JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY介入心脏电生理学杂志
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY(英文缩写 J INTERV CARD ELECTR),ISSN 1383-875X,eISSN 1572-8595,中文译名:介入心脏电生理学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.759 | Q4 |
| 2022 | 1.800 | Q4 |
| 2023 | 2.100 | Q3 |
| 2024 | 2.600 | Q2 |
| 2025 | 2.700 | Q2 |
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY 最新收录文献
-
1. First Latin American retrospective registry of cardiac ablation in pediatric and congenital heart disease patients. A LAHRS registry.
1. 首个拉丁美洲儿童及先天性心脏病患者心脏消融的前瞻性注册研究。一项LAHRS注册研究PMID:期刊:日期:2026-09-29Catheter ablation has been proven as an effective and safe therapy for tachyarrhythmias in pediatric and congenital heart disease (CHD) patients. Although there are international registries on the use of catheter ablation in these populations, none of them include Latin American countries. To assess the clinical characteristics of pediatric and congenital heart disease patients undergoing catheter ablation procedures. Data obtained includes types of arrhythmias, techniques, success, complications and recurrence rates. A descriptive and analytical retrospective observational study was performed. A closed coded online form available for 6 months was used. All electrophysiologists who practice pediatric electrophysiology in Latin America and were identified in a previous LAHSR's survey were invited to participate through Latin American Heart Rhythm Society (LAHRS) electronic media ( https://lahrs.org/ ). Participation was not mandatory, it was not encouraged by any economic or material goods, and an informed consent for the use of the data was required. Consecutive electrophysiological catheter procedures were included in children under 18 years of age or patients with CHD, regardless age, between 2017 and 2021. Twenty physicians from 8 Latin American countries participated. A total of 1778 procedures were reported, 53% were male, mean age was 12.4 ± 5.1 years and 8.5% had congenital heart disease. An ablation was attempted in 87% of the patients, using a non-irrigated tip radiofrequency catheter in 68% of them, and a 3-D mapping system in 29%. Radiofrequency was the most commonly used energy source in 98% of the cases. The most frequent substrates were accessory pathways in 69.5% (61% were manifest), followed by AV nodal reentry in 16.5% and ectopic atrial tachycardia in 4%. Additionally, there were 3.8% atrial flutter, 3.8% ventricular tachycardias, 1.2% premature ventricular contractions. Ablation was considered acutely successful in 93% of the cases. Mean total procedural time was 92.1 ± 36.8 min and mean total fluoroscopy time was 16.3 ± 9.4 min. Complication rate was 1.8% and included complete AV block in 3 patients (0.2%). No deaths were reported. The recurrence rate was 8.5%. In this first exclusively pediatric and congenital heart disease retrospective registry of catheter ablation in Latin America, a high rate of success and low incidence of complications was observed. This is in concordance with previously reported registries from other latitudes, proving that ablation is an effective and safe therapy in this group of patients.
-
2. Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes.
