全膝关节置换术中聚乙烯厚度的精确性和准确性:传统测量切除和机器人辅助技术的比较
Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.
Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.
全膝关节置换术(TKA)旨在通过精确的骨切除和平衡的屈伸间隙来恢复原生膝关节运动学。聚乙烯厚度是决定关节线保留和稳定性的关键因素。本研究比较了机器人辅助(RA)和传统(C)TKA中聚乙烯植入物相对于术前计划的准确性和精确度。对2018年3月1日至2022年7月31日期间在同一机构由同一位外科医生实施TKA的所有患者进行了回顾性审查。患者被分类为接受RA-TKA或C-TKA。所有病例均计划使用9 mm聚乙烯厚度以实现平衡的屈伸间隙。记录患者人口学资料和最终聚乙烯厚度。比较了与计划厚度的平均差异、偏离计划的程度以及方差。共纳入815例患者,其中404例(49.6%)接受C-TKA,411例(50.4%)接受RA-TKA。两组间性别分布无差异,但RA-TKA组患者年龄显著更大(70.46 ± 8.52岁 vs 69.14 ± 8.34岁,= .027)。C-TKA组平均聚乙烯厚度大于RA-TKA组(10.67 mm ± 1.18 mm vs 9.34 mm ± 0.61 mm,< .001),平均差异分别为1.67 mm和0.34 mm。RA-TKA组对计划厚度的依从性更高(72.26% vs 16.09%),且方差显著更低(0.37 vs 1.39,< .001)。RA-TKA在实现计划聚乙烯厚度方面表现出更高的准确性和精确度,提示手术计划的执行得到改善且间隙平衡更加一致。前瞻性研究应确定这些差异是否能转化为更优的临床结局。
Total knee arthroplasty (TKA) aims to restore native knee kinematics through accurate bone resection and balanced flexion and extension gaps. Polyethylene thickness is a critical determinant of joint line preservation and stability. This study compared polyethylene implant accuracy and precision relative to the preoperative plan in robotic-assisted (RA) and conventional (C) TKA. A retrospective review was performed of all patients who underwent TKA by a single surgeon at a single institution between March 1, 2018, and July 31, 2022. Patients were classified as having undergone either RA-TKA or C-TKA. A 9-mm polyethylene thickness was planned in all cases to achieve balanced flexion and extension gaps. Patient demographics and final polyethylene thickness were recorded. Mean differences from the planned thickness, deviation from the plan, and variance were compared. A total of 815 patients were included, with 404 (49.6%) undergoing C-TKA and 411 (50.4%) undergoing RA-TKA. Sex distribution did not differ between groups, though patients in the RA-TKA group were significantly older (70.46 ± 8.52 years vs 69.14 ± 8.34 years, = .027). Mean polyethylene thickness was greater in C-TKA than RA-TKA (10.67 mm ± 1.18 mm vs 9.34 mm ± 0.61 mm, < .001) with mean differences of 1.67 mm and 0.34 mm, respectively. Adherence to the planned thickness was higher in RA-TKA (72.26% vs 16.09%) and variance was significantly lower (0.37 vs 1.39, < .001). RA-TKA demonstrated greater accuracy and precision in achieving planned polyethylene thickness, suggesting improved execution of the surgical plan and more consistent gap balancing. Prospective studies should determine whether these differences translate to superior clinical outcomes.
Kory B Dylan Pasko, McKenzie W Culler, Torie Oishi, Avinash Iyer, Nathanael D Heckmann, Andrew G Yun. Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.. Arthroplasty today. 2026; doi:10.1016/j.artd.2026.102097.
Kory B Dylan Pasko, McKenzie W Culler, Torie Oishi, Avinash Iyer, Nathanael D Heckmann, Andrew G Yun (2026). Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.. Arthroplasty today. https://doi.org/10.1016/j.artd.2026.102097
Kory B Dylan Pasko, McKenzie W Culler, Torie Oishi, Avinash Iyer, Nathanael D Heckmann, Andrew G Yun. Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.[J]. Arthroplasty today, 2026 doi:10.1016/j.artd.2026.102097.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出