在三级护理医院进行的11至14周扫描中,孕早期胎盘横波弹性成像对预测妊娠期高血压疾病的诊断性能

Diagnostic Performance of First-Trimester Placental Shear Wave Elastography for Predicting Hypertensive Disorders of Pregnancy During the 11- to 14-Week Scan in a Tertiary Care Hospital.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

引言 妊娠期高血压疾病(HDP)是孕产妇及围产儿发病的重要原因。尽管临床高血压通常在妊娠20周后才明显显现,但胎盘形成异常在更早时期即已开始。胎盘剪切波弹性成像(SWE)是一种定量超声技术,可测量组织硬度,可能有助于在临床疾病显现之前识别胎盘的早期生物力学改变。本研究评估了在11~14周超声检查时进行的胎盘SWE对预测后续发生HDP的关联性及诊断效能。方法 本项基于医院的前瞻性分析观察性研究在锡金甘托克锡金马尼帕尔医学研究所中央转诊医院放射诊断科进行。在知情同意后纳入接受常规早孕期颈项透明层及鼻骨(NTNB)超声检查的孕妇。使用迈瑞DC-80 X Insight超声系统(深圳迈瑞生物医疗电子股份有限公司,中国深圳)配备SC5-1E凸阵探头进行胎盘SWE检查。在胎盘实质内放置三个约5 mm的感兴趣区,避开胎盘边缘、脐带插入处、胎盘湖、局灶性不均匀区,并避免探头压力过大。采用EMAX、EMEAN和EMIN的平均值进行分析。在28、32、36周及40周或分娩时对孕妇进行随访。进行组间比较和受试者工作特征(ROC)曲线分析。结果 80名入组孕妇中,5名因失访或流产被排除。最终分析纳入75名孕妇。其中57名血压保持正常,18名发生HDP。HDP组包括7名妊娠期高血压(PIH)/妊娠期高血压疾病患者和11名子痫前期患者。未记录到子痫病例。HDP组EMAX平均值显著高于非HDP/血压正常组(13.09 ± 4.79 kPa vs 10.24 ± 4.02 kPa;p = 0.015)。EMEAN平均值亦显著升高(7.33 ± 2.88 kPa vs 5.93 ± 2.07 kPa;p = 0.027),而EMIN平均值未显示统计学显著差异(4.11 ± 1.62 kPa vs 3.47 ± 1.38 kPa;p = 0.105)。ROC分析显示,EMAX平均值诊断效能最佳,曲线下面积为0.682(95% CI:0.564-0.785;p = 0.009)。以>11.71 kPa为截断值,敏感度为61.1%,特异度为73.7%。EMEAN平均值曲线下面积为0.643(p = 0.058),EMIN平均值曲线下面积为0.607(p = 0.157)。结论 早孕期胎盘SWE在常规11~14周超声检查中可行。EMAX平均值对后续HDP的诊断效能最佳,EMEAN平均值显示显著的组间差异,但在ROC分析中未达到统计学显著性。总体诊断效能为中等。因此,胎盘SWE应被视为一种补充性影像生物标志物,而非HDP的独立筛查试验。

Abstract

Introduction Hypertensive disorders of pregnancy (HDP) are important causes of maternal and perinatal morbidity. Although clinical hypertension usually becomes evident after 20 weeks of gestation, abnormal placentation begins much earlier. Placental shear wave elastography (SWE) is a quantitative ultrasound technique that measures tissue stiffness and may help identify early biomechanical changes in the placenta before clinical disease becomes apparent. This study evaluated the association and diagnostic performance of placental SWE performed during the 11- to 14-week scan for predicting the later development of HDP. Methods This hospital-based prospective analytical observational study was conducted in the Department of Radiodiagnosis, Central Referral Hospital, Sikkim Manipal Institute of Medical Sciences, Gangtok, Sikkim. Pregnant women attending routine first-trimester nuchal translucency and nasal bone (NTNB) scans were enrolled after informed consent. Placental SWE was performed using a Mindray DC-80 X Insight ultrasound system (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China) with an SC5-1E curvilinear probe. Three approximately 5 mm regions of interest were placed within the placental parenchyma, avoiding placental margins, cord insertion, placental lakes, focal heterogeneity, and excessive probe pressure. Averaged EMAX, EMEAN, and EMIN values were used for analysis. Women were followed at 28, 32, and 36 weeks and at 40 weeks or delivery. Group comparison and receiver operating characteristic (ROC) curve analysis were performed. Results Of 80 enrolled women, five were excluded due to loss to follow-up or abortion. The final analysis included 75 women. Among these women, 57 remained normotensive, and 18 developed HDP. The HDP group included seven women with pregnancy-induced hypertension (PIH)/gestational hypertension and 11 with preeclampsia. No case of eclampsia was recorded. EMAX Average was significantly higher in the HDP group than in the non-HDP/normotensive group (13.09 ± 4.79 kPa vs 10.24 ± 4.02 kPa; p = 0.015). EMEAN Average was also significantly higher (7.33 ± 2.88 kPa vs 5.93 ± 2.07 kPa; p = 0.027), while EMIN Average did not show a statistically significant difference (4.11 ± 1.62 kPa vs 3.47 ± 1.38 kPa; p = 0.105). On ROC analysis, EMAX Average showed the best diagnostic performance, with an area under the curve of 0.682 (95% CI: 0.564-0.785; p = 0.009). At a cut-off value of >11.71 kPa, sensitivity was 61.1%, and specificity was 73.7%. EMEAN Average showed an area under the curve of 0.643 (p = 0.058), while EMIN Average showed an area under the curve of 0.607 (p = 0.157). Conclusion First-trimester placental SWE was feasible during the routine 11- to 14-week ultrasound scan. EMAX Average showed the best diagnostic performance for later HDP, while EMEAN Average showed a significant group difference but did not reach statistical significance on ROC analysis. Overall diagnostic performance was moderate. Placental SWE should therefore be considered a complementary imaging biomarker rather than a standalone screening test for HDP.

如何引用

AMA

Rewati R Pokhrel, Barun K Sharma, Pesona G Lucksom, Tsella Lachungpa, Abhinash Sharma, Neeraj Rai, et al. Diagnostic Performance of First-Trimester Placental Shear Wave Elastography for Predicting Hypertensive Disorders of Pregnancy During the 11- to 14-Week Scan in a Tertiary Care Hospital.. Cureus. 2026; doi:10.7759/cureus.113098.

APA

Rewati R Pokhrel, Barun K Sharma, Pesona G Lucksom, Tsella Lachungpa, Abhinash Sharma, Neeraj Rai, et al (2026). Diagnostic Performance of First-Trimester Placental Shear Wave Elastography for Predicting Hypertensive Disorders of Pregnancy During the 11- to 14-Week Scan in a Tertiary Care Hospital.. Cureus. https://doi.org/10.7759/cureus.113098

GB/T 7714

Rewati R Pokhrel, Barun K Sharma, Pesona G Lucksom, Tsella Lachungpa, Abhinash Sharma, Neeraj Rai, et al. Diagnostic Performance of First-Trimester Placental Shear Wave Elastography for Predicting Hypertensive Disorders of Pregnancy During the 11- to 14-Week Scan in a Tertiary Care Hospital.[J]. Cureus, 2026 doi:10.7759/cureus.113098.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Cureus 的其他文献