结合基于抗体的筛查方法,用于鉴定和定量工艺用水中的嗜肺军团菌

Combination of antibody-based screening methods for the identification and quantification of Legionella pneumophila in process water.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

军团病是一种严重且常致命的肺炎,主要由吸入被水源性病原体嗜肺军团菌血清群1型污染的气溶胶引起。尽管基于培养的传统检测通常是监测蒸发冷却系统的标准方法,但所需的10天培养期延迟了必要的风险评估。为克服这一时间障碍,我们将一种新方法应用于基于流式化学发光夹心微阵列免疫分析,使用冷冻保存的嗜肺军团菌标准品进行快速且不依赖培养的血清分型。该微阵列具有九种单克隆和一种多克隆捕获抗体,成功地在低至每100 mL 10个总细胞的浓度下表征了高毒力的Pontiac群,并在较低浓度下特异性鉴定了高传染性的Philadelphia亚型为Pontiac群的一个菌株。然而,直接亚分型仍存在一些局限性。为应对这一挑战,开发了一种将免疫磁分离和流式细胞术与化学发光夹心微阵列免疫分析相结合的新工作流程。由于流式细胞术定量后细胞活力得以保持,细胞可随后进行短暂培养,并可使用单菌落进行亚分型。与之前一样,我们使用冷冻保存的嗜肺军团菌标准品对含有四种不同亚型复杂混合物的真实工艺水样进行了加标。这种组合方法展示了诊断灵敏度,并成功缩短了总处理时间。该方法能够在真实且复杂的工艺水基质中,对嗜肺军团菌进行精确、早期的定量,并在达到和超过行动限值时进行详细的亚分型。

Abstract

Legionnaires' disease is a severe and often fatal pneumonia primarily caused by the inhalation of aerosols contaminated with the waterborne pathogen Legionella pneumophila serogroup 1. While conventional culture-based detection is often standard for monitoring evaporative cooling systems, the required 10-day cultivation period delays necessary risk assessments. To overcome this time barrier, we applied a novel approach to the flow-based chemiluminescence sandwich microarray immunoassay using cryopreserved Legionella pneumophila standards for rapid and culture-independent serotyping. The microarray features nine monoclonal and one polyclonal capture antibodies and successfully characterized the highly virulent Pontiac group at a concentration down to 10 total cells per 100 mL and specifically identified the highly infectious Philadelphia subtype at lower concentrations as a strain of the Pontiac group. However, some limitations of direct subtyping remain. To address the challenge, a novel workflow combining immunomagnetic separation and flow cytometry with the chemiluminescence sandwich microarray immunoassay was developed. Since viability is maintained after flow cytometric quantification, the cells can be subsequently cultured for a brief period, and single colonies can be used for subtyping. As before, we spiked real process water samples containing complex mixtures of four different subtypes using the cryopreserved Legionella pneumophila standards. This combined approach demonstrated diagnostic sensitivity, and successful reduction of the total processing time. The method enables both the precise, early quantification of Legionella pneumophila and detailed subtyping for demanded and exceeded action limits within real and complex process water matrices.

如何引用

AMA

Philipp Streich, Johannes Redwitz, Edith Harbich, Sandra Walser-Reichenbach, Caroline Herr, Markus Petzold, et al. Combination of antibody-based screening methods for the identification and quantification of Legionella pneumophila in process water.. Analytical and bioanalytical chemistry. 2026; doi:10.1007/s00216-026-06720-x.

APA

Philipp Streich, Johannes Redwitz, Edith Harbich, Sandra Walser-Reichenbach, Caroline Herr, Markus Petzold, et al (2026). Combination of antibody-based screening methods for the identification and quantification of Legionella pneumophila in process water.. Analytical and bioanalytical chemistry. https://doi.org/10.1007/s00216-026-06720-x

GB/T 7714

Philipp Streich, Johannes Redwitz, Edith Harbich, Sandra Walser-Reichenbach, Caroline Herr, Markus Petzold, et al. Combination of antibody-based screening methods for the identification and quantification of Legionella pneumophila in process water.[J]. Analytical and bioanalytical chemistry, 2026 doi:10.1007/s00216-026-06720-x.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Analytical and bioanalytical chemistry 的其他文献