超高Dk Tisilfocon A角膜塑形镜的临床安全性和性能:一项前瞻性多中心研究

Clinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

这项前瞻性多中心研究评估了超高透氧率(Dk 180 ISO/Fatt)Tisilfocon A角膜塑形镜(Ortho-K)治疗近视的安全性和临床性能。研究纳入67名年龄8至49岁、近视度数最高达8.00 D的参与者,随访36周,评估裸眼视力(UCVA)、眼轴长度(AL)和角膜内皮细胞密度(ECD)。从第一周起,裸眼视力即显著改善,并持续稳定至第36周。眼轴长度总体延长具有统计学意义,主要由年轻参与者与年龄相符的生理性增长所驱动;成年人和高度近视个体未显示显著的眼轴延长。安全性评估显示生物相容性良好,未发生超过2级角膜染色的不良事件。佩戴镜片36周后角膜内皮细胞密度保持稳定,表明Tisilfocon A的超高透氧性有助于维持角膜健康并防止过夜佩戴期间的缺氧应激。总体而言,这些研究结果表明,超高透氧率Tisilfocon A角膜塑形镜是适用于多样化患者近视管理的安全有效的临床解决方案,可提供长期角膜完整性和稳定的视觉结局。在36周观察期内角膜内皮细胞密度保持稳定,提供了令人安心的短期至中期证据,表明Tisilfocon A的超高透氧性可能有助于限制过夜佩戴期间的缺氧应激。总体而言,这些研究结果表明,超高透氧率Tisilfocon A角膜塑形镜在该期间对多样化患者耐受性良好且临床有效;然而,由于缺乏同期对照组且随访时间相对较短,这些结果应视为初步结果,尚需更长期的对照研究来证实眼轴控制效果的持久性和角膜内皮安全性。

Abstract

This prospective multicenter study evaluated the safety and clinical performance of ultra-high Dk (180 ISO/Fatt) Tisilfocon A orthokeratology (Ortho-K) lenses to treat myopia. We enrolled 67 participants aged 8-49 years with myopia up to 8.00 D. Participants were followed for 36 weeks to assess uncorrected visual acuity (UCVA), axial length (AL), and corneal endothelial cell density (ECD). From the first week, UCVA significantly improved and remained stable through week 36. AL elongation was statistically significant overall, driven primarily by age-appropriate physiological growth in younger participants; adults and individuals with high myopia showed no significant axial elongation. Safety evaluations showed high biocompatibility with no adverse events exceeding Grade 2 corneal staining. ECD remained stable after 36 weeks of lens wear, demonstrating that the ultra-high oxygen permeability of Tisilfocon A supports corneal health and prevents hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are a safe and effective clinical solution for myopia management across diverse patients, providing long-term corneal integrity and stable visual outcomes. ECD remained stable over the 36-week observation period, providing reassuring short- to mid-term evidence that the ultra-high oxygen permeability of Tisilfocon A may help limit hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are well tolerated and clinically effective across diverse patients during this period; however, in the absence of a concurrent control group and given the relatively short follow-up, these results should be regarded as preliminary, and longer-term controlled studies are needed to confirm the durability of axial length control and corneal endothelial safety.

如何引用

AMA

Shang-Yen Wu, Jen-Hung Wang, Ti-Yen Cheng, Cheng-Jen Chiu. Clinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study.. Life (Basel, Switzerland). 2026; doi:10.3390/life16071143.

APA

Shang-Yen Wu, Jen-Hung Wang, Ti-Yen Cheng, Cheng-Jen Chiu (2026). Clinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study.. Life (Basel, Switzerland). https://doi.org/10.3390/life16071143

GB/T 7714

Shang-Yen Wu, Jen-Hung Wang, Ti-Yen Cheng, Cheng-Jen Chiu. Clinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study.[J]. Life (Basel, Switzerland), 2026 doi:10.3390/life16071143.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Life (Basel, Switzerland) 的其他文献