2. 监护麻醉与全身麻醉在球囊篮式脉冲场消融治疗心房颤动中的比较:一项年龄匹配的手术时间与急性手术结局分析PMID:期刊:日期:2026-09-25General anesthesia (GA) has been the preferred sedation strategy for atrial fibrillation (AF) catheter ablation in the United States, in part because pulsed-field ablation (PFA) systems cause skeletal muscle stimulation and discomfort that can be poorly tolerated under lighter sedation. A recently introduced balloon-in-basket (BiB) PFA system (VOLT) has been reported to produce less muscle stimulation and pain, potentially allowing Monitored Anesthesia Care (MAC) instead of GA. Whether MAC offers procedural efficiency advantages without compromising ablation efficacy in this context has not been well characterized. To compare procedural timing, ablation efficacy, and safety between MAC and GA in patients undergoing BiB PFA (VOLT) for AF, using an age-matched design. We retrospectively analyzed 39 consecutive MAC cases and a pool of 83 GA cases undergoing VOLT BiB PFA from a two-site electrophysiology registry. Each MAC patient was matched 1:1 to the nearest age available GA patient yielding 39 age-matched controls. Six different time intervals were collected: total room time, pre-procedure setup time, core procedure time, post-procedure turnover time, transseptal-to-left atrial (LA) sheath-out (dwell) time, and ablation catheter dwell time. Total ablation lesions delivered, acute procedural success (isolation of all four pulmonary veins), and procedural complications were also compared. Group comparisons were then made. In addition, EP laboratory facility cost savings and scheduling opportunity cost associated with the observed difference in total room time, using published EP/procedural-suite per-minute cost estimates were also determined. Total room time (103.5 ± 20.0 vs. 126.2 ± 33.1 min; p = 0.0004), pre-procedure setup time (33.4 ± 10.0 vs. 50.3 ± 28.0 min; p = 0.0007), and post-procedure turnover time (14.8 ± 9.3 vs. 21.4 ± 8.3 min; p = 0.0030) were significantly shorter with MAC. Core procedure time (55.3 ± 20.5 vs. 55.3 ± 23.9 min), transseptal-to-LA-sheath-out time (34.2 ± 12.9 vs. 35.7 ± 18.5 min) did not differ significantly between groups (both p ≥ 0.62). Ablation catheter dwell time was modestly longer with MAC (27.7 ± 11.9 vs. 24.2 ± 15.5 min; p = 0.036). Total ablation lesions delivered (17.6 ± 5.1 vs. 18.8 ± 7.2, p = 0.68) and acute procedural success (39/39 [100%] vs. 39/39 [100%]) were similar between MAC and GA, with no procedural complications in either group. One MAC case (2.6%) was converted to general anesthesia interprocedurally for coughing attributed to airway secretions. Applying published EP/procedural-suite per-minute cost estimates ($29-$60/minute) to the observed 22.7-min reduction in total room time, MAC was associated with an estimated $658-$1,362 in facility cost savings per case, with potential opportunity cost benefit for additional case scheduling. In an age-matched cohort undergoing BiB PFA (VOLT) for AF, MAC was associated with shorter total room time, pre-procedure setup time, and post-procedure turnover time than GA, with no difference in ablation lesion delivery, acute success, or complications. Anesthesia related time savings with MAC appear concentrated in room logistics rather than the ablation procedure itself, with no detectable difference in acute procedural outcomes in this small cohort, supporting MAC as a reasonable alternative to GA for BiB PFA.
-
3. Preemptive mechanical circulatory support in ventricular tachycardia ablation: A systematic review and meta-analysis.
3. 室性心动过速消融中预先机械循环支持:系统综述与荟萃分析PMID:期刊:日期:2026-09-22The benefit of preemptive mechanical circulatory support (MCS) for ventricular tachycardia (VT) ablation remains unclear. This meta-analysis compared the efficacy and safety of preemptive MCS to standard care for VT ablation. An unrestricted literature search of PubMed, Embase, and Web of Science identified studies on preemptive MCS for VT ablation. MCS included percutaneous left ventricular assist devices or extracorporeal membrane oxygenation. The primary endpoint was all-cause mortality; secondary endpoints included VT recurrence, procedural time, procedural complications (vascular access, bleeding, stroke, pericardial effusion, heart failure, myocardial infarction), and 30-day major adverse cardiovascular events (MACE). Eight studies with 2,262 patients (414 with MCS, 1,848 without) were included. Mean follow-up was 15.8 months, mean age was 62.6 years, 12.5% were women, and mean PAINESD scores were 15.7 in the MCS group and 10.5 in the no-MCS group. There was no significant difference in all-cause mortality (OR 1.58, 95% CI 0.60-4.19, p = 0.36, I²=81%) or VT recurrence (OR 1.03, 95% CI 0.68-1.56, p = 0.90, I²=46%). Preemptive MCS was associated with longer procedural times (mean difference 46.0 min, 95% CI 11.1-80.8, p = 0.01, I²=86%), more procedural complications-driven by vascular access and pericardial effusion (OR 2.25, 95% CI 1.26-4.03, p = 0.006, I²=33%). Thirty-day MACE was not uniformly defined across studies and was therefore not pooled. Preemptive MCS was not associated with a significant difference in all-cause mortality or VT recurrence in patients undergoing VT ablation but was associated with longer procedures, and more procedural complications. The certainty of evidence was very low, reflecting the observational study design, baseline imbalance between groups, and heterogeneity; these findings do not preclude the selective use of MCS in high-risk patients and require confirmation in randomized trials.
