F波矢量幅度预测心房颤动导管消融后的复发

F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

心房颤动(房颤)导管消融存在已知的快速性心律失常复发风险,但术前仍难以预测复发。本研究评估了房颤期间无创f波向量幅度(FVM)对消融术后复发的预测价值。本观察性研究连续纳入2017年1月至2022年12月在三菱京都医院接受首次房颤消融且具备房颤期间基线12导联心电图资料的604例患者。使用计算机卡尺手动测量10秒内的最大f波振幅(FWA),FVM定义为三维空间中心房除极的幅度,采用视觉转换的Kors准正交法计算。结局指标为术后90天空白期后心房快速性心律失常的复发。中位随访时间为5.4(3.9-7.1)年。在多变量分析中,低FVM(<0.18 mV)是复发的独立预测因素(风险比[HR]=1.56,95%置信区间[CI]=1.16-2.15,p<0.01),左心房扩大(≥45 mm)亦是独立预测因素(HR=1.46,95% CI=1.08-1.98,p=0.01)。首次消融后5年无复发率在同时具有低FVM和左心房扩大的患者中最低(53.9%),在两者均无的患者中最高(78.3%,p<0.001)。风险分层仅在非阵发性房颤患者中清晰可见(49.4% vs. 79.9%,p<0.001)。相比之下,V1导联FWA低于0.10 mV(定义为细小f波)与消融术后复发无关。无创FVM测量可对非阵发性房颤患者消融术后复发风险进行分层,但在阵发性房颤患者中未显示出预测价值。

Abstract

Catheter ablation for atrial fibrillation (AF) carries a known risk of tachyarrhythmia recurrence, but the recurrence is still difficult to predict before the procedure. This study assessed the value of noninvasive f-wave vector magnitude (FVM) during AF in predicting recurrence following ablation. This observational study included 604 consecutive patients who underwent initial AF ablation between January 2017 and December 2022 at Mitsubishi Kyoto Hospital, and whose baseline 12-lead electrocardiograms during AF were available. The maximal f-wave amplitude (FWA) over a 10-s period was measured manually using computerized calipers, and FVM was defined as the magnitude of atrial depolarization in three-dimensional space, calculated using the visually transformed Kors' quasi-orthogonal method. The outcome measure was the recurrence of atrial tachyarrhythmias after a 90-day post-procedural blanking period. The median follow-up was 5.4 (3.9-7.1) years. In multivariable analysis, low FVM (< 0.18 mV) was an independent predictor of recurrence (hazard ratio [HR] = 1.56, 95% confidence interval [CI] = 1.16-2.15, p < 0.01) as well as left atrial dilatation (≥ 45 mm) (HR = 1.46, 95% CI = 1.08-1.98, p = 0.01). The 5-year recurrence-free rate after initial ablation was lowest in patients with both low FVM and left atrial dilatation (53.9%), and highest in those with neither (78.3%, p < 0.001). The risk stratification was only clear in patients with non-paroxysmal AF (49.4% vs. 79.9%, p < 0.001). In contrast, FWA below 0.10 mV in lead V1, defined as a fine f-wave, was not associated with recurrence following ablation. Noninvasive FVM measurement stratified the risk of recurrence after AF ablation in patients with non-paroxysmal AF, but did not show predictive value in those with paroxysmal AF.

如何引用

AMA

Misaki Naka, Tetsuma Kawaji, Bingyuan Bao, Tomoya Kimura, Shun Hojo, Shintaro Matsuda, et al. F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2026; doi:10.1007/s10840-026-02416-5.

APA

Misaki Naka, Tetsuma Kawaji, Bingyuan Bao, Tomoya Kimura, Shun Hojo, Shintaro Matsuda, et al (2026). F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. https://doi.org/10.1007/s10840-026-02416-5

GB/T 7714

Misaki Naka, Tetsuma Kawaji, Bingyuan Bao, Tomoya Kimura, Shun Hojo, Shintaro Matsuda, et al. F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation.[J]. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026 doi:10.1007/s10840-026-02416-5.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 的其他文献