一种基于聚散度的计算框架,用于优化环曲面补充型人工晶状体的旋转调整以最小化残余屈光性柱镜

A vergence-based calculation framework for optimal rotational adjustment of toric supplementary intraocular lenses to minimise residual refractive cylinder.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

提出一个透明、基于物理学且具有通用性的计算框架,用于预测复曲面补充性人工晶状体(SIOLs)的最佳旋转调整,包括植入有晶状体眼的复曲面有晶状体眼人工晶状体和植入人工晶状体眼的复曲面AddOn(次级睫状沟固定)晶状体,并量化四种角膜模型下预期的屈光获益。采用基于近轴聚散度的计算框架来预测未对准SIOL的最佳复曲面轴位。所需输入包括在眼镜平面测量的显性验光结果、角膜屈光力(使用薄角膜或厚角膜模型)、SIOL的标记等效屈光力和复曲面屈光力、测量的SIOL轴位以及SIOL轴向位置。有效晶状体位置通过将测量的后顶点位置与后顶点平面和像侧主平面之间的偏移量相结合来估算,该偏移量来源于既往有晶状体眼晶状体设计数据或定制模板SIOL模型。前向和后向球柱聚散度变换被嵌入非线性序列二次规划优化中,以确定使残余屈光性柱镜最小化的SIOL轴位。该方法在四种代表性临床场景中进行了演示,包括有晶状体眼、人工晶状体眼、角膜移植术后和既往激光视力矫正眼。在所有示例中,该模型预测了特定的SIOL旋转调整(16-18°),可显著降低屈光性柱镜。绝对降低范围为1.7至2.4 D,对应于67-94%的相对柱镜降低。该框架成功适应了不同的角膜模型和晶状体类型,并提供了预测的术后屈光度和定量性能指标。该框架能够跨多种角膜模型和晶状体几何形状对复曲面SIOL重新对准进行个体化规划。明确界定光学假设和聚散度变换,可使用常规临床输入可重复地预测最佳旋转和预期屈光获益。有必要进行前瞻性临床验证。

Abstract

To present a transparent, physics-based, and generalisable calculation framework to predict the optimal rotational adjustment of toric supplementary intraocular lenses (SIOLs), comprising toric phakic intraocular lenses implanted in the phakic eye and toric AddOn (secondary sulcus-fixated) lenses implanted in the pseudophakic eye, quantifying the expected refractive benefit across four corneal models. A paraxial vergence-based calculation framework was implemented to predict the optimal toric axis of a misaligned SIOL. Required inputs were the measured manifest refraction at spectacle plane, corneal power (using either thin- or thick-cornea models), labelled equivalent and toric power of the SIOL, measured SIOL axis, and axial SIOL position. The effective lens position was estimated by combining the measured back-vertex position with an offset between the back-vertex plane and the image-sided principal plane, derived from legacy phakic lens design data or custom template SIOL models. Forward and backward spherocylindrical vergence transformations were embedded in a nonlinear sequential quadratic programming optimisation to identify the SIOL axis that minimised residual refractive cylinder. The method was demonstrated in four representative clinical scenarios, including phakic, pseudophakic , keratoplasty, and prior laser vision correction eyes. In all examples, the model predicted a specific rotational adjustment of the SIOL (16-18°) that substantially reduced refractive cylinder. Absolute reductions ranged from 1.7 to 2.4 D, corresponding to relative cylinder reductions of 67-94%. The framework successfully accommodated different corneal models and lens types, and provided predicted postoperative refraction and quantitative performance metrics. This framework enables individualised planning of toric SIOL realignment across diverse corneal models and lens geometries. Explicitly defining optical assumptions and vergence transformations allows reproducible prediction of both optimal rotation and expected refractive benefit using routine clinical inputs. Prospective clinical validation is warranted.

如何引用

AMA

Achim Langenbucher, Nóra Szentmáry, Alan Cayless, Kamran M Riaz, Douglas D Koch, Jascha A Wendelstein. A vergence-based calculation framework for optimal rotational adjustment of toric supplementary intraocular lenses to minimise residual refractive cylinder.. Zeitschrift fur medizinische Physik. 2026; doi:10.1016/j.zemedi.2026.07.005.

APA

Achim Langenbucher, Nóra Szentmáry, Alan Cayless, Kamran M Riaz, Douglas D Koch, Jascha A Wendelstein (2026). A vergence-based calculation framework for optimal rotational adjustment of toric supplementary intraocular lenses to minimise residual refractive cylinder.. Zeitschrift fur medizinische Physik. https://doi.org/10.1016/j.zemedi.2026.07.005

GB/T 7714

Achim Langenbucher, Nóra Szentmáry, Alan Cayless, Kamran M Riaz, Douglas D Koch, Jascha A Wendelstein. A vergence-based calculation framework for optimal rotational adjustment of toric supplementary intraocular lenses to minimise residual refractive cylinder.[J]. Zeitschrift fur medizinische Physik, 2026 doi:10.1016/j.zemedi.2026.07.005.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Zeitschrift fur medizinische Physik 的其他文献