-
4. Left ventricular ablation for ventricular tachycardia using a variable-loop circular pulsed field ablation catheter.
4. 使用可变环状圆形脉冲电场消融导管进行室性心动过速的左心室消融PMID:期刊:日期:2026-09-19Pulsed field ablation (PFA) has been increasingly used for ventricular ablation. We present a novel case describing use of a variable-loop circular PFA catheter (Varipulse, Biosense Webster, Inc., Irvine, CA, USA) via a retrograde aortic approach for left ventricular ventricular tachycardia ablation. Retrograde aortic access was achieved using a long sheath (Ventrax system, Merit Medical, South Jordan, UT) permitting safe unsheathing and manipulation of the variable-loop PFA catheter to avoid entrapment with the mitral valve apparatus. The procedure was completed without complication and no VT recurrence was observed over 3 months follow-up. This case highlights the feasibility of this approach and expands the potential applications of this integrated PFA platform beyond its current indication for atrial fibrillation ablation.
-
5. High-density mapping of his-ventricular intervals: impact of recording site and sex-specific differences.
5. 希氏-心室间期的高密度标测:记录部位的影响及性别特异性差异PMID:期刊:日期:2026-09-18Accurate assessment of the His-ventricular (HV) interval is essential to diagnosing infranodal conduction disease, but the influence of recording site and sex on HV values is not well defined. To evaluate the impact of measurement location and sex on HV interval values using high-density (HD) mapping catheters in patients undergoing atrial fibrillation (AF) ablation. We prospectively studied patients in sinus rhythm undergoing AF ablation. HV intervals were measured with a decapolar catheter and a HD mapping catheter at the end of the procedure. HD-based HV intervals were classified as proximal (HV), distal (HV), and right bundle (HV) recordings. Conduction velocities and sex-specific differences were analyzed. A total of 67 patients (mean age 64 ± 10 years, 33%women) were evaluated. The clinical HV interval was 45 ± 9 ms and shorter in women (40 ms vs. 47 ms, p < 0.001). HV was longer than HV (51 ± 10 ms vs. 46 ± 10 ms, p < 0.001) and HV (37 ± 10 ms; p < 0.001). Abnormal HV intervals (> 55 ms) were more often detected using HV than HV or HV. Conduction velocities did not differ by sex and correlated poorly with surface ECG parameters. HV interval measurements vary significantly by recording site and sex. Proximal measurements reveal longer HV intervals and detect more conduction delays, while women have systematically shorter HV intervals. Anatomical precision and sex-specific interpretation are important for accurate diagnosis of infranodal conduction delay.
