ANALYTICAL CHEMISTRY分析化学
ANALYTICAL CHEMISTRY(英文缩写 ANAL CHEM),ISSN 0003-2700,eISSN 1520-6882,中文译名:分析化学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 8.008 | Q1 |
| 2022 | 7.400 | Q1 |
| 2023 | 6.700 | Q1 |
| 2024 | 6.700 | Q1 |
| 2025 | 7.300 | Q1 |
ANALYTICAL CHEMISTRY 最新收录文献
-
1. Errors in the Laboratory X-ray Absorption Near Edge Structure with Respect to Species Analysis in Slags Considering Leak Radiation.
1. 实验室X射线吸收近边结构在炉渣中物种分析方面考虑泄漏辐射的误差PMID:日期:2026-09-30The knowledge on the element species in slags is of great importance for, e.g., process control or recovery of valuable materials. X-ray absorption near-edge spectroscopy (XANES) is a suitable method, especially for slags, since it allows element speciation not only in crystalline but also in amorphous phases. The sample preparation as well as the evaluation via linear combination fitting of reference spectra are relevant influencing factors for the results. Errors can occur due to, e.g., improperly prepared samples, damping effects, and inappropriate reference materials. In this study, the origin of spectral damping was investigated with two lab-based spectrometers on a sample series of Fe2O3 prepared as pellets with different masses. Additionally, an electric arc furnace (EAF) slag served as a complex model sample to determine the influence of dampened spectra on the speciation analysis through linear combination fitting. Powder X-ray diffraction (PXRD), X-ray fluorescence spectrometry (XRF), electron probe microanalysis (EPMA), and inductively coupled plasma optical emission spectroscopy (ICP-OES) were employed as complementary and supporting characterization methods.
-
2. Analysis of N-Glycans Released from Glycosylated RNAs.
2. 从糖基化RNA中释放的N-聚糖分析PMID:日期:2026-09-23Glycosylated RNAs (glycoRNAs) are involved in immune response, cellular function, gene regulation, and disease development. We report a liquid chromatography-mass spectrometry (LC-MS) method to analyze glycans released from glycoRNAs. The developed method includes extracting RNA from mouse liver using TRIzol, digesting proteins with proteinase K under denaturing conditions, re-extracting RNA using TRIzol, releasing N-glycans by enzymatic digestion, enriching glycans by solid-phase extraction, and analyzing glycans by LC-MS. The method was optimized to detect low-abundance N-glycans from a purchased mixture of N-glycan standards, and 65 glycans were identified. We then applied the method to analyze the glycans released from the glycoRNAs in mouse liver and identified 244 N-glycans from triplicate analyses. We also detected 40 significantly changed N-glycans in the livers of 32-week-old female and male KvB2 mice. This study establishes a simple and efficient technique for characterizing N-glycans in glycoRNAs and paves the way for future studies to understand the function of glycoRNAs.
-
3. Hybrid Photoacoustic Approach for Simultaneous Methane and Hydrogen Detection via Optical Absorption and Acoustic Frequency Tracking.
3. 基于光吸收与声频跟踪的混合光声方法用于甲烷和氢气的同时检测PMID:日期:2026-09-23Trace detection of methane (CH4) and hydrogen (H2) is critical for energy infrastructure monitoring and safety management. However, conventional photoacoustic spectroscopy (PAS) approaches rely primarily on optical absorption and often require carrier gases or complex configurations for H2 detection. Here, we report a hybrid photoacoustic sensing strategy that combines optical absorption-based detection with acoustic property tracking, enabling simultaneous and carrier-gas-free detection of CH4 and H2. In this approach, CH4 is quantified using second harmonic (2f) wavelength modulation spectroscopy, while H2 is detected via first harmonic (1f) frequency tracking based on sound-speed-induced resonance shifts. A multi-pass resonant photoacoustic cell is employed to enhance sensitivity, and in situ temperature compensation is achieved using a fiber Bragg grating (FBG) array to mitigate temperature-dependent variation in the acoustic response. The system achieves minimum detection limits of 17.7 ppb for CH4 and 1.39 ppm for H2 at an integration time of 100 s, without the use of carrier gases. The normalized noise equivalent absorption coefficient for CH4 detection reaches 1.07 × 10-9 cm-1·W·Hz-1/2. This hybrid sensing framework provides a generalizable approach for multi-gas detection by integrating optical and thermodynamic sensing mechanisms, offering a new pathway for high-sensitivity and robust gas analysis in complex environments.
