增强心磁图中的电流源成像:传感器阵列配置的影响
Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.
Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.
虽然心磁图(MCG)是一种用于评估心脏电生理的无创工具,但其传统的平面传感器阵列往往难以准确估计远离传感器的源。这一局限性阻碍了对深部心脏活动的精确定位。本研究旨在通过研究一种新型圆柱形传感器阵列来克服这一挑战,该阵列旨在提高源电流估计的准确性。我们结合数值模拟、体模测量和活体大鼠实验,将圆柱形传感器阵列与传统的平面阵列进行比较。在受控局灶源条件下,模拟和体模实验采用单偶极子定位,而对动物MCG数据则同时应用了单偶极子拟合和基于最小范数估计(MNE)的分布式源分析。模拟和体模测量表明,在传感器-源距离相当的条件下,圆柱形阵列实现的单偶极子定位比平面阵列更准确。在动物实验中,使用单偶极子拟合未能明显观察到这一优势。基于MNE的分布式源分析显示出几何形状依赖的重建模式,圆柱形阵列产生更偏后分布的活动和更高的源图可重复性。圆柱形传感器阵列为前部平面采样提供了互补的空间信息,特别是对于较深或偏后的心脏活动。这些发现表明,环绕式传感器覆盖可为基于MCG的重建提供互补信息,尽管仍需使用真实激活模型进行进一步验证。
While magnetocardiography (MCG) is a non-invasive tool for assessing cardiac electrophysiology, its conventional planar sensor array often struggles to accurately estimate sources distant from the sensor. This limitation hinders the precise localization of deep cardiac activity. This study aims to overcome this challenge by investigating a novel cylindrical sensor array designed to improve source current estimation accuracy. We combined numerical simulations, phantom measurements, and in vivo rat experiments to compare a cylindrical sensor array with a conventional planar array. Single dipole localization was used in the simulation and phantom experiments under controlled focal source conditions, whereas both single-dipole fitting and minimum norm estimation (MNE)-based distributed source analyses were applied to the animal MCG data. The simulations and phantom measurements showed that the cylindrical array achieved more accurate single-dipole localization than the planar array under comparable sensor-source distance conditions. In the animal experiments, this advantage was not clearly observed using single-dipole fitting. The MNE-based distributed source analysis showed geometry-dependent reconstruction patterns, with the cylindrical array producing more posteriorly distributed activity and higher source map repeatability. The cylindrical sensor array provided complementary spatial information to anterior planar sampling, particularly for deeper or posterior cardiac activity. These findings suggest that surrounding sensor coverage may provide complementary information for MCG-based reconstruction, although further validation with realistic activation models remains necessary.
Wenyu Shang, Motofumi Fushimi, Shinichi Chikaki, Masaki Sekino. Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.. Annals of biomedical engineering. 2026; doi:10.1007/s10439-026-04343-y.
Wenyu Shang, Motofumi Fushimi, Shinichi Chikaki, Masaki Sekino (2026). Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.. Annals of biomedical engineering. https://doi.org/10.1007/s10439-026-04343-y
Wenyu Shang, Motofumi Fushimi, Shinichi Chikaki, Masaki Sekino. Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.[J]. Annals of biomedical engineering, 2026 doi:10.1007/s10439-026-04343-y.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出