-
6. First-in-human experience from RESET-AF (Rapid onE-Shot Electroporation Trial for Atrial Fibrillation).
6. RESET-AF(心房颤动快速单次电穿孔试验)的首次人体经验PMID:期刊:日期:2026-09-17Pulsed field ablation (PFA) is increasingly used to treat patients with atrial fibrillation (AF). The RESET-AF was a single-arm, first-in-human, clinical trial of AF ablation using a novel, single-shot PFA system (ElePulse, CRC EP, Tustin, CA, USA), trial registration ACTRN12622001523796 (Date registered 8th December 2022). In 36 consecutively-enrolled patients (57 ± 11 years, 69% male) with symptomatic paroxysmal (n = 22) and persistent (n = 14) AF, pulmonary vein isolation (PVI) was performed using this catheter, guided by 3D mapping. All patients underwent remapping at 3 months to confirm PVI durability. Patients were followed at 6 and 12 months with clinical review, Holter monitoring and electrocardiography. The primary efficacy and safety endpoints included a freedom from recurrent AF at 12 months > 50% and serious adverse events (SAE) at 7 and 30 days < 5%, respectively. The secondary efficacy endpoints included 3-month PVI durability > 50% and 6-month freedom from AF > 60%. All endpoints were achieved in the entire study cohort. There was 1 SAE (renal impairment which resolved with conservative management) with a total SAE rate of 2.8%. One patient was lost to follow-up at 12 months with a primary efficacy endpoint of 92% (32/35 patients). The secondary efficacy endpoints were 82% 3-month PVI and 94% (34/36 patients) 6-month freedom from AF. During the study, the PFA dose was adjusted in 3 cohorts. The "optimized subset" had 100% PVI durability and freedom from AF at 6 and 12 months without SAEs. This study of a novel PFA catheter system for ablation of paroxysmal and persistent AF achieved all predetermined primary and secondary clinical endpoints.
-
7. Comparative clinical outcomes of stylet-driven left bundle branch area pacing versus right ventricular pacing in patients with preserved ejection fraction: A 3-year follow-up study.
7. 保留射血分数患者中探针驱动左束支区域起搏与右心室起搏的比较临床结局:一项3年随访研究PMID:期刊:日期:2026-09-17Chronic right ventricular pacing (RVP) can exacerbate heart failure, but the clinical impact of left bundle branch area pacing (LBBAP) in patients with preserved left ventricular ejection fraction (LVEF) remains unclear. Because LBBAP has been performed almost exclusively with stylet-driven leads (SDLs) in Korea, we compared 3-year clinical outcomes between SDL-based LBBAP and conventional RVP in patients with preserved LVEF and a high anticipated pacing burden. This prospective registry enrolled de novo patients with preserved LVEF (≥ 50%) and an expected ventricular pacing burden > 20% who underwent transvenous permanent pacemaker implantation between 2020 and 2023. LBBAP was performed using stylet-driven leads (Tendril MRI, Abbott). The composite outcome comprised all-cause mortality, heart failure hospitalization (HHF), pacing-induced cardiomyopathy (PICM), and upgrade to biventricular pacing. Of 242 patients, 125 received RVP and 117 LBBAP. Clinical characteristics were comparable between groups, except that post-implant GLS was less impaired in the LBBAP group (-15.3 ± 3.6% vs. -17.6 ± 3.5%; p < 0.001). Paced QRS duration (pQRSd) was shorter with LBBAP (157.5 ± 17.7 ms vs. 129.1 ± 18.0 ms; p < 0.001). LBB capture was achieved in 103 patients (88.1%) and LVSP in 14 (11.9%). Over a median 3-year follow-up, the primary composite outcome occurred in 33 patients (26.4%) in the RVP group and 12 (10.3%) in the LBBAP group (p = 0.003), driven by HHF (7.2% vs. 0.9%; p = 0.016) and PICM (8.8% vs. 1.7%; p = 0.016); all-cause mortality did not differ significantly (16.0% vs. 8.5%; p = 0.096). In multivariable Cox analysis, early post-implant GLS (HR 1.361; 95% CI 1.009-1.834; p = 0.043) and pQRSd (HR 1.124; 95% CI 1.057-1.196; p < 0.001) were independently associated with PICM. In patients with preserved LVEF and a high pacing burden, LBBAP using stylet-driven leads was feasible and safe and was associated with better 3-year clinical outcomes than RVP, in parallel with a narrower paced QRS duration and better-preserved early post-implant GLS.