-
4. "Turn-On" Nanoprobe for Stage-Differential Imaging of Inflammatory Bowel Disease.
4. 用于炎症性肠病分期差异成像的“开启型”纳米探针PMID:日期:2026-09-23Inflammatory bowel disease (IBD) is a chronic intestinal disorder with increasing incidence globally. Accurate assessment of its progression is essential for clinical management but remains challenging. Herein, we report a GzmA-activatable near-infrared (NIR) nanoprobe IR780 NP@S100 for stage-differential imaging of DSS-induced acute colitis. A molecular precursor, Cys(StBu)-Gly-Phe-Phe-Arg-Lys(IR780)-CBT (IR780-CBT), was designed to prepare the fluorescence-quenched nanoparticle IR780 NP in vitro with a CBT-Cys click reaction. In the presence of granzyme A (GzmA), a serine protease associated with IBD, IR780 NP was disassembled to turn the NIR fluorescence "On". For in vivo application, IR780 NP was encapsulated in Eudragit S100 to afford IR780 NP@S100 which stabilized the nanoparticle in the stomach but specifically released it in the colon. For IBD mouse models at an early stage (day 4) with higher expression of GzmA, IR780 NP showed higher "On" fluorescence in their colons. However, it showed lower "On" fluorescence in the colons of IBD mice at the late stage (day 8). Moreover, IR780 NP enabled fecal fluorescence analysis of IBD, providing a complementary noninvasive readout for monitoring colitis progression. We anticipate that IR780 NP@S100 can be applied for stage-differential imaging of acute colitis in the clinic in the near future.
-
5. Gas Sensing Based on Heterodyne Mach-Zehnder Interferometric Phase-Dispersion Spectroscopy.
5. 基于外差马赫-曾德尔干涉相位色散光谱的气体传感技术PMID:日期:2026-09-22A novel gas sensing method based on heterodyne Mach-Zehnder interferometric phase-dispersion spectroscopy (HMIPDS) was proposed for the first time in this work. The proposed method employed a heterodyne Mach-Zehnder interferometric configuration to realize gas sensing through cumulative optical phase shifts induced by refractive-index variations during laser-gas interaction. Specifically, the laser beam was divided into a signal arm interacting with the gas medium and a reference arm frequency-shifted by an acousto-optic modulator (AOM) to generate heterodyne interference. The gas-induced optical phase variation was then accurately extracted via quadrature demodulation of the interference signal, thereby enabling quantitative retrieval of gas concentration. Acetylene (C2H2) was used for experimental validation. Experimental results demonstrate the HMIPDS method achieved a detection limit of 708 ppb with an integration time of 500 s, corresponding to an approximately 11-fold improvement in detection sensitivity compared with the conventional WMS-2f detection system (8 ppm at 500 s). Furthermore, the linear dynamic detection range was extended from 0 to 2% for conventional WMS-2f to 0-5%, corresponding to an approximately 2.5-fold enhancement. The proposed HMIPDS method provides a high sensitivity, high stability, and wide dynamic range solution for gas sensing, showing strong potential for high-concentration and ultrasensitive trace gas detection applications.
-
6. Beyond In Vitro Brightness: A Matched-Probe Study of Chemiluminescence Contrast for In Vivo Peroxynitrite Imaging.
6. 超越体外亮度:用于体内过氧亚硝酸盐成像的化学发光对比度的匹配探针研究PMID:日期:2026-09-18Probe selection for in vivo chemiluminescence imaging commonly relies on intensity and tissue-overlay measurements performed in vitro, yet these measurements do not reproduce the activation background, probe distribution, and optical environment of a living animal. Here, we test how measurement context affects probe ranking using two ONOO--responsive bicyclic dioxetanes, Probe 1 and Probe 2, that share the same arylboronate trigger and closely related core architecture but emit at different wavelengths. In black 96-well plates after ONOO- activation, the visible-emitting Probe 2 produced approximately 350-fold greater photon output than Probe 1, and Probe 2 retained the larger signal-to-background ratio in a chicken-tissue overlay experiment. These in vitro and ex vivo measurements would both favor Probe 2. In living mice, however, the ranking by analytical contrast changed. Probe 1 afforded a subcutaneous signal-to-background ratio of 489 and produced an approximately 7-fold challenged-to-control contrast in an Escherichia coli-induced peritonitis model, compared with approximately 1.5-fold for Probe 2, the absolute signal difference narrowed to approximately 3-fold. This environment-dependent reordering shows that plate intensity and tissue overlays alone can misrank probes intended for in vivo analysis. Emission wavelength, preactivation background, tissue transmission, and model-specific signal distribution must be evaluated together.
-
7. Fragment-Resolved Carbon and Hydrogen Isotope Analysis of Urinary Steroids by Orbitrap Mass Spectrometry.
7. 通过静电场轨道阱质谱法对尿液类固醇进行片段分辨的碳氢同位素分析PMID:日期:2026-09-14Compound-specific stable isotope analysis (CSIA) is widely used to distinguish sources and transformation pathways of organic compounds. In steroid CSIA each analyte is represented by a single molecular-average isotope value, which can limit discrimination when sources overlap in isotopic composition. This limitation is especially important in anti-doping analysis, where molecular-average δ13C measurements can be inconclusive for compounds whose C-isotope composition falls within the endogenous range. Here, we present an Orbitrap-based method for fragment-resolved intramolecular isotope analysis of steroids. Using urinary androsterone as a model analyte, we measured δ13C values for four diagnostic ions and δD for one fragment following controlled administration of androstenedione and testosterone undecanoate. The resulting multidimensional isotope fingerprints reveal responses not evident from bulk δ13C measurements alone, including cases in which administered androgen lies near the endogenous δ13C range. Time-dependent differences among fragment ions further suggest sensitivity to changes in metabolic routing and pool mixing during steroid transformation. These results establish fragment-resolved isotope analysis by Orbitrap mass spectrometry as a promising extension of conventional steroid CSIA and a potential new tool for forensic steroid source discrimination, with possible applications to environmental steroids and geological sterols and steranes.
-
8. Aptamer-Based Sensing with Fluorescent Light-Up DNA.
8. 基于适配体的荧光点亮DNA传感技术PMID:日期:2026-09-12DNA aptamers are widely used in the construction of fluorescent sensors, typically employing labelled fluorophores as signaling indicators. However, this covalent labeling approach suffers from several limitations, including complex and costly chemical modification, incompatibility with long aptamer sequences, and susceptibility to false-positive signals. To address these limitations, we constructed a novel aptamer-based fluorescent sensor using Lettuce indicator, a light-up DNA aptamer that adopts a precise three-dimensional structure, which enables it to selectively bind and activate the otherwise non-fluorescent small-molecule fluorophores. In our design, we destabilized Lettuce by fusing it with a target-binding aptamer via a transducer sequence. Upon target binding, structural rearrangement is triggered through the transducer, leading to the folding of Lettuce and restoration of its ability to activate the fluorophore, generating a target-dependent fluorescent signal. Through systematic optimization of the transducer and target-binding aptamer sequences, we created sensors for diverse targets, including small molecules, proteins, and metal ions. These sensors exhibit high signal-to-noise ratios, sensitivity and selectivity, and a wide dynamic range. As a proof-of-concept demonstration, a paper-based test strip for cost-effective and rapid detection of small molecule mycotoxins was developed. This versatile design provides a generalizable platform for the development of aptamer-based sensors, opening the way for future detection of diverse analytes.
