翻修全膝关节置换术中带套筒胫骨组件的无菌性失败:分区固定的新型放射学评估

Aseptic Failure of Tibial Components With Sleeves in Revision Total Knee Arthroplasty: A Novel Radiographic Assessment of Zonal Fixation.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

翻修全膝关节置换术(TKA)中无菌性袖套失败较为罕见,其相关危险因素仍知之甚少。现有评估柄填充度的方法存在不足。我们假设内侧基板支撑不足及柄尺寸偏小可导致带袖套胫骨组件的无菌性松动及内翻塌陷。本回顾性研究评估了2011年至2024年间在单一学术中心因胫骨袖套无菌性松动而接受翻修的TKA病例。采用Parsley法测量膝关节X线片上柄与骨内膜髓腔的填充比,填充充分定义为>0.85。使用ImageJ软件沿袖套及柄长度计算一种新的面积填充比,比较植入物面积与胫骨内总可用面积。内侧基板下方间隙>2 mm或骨水泥层过厚时,内侧基板支撑被视为“无支撑”。共有18例患者因带袖套胫骨组件无菌性松动接受翻修,其中大多数(55.6%)表现为内侧基板无支撑。采用传统Parsley法测得的骨干柄正位及侧位填充比偏小,分别为0.81 ± 0.13(平均值 ± 标准差)和0.77 ± 0.14。采用面积填充比法,正位及侧位骨干柄尺寸更为偏小,分别测得0.74 ± 0.1和0.68 ± 0.11。袖套正位及侧位面积填充比分别为0.55 ± 0.1和0.51 ± 0.07。内侧基板无支撑及胫骨柄尺寸偏小可能促进带袖套翻修TKA中的无菌性松动。现有柄填充度评估方法存在局限性,而柄及袖套面积填充比代表了一种全面测量植入物与骨内膜接触情况的新技术。

Abstract

Aseptic sleeve failure in revision total knee arthroplasty (TKA) is rare, and associated risk factors remain poorly understood. Shortcomings exist with current methods for assessing stem fill. We hypothesize that inadequate medial base plate support and undersized stems contribute to aseptic loosening and varus collapse of tibial components with sleeves. This retrospective review evaluated TKA cases revised for aseptic loosening of tibial sleeves at a single academic center from 2011 to 2024. Stem-to-endosteal canal fill ratios of knee radiographs were measured using the Parsley method, with adequate fill defined >0.85. A novel area fill ratio was calculated along the sleeve and stem length using ImageJ software comparing implant area to total available area within the tibia. Medial base plate support was considered "unsupported" with gapping underneath the base plate >2 mm or with an excessive cement mantle. Eighteen patients were revised for aseptic loosening of tibial components with sleeves, the majority (55.6%) demonstrating an unsupported medial base plate. Diaphyseal stem AP and lateral fill ratios using traditional Parsley method were undersized at 0.81 ± 0.13 (avg ± SD) and 0.77 ± 0.14, respectively. Using the area fill ratio method, the AP and lateral diaphyseal stems were more undersized measuring 0.74 ± 0.1 and 0.68 ± 0.11, respectively. Sleeve AP and lateral area fill ratios were 0.55 ± 0.1 and 0.51 ± 0.07. Unsupported medial base plates and undersized tibial stems may contribute to aseptic loosening in revision TKA with sleeves. Current stem fill assessments have limitations, whereas the stem and sleeve area fill ratio represents a novel technique for comprehensive measurement of implant-to-endosteal contact.

如何引用

AMA

Eric L Colomb, Trey C Rogers, Barrett B Torre, Alex R Orem, Michael B Sparks, Wayne E Moschetti. Aseptic Failure of Tibial Components With Sleeves in Revision Total Knee Arthroplasty: A Novel Radiographic Assessment of Zonal Fixation.. Arthroplasty today. 2026; doi:10.1016/j.artd.2026.102103.

APA

Eric L Colomb, Trey C Rogers, Barrett B Torre, Alex R Orem, Michael B Sparks, Wayne E Moschetti (2026). Aseptic Failure of Tibial Components With Sleeves in Revision Total Knee Arthroplasty: A Novel Radiographic Assessment of Zonal Fixation.. Arthroplasty today. https://doi.org/10.1016/j.artd.2026.102103

GB/T 7714

Eric L Colomb, Trey C Rogers, Barrett B Torre, Alex R Orem, Michael B Sparks, Wayne E Moschetti. Aseptic Failure of Tibial Components With Sleeves in Revision Total Knee Arthroplasty: A Novel Radiographic Assessment of Zonal Fixation.[J]. Arthroplasty today, 2026 doi:10.1016/j.artd.2026.102103.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Arthroplasty today 的其他文献