-
8. Persistent iatrogenic atrial septal defect after single-puncture, double transseptal access for 4D ICE-guided left atrial appendage occlusion: Incidence and clinical outcomes.
8. 单次穿刺双房间隔入路4D ICE引导下左心耳封堵术后持续性医源性房间隔缺损:发生率及临床结局PMID:期刊:日期:2026-09-16Persistent iatrogenic atrial septal defect (iASD) is a known consequence of transseptal puncture (TSP). Large-bore double transseptal access through a single TSP is commonly used for intracardiac echocardiography (ICE)-guided left atrial appendage occlusion (LAAO). This study evaluated the incidence and clinical outcomes of persistent iASD following this approach. We retrospectively reviewed LAAO procedures at a single academic center from January 2020 to December 2024. Cases were grouped as: (1) 4D ICE with double transseptal access (n = 58), (2) 2D ICE with double transseptal access (n = 64), or (3) no left atrial (LA) ICE (n = 81). Patients were included if they had follow-up imaging (TEE or cardiac CT). Multivariable logistic regression identified predictors of persistent iASD. Among 203 patients (age 77.1 ± 6.6 years; 59% male), follow-up occurred at 58.0 ± 25.2 days. Persistent iASD was detected in 88 patients (43%). ICE-guided cases had a higher incidence of iASD compared with no LA ICE (54.1% vs. 27.2%; p < 0.001), with no difference between 2D and 4D ICE (p = 0.340). On multivariable analysis, both 2D and 4D ICE were independently associated with increased odds of persistent iASD (2D ICE: OR 3.45, 95% CI 1.46-8.17; 4D ICE: OR 3.57, 95% CI 1.52-8.38). Coronary artery disease was associated with increased odds (OR 2.44, 95% CI 1.12-5.28), while hypertension was associated with decreased odds (OR 0.41, 95% CI 0.18-0.96). Persistent iASD was not associated with adverse clinical outcomes. Persistent iASD is common following LAAO, occurring in 43% of patients at early follow-up. Left atrial ICE use is independently associated with increased odds of persistent iASD, with similar rates between 2D and 4D ICE techniques.
-
10. Left atrial anatomy and atrial arrhythmia recurrence after pulsed-field ablation.
10. 脉冲场消融后左心房解剖结构与房性心律失常复发PMID:期刊:日期:2026-09-16The impact of left atrial (LA) anatomical features on atrial arrhythmia (AA) recurrence after pulsed-field (PF)-based pulmonary vein isolation (PVI) is unknown. This study aimed to assess LA anatomical features associated with long-term AA recurrence after PVI. We prospectively enrolled patients undergoing PVI with a pentaspline PF-catheter at a tertiary center from June 2023 to September 2024. AA recurrence was assessed at 3, 6 and 12 months with Holter-ECGs and symptom-driven monitoring. The following anatomical features were assessed in pre-interventional CT or MR imaging: pulmonary vein (PV) ostial diameters, circularity, cross-sectional area, and inter-carina distances. Regression models adjusted for established risk factors were used for their associations with AA recurrence. Among 287 patients (median age 66 years; 34% female; 61% paroxysmal AF), 98 (34%) experienced recurrence at a median of 6 months after PVI. In adjusted regression analysis, a larger minimal diameter of the right superior PV (OR 1.11 per 1 mm increase, 95% CI (1.02-1.21); p = 0.021), and higher circularity indices of the left inferior PV (OR 1.04 per 0.01 increase, 95% CI (1.01-1.07); p = 0.005) and the right superior PV (OR 1.03 per 0.01 increase, 95% CI (1.00-1.06); p = 0.040) were associated with AA recurrence. There was no interaction for catheter size but some effect modification for the number of PF-applications. Specific anatomical features of the right superior and left inferior PV were associated with recurrence after PF-based PVI. Although PF-based PVI appears suitable across diverse LA anatomies, the prognostic value of these anatomical characteristics warrants further investigation.