使用液体接触式钙离子选择性电极对牙科树脂基复合材料钙释放的长期测量

Long-time measurements of calcium release by dental resin-based composites using a liquid-contact calcium ion-selective electrode.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

液接离子选择性电极在过去60年中已成功应用于电化学分析,并在现代分析化学中仍然是高度可靠的平台。由于其结构简单、制造成本低且操作行为可重现,只要充分理解其关键分析参数,这些传感器便为实时测量提供了一种有吸引力且稳健的替代方案。在本研究中,我们制备并表征了一种基于含有ETH-1001离子载体的商用膜鸡尾酒的微型钙离子选择性电极(micro-ISE)。我们系统评估了关键操作参数,以将该微电极定制用于局部传感,包括预期测量误差、背景电解质影响、信号稳定性、记忆效应和准确性。随后,将该微型传感器置于用于牙本质再矿化、具有不同无机组成的牙科复合样品(100% CaHPO/0%玻璃、50% CaHPO/50%玻璃和0% CaHPO/100%玻璃)上方20 μm处,以绘制在水溶液中浸泡最初2小时内的动态钙释放情况。传感器的准确度和精密度通过ICP-OES独立验证,证实了该micro-ISE适用于局部离子通量监测。

Abstract

Liquid-contact ion-selective electrodes have been successfully applied in electrochemical analysis over the past 60 years and remain a highly reliable platform in modern analytical chemistry. Owing to their structural simplicity, low fabrication cost, and reproducible operational behavior, these sensors offer an attractive and robust alternative for real-time measurements when their key analytical parameters are thoroughly understood. In this study, we fabricated and characterized a micro calcium ion-selective electrode (micro-ISE) based on a commercial membrane cocktail containing the ETH-1001 ionophore. Critical operational parameters were systematically evaluated to tailor the microelectrode for localized sensing, including expected measurement error, background electrolyte influence, signal stability, memory effects, and accuracy. The microsensor was subsequently positioned 20 μm above dental composite samples designed for dentin remineralization with varying inorganic compositions (100% CaHPO/0% glass, 50% CaHPO/50% glass, and 0% CaHPO/100% glass) to map dynamic calcium release over the first 2 h of immersion in an aqueous solution. Sensor accuracy and precision were independently validated by ICP-OES, confirming the micro-ISE's suitability for localized ion flux monitoring.

如何引用

AMA

Paula Calli Falcoswki, Bruna Marin Fronza, Handially Dos Santos Vilela, Roberto Ruggiero Braga, Mauro Bertotti. Long-time measurements of calcium release by dental resin-based composites using a liquid-contact calcium ion-selective electrode.. Analytical and bioanalytical chemistry. 2026; doi:10.1007/s00216-026-06810-w.

APA

Paula Calli Falcoswki, Bruna Marin Fronza, Handially Dos Santos Vilela, Roberto Ruggiero Braga, Mauro Bertotti (2026). Long-time measurements of calcium release by dental resin-based composites using a liquid-contact calcium ion-selective electrode.. Analytical and bioanalytical chemistry. https://doi.org/10.1007/s00216-026-06810-w

GB/T 7714

Paula Calli Falcoswki, Bruna Marin Fronza, Handially Dos Santos Vilela, Roberto Ruggiero Braga, Mauro Bertotti. Long-time measurements of calcium release by dental resin-based composites using a liquid-contact calcium ion-selective electrode.[J]. Analytical and bioanalytical chemistry, 2026 doi:10.1007/s00216-026-06810-w.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI