开发用于中红外发酵监测的化学计量学平台
Development of a chemometric platform for mid-infrared fermentation monitoring.
Development of a chemometric platform for mid-infrared fermentation monitoring.
工业生物工艺开发仍然严重依赖HPLC等离线分析手段,此类方法虽然准确,但速度缓慢,限制了实时决策。过程分析技术(PAT)能够克服这一障碍,其中中红外光谱(mIR)可提供快速、灵敏且经济的监测。然而,大多数应用依赖偏最小二乘法(PLS)等复杂化学计量学工具,限制了非专业人员的采用,也限制了对数据来源的系统性评估。在此,我们提出一个简化的平台,用于快速光谱分析和化学计量学模型构建,以监测连续大肠杆菌发酵过程中的葡萄糖消耗和柠康苹果酸生产。该工作流程整合了基线校正、最优波数区域选择以及溶质浓度与曲线下面积(AUC)的相关性分析,无需高级统计学专业知识即可直接生成模型。在纯溶液、合成混合物和发酵液中的比较评估表明,连续培养是最稳健的校准数据集。虽然基线/AUC方法的平均绝对误差(约0.65 g L⁻)略高于PLS,但其预测准确、易于使用且快速,与HPLC值一致。本研究展示了一个实用且用户友好的基于mIR的平台/方法学,降低了PAT实施的技术门槛,加速了工业连续生物过程中实时监测的采用。
Industrial bioprocess development still depends heavily on off-line analytics such as HPLC, which, while accurate, are slow and limit real-time decision-making. Process Analytical Technologies (PAT) can overcome this barrier, with mid-infrared spectroscopy (mIR) offering fast, sensitive, and cost-effective monitoring. Yet, most applications rely on complex chemometric tools such as Partial Least Squares (PLS), restricting adoption by non-specialists and limiting systematic evaluation of data sources. Here, we present a streamlined platform for rapid spectral analysis and chemometric model construction to monitor glucose consumption and citramalic acid production during continuous E. coli fermentations. The workflow integrates baseline correction, optimal wavenumber region selection, and correlation of solute concentrations with the area-under-the-curve (AUC), enabling straightforward model generation without advanced statistical expertise. Comparative evaluation across pure solutions, synthetic mixtures, and fermentation broths revealed continuous cultures as the most robust calibration dataset. While the baseline/AUC method showed slightly higher mean absolute error (~ 0.65 g L⁻) than PLS, it provided accurate, accessible, and fast predictions consistent with HPLC values. This study demonstrates a practical and user-friendly mIR-based platform/methodology that lowers technical barriers to PAT implementation, accelerating adoption of real-time monitoring in industrial continuous bioprocesses.
Mario A Torres-Acosta, Naresh Mohan, Yiheng Yang, James Allen, John M Ward, Gary J Lye. Development of a chemometric platform for mid-infrared fermentation monitoring.. Scientific reports. 2026; doi:10.1038/s41598-026-64638-x.
Mario A Torres-Acosta, Naresh Mohan, Yiheng Yang, James Allen, John M Ward, Gary J Lye (2026). Development of a chemometric platform for mid-infrared fermentation monitoring.. Scientific reports. https://doi.org/10.1038/s41598-026-64638-x
Mario A Torres-Acosta, Naresh Mohan, Yiheng Yang, James Allen, John M Ward, Gary J Lye. Development of a chemometric platform for mid-infrared fermentation monitoring.[J]. Scientific reports, 2026 doi:10.1038/s41598-026-64638-x.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出