不同钻孔方案对骨密度测量钻检测的低密度骨初级稳定性的影响
Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.
Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.
术中骨评估对于实现种植体初期稳定性至关重要,尤其是在低密度骨位点。钻孔扭矩值(DTV)已被提出作为骨密度的指标,并可能有助于指导钻孔预备方案以改善初期稳定性。然而,DTV与初期稳定性之间的关系,尤其是生物骨中的组织学骨参数,仍不明确。本研究旨在阐明在生物松质骨中,通过DTV检测的低密度骨位点采用不同钻孔方案对初期稳定性的影响。使用从牛肋骨获取的松质骨块。采用专门设计的扭矩测量钻头进行术中骨密度评估。根据DTV选取对应于Misch D4和D5的低密度骨位点。使用常规或缩径钻孔方案植入牙种植体。记录DTV、植入扭矩值(ITV)和种植体稳定性商(ISQ)。进行组织学评估以评价种植体周围的骨面积分数(BAF)。两组的ITV均低于临床推荐的初期稳定性范围;然而,缩径组的ITV显著高于常规尺寸组。两组的DTV均与ITV呈正相关。DTV与ISQ之间的正相关仅在常规尺寸组中观察到,而ITV与ISQ在两组中均呈正相关。组织学分析显示两组间BAF无显著差异。BAF与DTV、ITV和ISQ呈正相关。DTV反映了低密度组织现有的骨量,并与初期稳定性相关。术中评估钻孔扭矩有助于选择合适的钻孔方案以实现初期稳定性。通过测量DTV进行骨密度评估可能为低密度种植位点的术中评估提供一种临床有用的方法。
Intraoperative bone assessment is critical for achieving primary implant stability, particularly at low-density bone sites. Drilling torque value (DTV) has been proposed as an indicator of bone density and may help guide drilling preparation protocols to improve primary stability. However, the relationship between DTV and primary stability, especially histological bone parameters in biological bone, remains unclear. This study aimed to clarify the influence of different drilling protocols for primary stability at low-density bone detected by DTVs in biological cancellous bones. Cancellous bone blocks obtained from bovine ribs were used. A specially designed torque measurement drill was used to assess bone density intraoperatively. Based on the DTVs, low-density bone sites corresponding to Misch D4 and D5 were selected. The dental Implants were placed using either a normal or undersized drilling protocol. The DTVs, insertion torque values (ITVs), and implant stability quotient (ISQ) were recorded. Histological evaluation was performed to assess the bone area fraction (BAF) around the implant. The ITVs were lower than the clinically recommended range for primary stability in both groups; however, they were significantly higher in the undersized group than in the normal-sized group. The DTVs positively correlated with the ITVs in both groups. A positive correlation between DTV and ISQ was observed only in the normal-sized group, whereas ITV was positively correlated with ISQ in both groups. Histological analysis revealed no significant difference in BAF between the two groups. BAF positively correlated with DTV, ITV, and ISQ. DTV reflects the existing bone volume of low-density tissue and is correlated with primary stability. Intraoperative assessment of drilling torque would facilitate the selection of appropriate drilling protocols to achieve primary stability. Bone density evaluation by measuring the DTV may provide a clinically useful method for the intraoperative evaluation at low-density implant sites.
Yusuke Morimoto, Reiko Kobatake, Kazuya Doi, Yoshifumi Oki, Kaien Wakamatsu, Tomoko Izumikawa, et al. Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.. Clinical and experimental dental research. 2026; doi:10.1002/cre2.70430.
Yusuke Morimoto, Reiko Kobatake, Kazuya Doi, Yoshifumi Oki, Kaien Wakamatsu, Tomoko Izumikawa, et al (2026). Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.. Clinical and experimental dental research. https://doi.org/10.1002/cre2.70430
Yusuke Morimoto, Reiko Kobatake, Kazuya Doi, Yoshifumi Oki, Kaien Wakamatsu, Tomoko Izumikawa, et al. Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.[J]. Clinical and experimental dental research, 2026 doi:10.1002/cre2.70430.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出