetic stimulation. Further steps necessary for the application of this probe as an instrument for TMS coil design are discussed.