探讨两种不同市售动态对比增强磁共振成像(DCE-MRI)解决方案在前列腺癌(PCa)患者中所获得的灌注参数的一致性。本回顾性研究共纳入50例患者(平均年龄71.6岁;范围56-86岁),这些患者于2021年12月至2022年9月期间接受了根治性前列腺切除术。所有患者均在单台3T-MR扫描仪上接受了DCE-MRI检查。由两名放射科医师在参考定位图作为金标准进行影像-病理对照后,经协商一致在MR图像上完成肿瘤分割。随后,由两家不同厂商的专用市售解决方案计算四项灌注参数。两种解决方案均采用基于人群的动脉输入函数和扩展Tofts模型作为药代动力学模型。灌注参数如下:容积转运常数(K)、速率常数(k)、血管外细胞外间隙容积分数(v)和血浆容积分数(v)。采用Bland-Altman分析比较配对测量值之间的差异,并使用组内相关系数(ICC)评估可重复性。研究人群包括Gleason评分(GS)6分(=12例)、GS 7分(=34例)、GS 8分(=1例)和GS 9分(=3例)。所有参数均存在显著差异(<0.0001)。平均差异如下:K,-0.2102(95%置信区间:-0.2687至-0.1518);k,-0.7632(-0.9005至-0.6258);v,-0.1507(-0.2422至-0.05907);v,-0.02929(-0.03383至-0.02476)。平均测量的ICC如下:K,0.2989(-0.2355至0.6021);k,0.6883(0.4507至0.8231);v,-0.1331(-0.9967至0.3570);v,0.2653(-0.3106至0.5881)。两种解决方案之间的所有灌注参数均存在显著差异。因此,不建议跨不同解决方案比较灌注参数。

Abstract

: To investigate the agreement on perfusion parameters derived from two different commercially available solutions for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in patients with prostate cancer (PCa). A total of 50 patients (mean age, 71.6; range 56-86) who had undergone radical prostatectomy between December 2021 and September 2022 were included in this retrospective study. All patients had undergone DCE-MRI on a single 3T-MR scanner. Tumor segmentation on MR images was performed by two radiologists in consensus after radiologic-pathologic correlation using topographic maps as a reference standard. Subsequently, four perfusion parameters were calculated by dedicated commercially available solutions from two different vendors. Both solutions adopted a population-based arterial input function and an extended Tofts model as the pharmacokinetic model. The perfusion parameters were as follows; volume transfer constant (K), rate constant (k), volume fraction of extravascular extracellular space (v), and volume fraction of plasma (v). The differences between paired measurements were compared by Bland-Altman analyses and the reproducibility was evaluated using the intraclass correlation coefficient (ICC). : The study population consisted of Gleason score (GS) 6 ( = 12), GS 7 ( = 34), GS 8 ( = 1), and GS 9 ( = 3). Significant differences were found for all parameters ( < 0.0001). Mean differences were as follows: K, -0.2102 (95% confidence interval; -0.2687 to -0.1518); k, -0.7632 (-0.9005 to -0.6258); v, -0.1507 (-0.2422 to -0.05907); v, -0.02929 (-0.03383 to -0.02476). ICCs for average measures were as follows: K, 0.2989 (-0.2355 to 0.6021); k, 0.6883 (0.4507 to 0.8231); v, -0.1331 (-0.9967 to 0.3570); v, 0.2653 (-0.3106 to 0.5881). All perfusion parameters were significantly different between the two solutions. Therefore, comparison of perfusion parameters across different solutions is not recommended.

如何引用

AMA

Mingyu Kim, Seung Ho Kim, Joo Yeon Kim. Inter-Vendor Variability of Perfusion Parameters Derived from Dynamic Contrast-Enhanced MRI in Patients with Prostate Cancer.. Tomography (Ann Arbor, Mich.). 2026; doi:10.3390/tomography12070091.

APA

Mingyu Kim, Seung Ho Kim, Joo Yeon Kim (2026). Inter-Vendor Variability of Perfusion Parameters Derived from Dynamic Contrast-Enhanced MRI in Patients with Prostate Cancer.. Tomography (Ann Arbor, Mich.). https://doi.org/10.3390/tomography12070091