超快光固化对生物活性和常规块状填充树脂复合材料的辐照表面转化率和聚合物网络质量的影响:体外研究

Effect of Ultra-Fast Light Curing on the Irradiated-Surface Degree of Conversion and Polymer-Network Quality of Bioactive and Conventional Bulk-Fill Resin Composites: An In Vitro Study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

超快速高辐照度固化可缩短曝光时间,但其对转化率和聚合物网络完整性的影响在不同大块填充树脂复合材料之间可能存在差异。本体外研究设计为一项材料层面的辐照表面聚合行为研究。研究评估了辐照表面的转化率和聚合物网络质量,同时有意排除了对4 mm大块增量固化深度或整体聚合情况的评估。制备Filtek One Bulk Fill、SDR Plus、Beautifil Bulk Flowable和Beautifil Bulk Restorative的80个圆盘试样(6 mm × 4 mm)(每种材料/每种方案n = 10),使用多波LED以1200 mW/cm²照射10 s或3000 mW/cm²照射3 s进行固化。转化率(DC)仅通过ATR-FTIR在辐照(顶部)表面测定。乙醇诱导软化(ES%,即24 h乙醇浸泡后辐照表面Knoop硬度下降)作为聚合物网络质量(交联密度)的逆向间接指标。数据采用双因素方差分析和Tukey检验进行分析(α = 0.05);DC与ES%的关系在单个试样水平(n = 80)采用Pearson相关性检验。超快速固化产生的合并DC(66.30 ± 10.06%)高于传统固化(59.37 ± 7.96%;< 0.001),但该效应具有材料依赖性:Filtek One Bulk Fill(< 0.001)和Beautifil Bulk Flowable(= 0.035)的DC显著升高,而SDR Plus或Beautifil Bulk Restorative则无显著变化。ES%主要受材料影响(< 0.001),受固化方案影响较小(= 0.009)。在试样水平(n = 80),DC与ES%呈弱但具有统计学显著性的负相关(r = -0.31,= 0.006)。在本研究条件下,超快速固化下的辐照表面聚合行为主要取决于复合材料的配方,这强调在优化牙科修复材料时需要同时评估转化效率和聚合物网络质量。由于转化率仅在辐照表面进行评估,这些发现描述的是辐照表面行为,并不能提供4 mm增量底部达到充分固化的证据。

Abstract

Ultra-fast high-irradiance curing shortens exposure time, but its effects on conversion and polymer-network integrity may vary among bulk-fill resin composites. This in vitro study was designed as a materials-level investigation of irradiated-surface polymerization behavior. It evaluated irradiated-surface degree of conversion and polymer-network quality while deliberately excluding assessment of depth of cure or polymerization throughout the 4 mm bulk increment. Eighty disk specimens (6 mm × 4 mm) of Filtek One Bulk Fill, SDR Plus, Beautifil Bulk Flowable, and Beautifil Bulk Restorative (n = 10/material/protocol) were cured with a polywave LED at 1200 mW/cm for 10 s or 3000 mW/cm for 3 s. Degree of conversion (DC) was measured by ATR-FTIR on the irradiated (top) surface only. Ethanol-induced softening (ES%, Knoop-hardness reduction at the irradiated surface after 24 h ethanol immersion) served as an inverse, indirect indicator of polymer-network quality (cross-link density). Data were analyzed by two-way ANOVA and Tukey tests (α = 0.05); the DC-ES% relationship was examined by Pearson correlation at the individual-specimen level (n = 80). Ultra-fast curing yielded higher pooled DC (66.30 ± 10.06%) than conventional curing (59.37 ± 7.96%; < 0.001), but the effect was material-dependent: DC increased significantly for Filtek One Bulk Fill ( < 0.001) and Beautifil Bulk Flowable ( = 0.035), but not for SDR Plus or Beautifil Bulk Restorative. ES% was influenced mainly by material ( < 0.001) and less by curing protocol ( = 0.009). At the specimen level (n = 80), DC and ES% showed a weak but statistically significant negative correlation (r = -0.31, = 0.006). Within the conditions of this study, irradiated-surface polymerization behavior under ultra-fast curing depended primarily on composite formulation, underscoring the need to evaluate both conversion efficiency and polymer-network quality when optimizing dental restorative materials. Because conversion was assessed only at the irradiated surface, these findings describe irradiated-surface behavior and do not provide evidence of adequate cure at the bottom of the 4 mm increment.

如何引用

AMA

Sarah Fahad Alsenani, Sultan Binalrimal. Effect of Ultra-Fast Light Curing on the Irradiated-Surface Degree of Conversion and Polymer-Network Quality of Bioactive and Conventional Bulk-Fill Resin Composites: An In Vitro Study.. Materials (Basel, Switzerland). 2026; doi:10.3390/ma19153323.

APA

Sarah Fahad Alsenani, Sultan Binalrimal (2026). Effect of Ultra-Fast Light Curing on the Irradiated-Surface Degree of Conversion and Polymer-Network Quality of Bioactive and Conventional Bulk-Fill Resin Composites: An In Vitro Study.. Materials (Basel, Switzerland). https://doi.org/10.3390/ma19153323

GB/T 7714

Sarah Fahad Alsenani, Sultan Binalrimal. Effect of Ultra-Fast Light Curing on the Irradiated-Surface Degree of Conversion and Polymer-Network Quality of Bioactive and Conventional Bulk-Fill Resin Composites: An In Vitro Study.[J]. Materials (Basel, Switzerland), 2026 doi:10.3390/ma19153323.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Materials (Basel, Switzerland) 的其他文献