-
9. Dual Amplification on Coordination-Engineered Photogate for Sensitive Organic Photoelectrochemical Transistor Biosensing.
9. 配位工程化光电门上的双重放大用于灵敏有机光电化学晶体管生物传感PMID:日期:2026-09-08MicroRNA (miRNA) analysis using organic photoelectrochemical transistor (OPECT) biosensors is often limited by insufficient photoelectric transduction efficiency and weak signal amplification. Herein, we develop a coordination heterojunction photogate-enabled OPECT biosensor combined with enzyme-free catalytic hairpin assembly and hybridization chain reaction (CHA-HCR) cascade amplification for ultrasensitive detection of miRNA-122. Interfacial Cu+-alkyne coordination between Cu2O and Cu-1,4-diethylenylbenzene facilitates charge transfer and photogenerated carrier separation, leading to enhanced photogating efficiency. Meanwhile, target miRNA-122 initiates sequential CHA and HCR reactions, producing extended DNA chains that accumulate at the gate/electrolyte interface and modulate the local charge environment, thereby amplifying the transistor response. The synergistic integration of coordination photogating and nucleic acid cascade amplification significantly improves analytical sensitivity (an ultralow detection limit of 0.26 fM) and selectivity toward miRNA-122. This strategy provides an effective route for constructing high-performance OPECT biosensors and broadens their applications in cancer biomarker detection.
-
10. Elucidating Antibody-Hapten Recognition for 25-Hydroxyvitamin D3 toward a Point-of-Need Immunoassay.
10. 阐明抗体-半抗原识别用于25-羟基维生素D3的即时免疫分析PMID:日期:2026-09-08Accurate quantification of 25-hydroxyvitamin D3 (25(OH)D3), the gold-standard biomarker for vitamin D nutritional assessment, still presents considerable analytical challenges. Although 25(OH)D3 exhibits intrinsic photosensitivity and thermal lability, these properties can be effectively managed via standardized light-shielding and inert-atmosphere operations. Key bottlenecks for its immunoassay lie in empirical-driven antibody screening lacking systematic theoretical guidance and poor discrimination of structurally similar vitamin D metabolites. To address these bottlenecks, we explored the molecular-recognition mechanism of high-affinity monoclonal antibody mAb-1F3 toward its hapten using molecular-docking and binding-pocket analysis. Four key amino-acid residues (PHE 52, PHE 91, TYR 32, ILE 100) within the antibody complementarity-determining region form a cooperative binding network for specific recognition of the steroid nucleus and C25-hydroxyl moiety of 25(OH)D3. π-alkyl interactions from PHE 52, PHE 91 and TYR 32 stabilize the hydrophobic steroid skeleton, while ILE 100 forms a conserved hydrogen bond (2.8 Å) to realize specific recognition of the C25-hydroxyl group. This structurally synergistic binding mechanism endows mAb-1F3 with high affinity (IC50 = 24.8 ng/mL) and favorable metabolite-discriminating capability. Guided by this mechanistic insight, recombinant mAb-1F3 was prepared and integrated into a rapid colloidal-gold lateral-flow immunoassay (LFIA). Standard matrix-specific sample extraction procedures were adopted to mitigate matrix interference induced by the high lipophilicity of 25(OH)D3 in complex samples. The LFIA completes the detection within 5 min and shows satisfactory linear consistency with LC-MS/MS in raw milk, dietary supplement, and human serum matrices. This work establishes a structure-driven strategy for rational antibody characterization and design, provides critical mechanistic support for conventional empirical antibody-screening workflows, and facilitates performance improvement of vitamin D immunoanalytical methods.