一种受终止剂启发的液态金属支架,用于治疗动脉粥样硬化性血管狭窄,具有精确的血管匹配和磁热调节的活性降解
A terminator-inspired liquid metal stent for treating atherosclerotic vascular stenosis with precise vascular matching and magnetothermally regulated active degradation.
A terminator-inspired liquid metal stent for treating atherosclerotic vascular stenosis with precise vascular matching and magnetothermally regulated active degradation.
动脉粥样硬化是心血管疾病的主要病理基础。血管支架植入作为治疗动脉粥样硬化的关键介入手段,目前面临缺乏个性化定制、难以与病变血管精准匹配以及血栓形成和再狭窄风险持续时间长等挑战。受电影中形状可变的液态金属机器人T-1000的启发,本研究率先将液态金属(LM)应用于血管介入治疗。将LM浇铸入模具,经钻孔和打磨制成Hep/PLL/PDA/LM支架。其肝素涂层赋予有效的抗血栓活性并减轻再狭窄。更重要的是,在血管重塑过程完成后,该支架可通过施加交变磁场实现无创降解。此外,该支架材料具有显著的抗氧化和抗炎特性。上述研究结果表明,LM的磁热特性使精准匹配病变血管并实现可控降解的血管介入治疗成为可能。这一能力可从根本上解决传统血管支架长期留存所带来的安全风险,并有望免除后续外科干预的必要性。
Atherosclerosis represents the primary pathological basis of cardiovascular diseases. Vascular stent implantation as a key intervention for treating atherosclerosis, currently faces challenges such as the lack of personalized customization, difficulty in precisely matching diseased vessels, and prolonged risks of thrombosis and restenosis. Inspired by the shape-shifting liquid-metal robot T-1000 from the film , this research pioneers the use of liquid metal (LM) in vascular interventional therapy. LM was cast into a mold, then drilled and ground to the Hep/PLL/PDA/LM stent. Its heparin coating confers effective anti-thrombogenic activity and mitigates restenosis. More importantly, after the process of vascular remodeling, the stent can be degraded non-invasively through the application of an alternating magnetic field. Furthermore, the stent material exhibits notable antioxidant and anti-inflammatory properties. The findings above suggest that the magnetothermal characteristics of LM make it possible to precisely match diseased vessels and achieve controllably degradable vascular interventional therapy. This capability can fundamentally address the safety risks associated with the prolonged presence of traditional vascular stents, potentially eliminating the necessity for follow-up surgical interventions.
Jianxiang Xiong, Li Huang, Jingzheng Huang, Zhibin Zhou, Shen Hu, Wenpeng Zhao, et al. A terminator-inspired liquid metal stent for treating atherosclerotic vascular stenosis with precise vascular matching and magnetothermally regulated active degradation.. Materials today. Bio. 2026; doi:10.1016/j.mtbio.2026.103561.
Jianxiang Xiong, Li Huang, Jingzheng Huang, Zhibin Zhou, Shen Hu, Wenpeng Zhao, et al (2026). A terminator-inspired liquid metal stent for treating atherosclerotic vascular stenosis with precise vascular matching and magnetothermally regulated active degradation.. Materials today. Bio. https://doi.org/10.1016/j.mtbio.2026.103561
Jianxiang Xiong, Li Huang, Jingzheng Huang, Zhibin Zhou, Shen Hu, Wenpeng Zhao, et al. A terminator-inspired liquid metal stent for treating atherosclerotic vascular stenosis with precise vascular matching and magnetothermally regulated active degradation.[J]. Materials today. Bio, 2026 doi:10.1016/j.mtbio.2026.103561.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出