Tomography断层成像
Tomography(英文缩写 TOMOGRAPHY),ISSN 2379-1381,eISSN 2379-139X,中文译名:断层成像 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.000 | Q3 |
| 2022 | 1.900 | Q3 |
| 2023 | 2.200 | Q2 |
| 2024 | 2.200 | Q2 |
| 2025 | 2.500 | Q2 |
Tomography 最新收录文献
-
1. CardioSynergyNet: A Closed-Loop Multi-Task Deep Learning Architecture for Cardiac Segmentation and Biomarkers with Diagnosis from Paired ED-ES Cine-MRI.
PMID:日期:2026-09-21Cardiac MRI analysis typically treats segmentation, biomarker estimation, and disease classification as separate problems, even though clinical biomarkers are themselves derived from segmentation masks and diagnosis depends on both. This paper investigates whether a single jointly trained network can perform all three tasks without sacrificing accuracy on any of them. I propose CardioSynergyNet, which is a multi-task network with a weight-shared encoder for end-diastolic (ED) and end-systolic (ES) frames. Three modules link the tasks: Cross-Phase Deformation Attention (CPDA) models ED-ES deformation, a Differentiable Biomarker Extraction Layer (DBEL) computes eight clinical biomarkers directly from the soft segmentation mask, and Class-Conditional Prototype Feedback (CCPF) conditions segmentation on the predicted disease class. The model was trained and tested on 150 patients (30 per class across five diagnostic groups), who were split patient-wise into 110/20/20 train/validation/test, yielding 1489 paired ED/ES slices. On the test set, the model achieved a mean ED Dice score of 0.905 (computed across all four classes, including background), with the right ventricle being the hardest structure, particularly at ES. Biomarker regression was accurate for area- and mass-based quantities (R > 0.92) but weaker for ratio-based biomarkers such as ejection fraction (R = 0.66). Disease classification reached 76.65% accuracy with most confusions occurring between clinically similar disease pairs. The joint training of segmentation, biomarker extraction, and classification achieves performance competitive with task-specific models while keeping outputs across tasks consistent with one another, supporting cross-task feedback as a viable direction for integrated cardiac MRI analysis.
-
2. Routine Immediate Postoperative Chest Radiography After Minimally Invasive Pulmonary Lobectomy Has a Low Impact on Clinical Management: A Value-Based Imaging Analysis.
PMID:日期:2026-09-17Despite the widespread adoption of minimally invasive video-assisted thoracoscopic surgery (VATS) for pulmonary lobectomy and Enhanced Recovery After Surgery (ERAS) protocols, routine chest X-rays (CXRs) in the Post-Anesthesia Care Unit (PACU) after VATS pulmonary lobectomy remain common. Evidence questioning their clinical utility in asymptomatic patients is growing. This study aimed to evaluate the therapeutic yield of routine PACU CXRs following VATS lobectomy, in a homogeneous cohort (PACU time point). This single-center retrospective cohort study included 554 consecutive patients who underwent elective VATS lobectomy (2014-2025). The primary endpoint was the therapeutic yield of routine PACU CXRs, defined as the proportion directly leading to a documented change in postoperative management. Secondary outcomes included the yield of post-drain-removal CXRs, radiographic findings, and the yield in patients with intraoperative complications. Among 554 routine PACU CXRs, only 12 (2.2%; 95% CI: 1.1-3.7) led to a management change; surgical re-intervention was required in 1 patient and chest tube reinsertion in 5 patients. By contrast, 93 post-drain-removal CXRs (16.8%; 95% CI: 13.7-20.0) led to a change ( < 0.001). The most frequent abnormal findings were pneumothorax (5.8%), atelectasis (4.5%), and pleural effusion (2.0%). Routine PACU imaging generated an estimated cost of €16.620 and a cumulative radiation exposure of 27.7 mSv. Routine PACU CXR after VATS lobectomy has a very low therapeutic yield and rarely changes management in asymptomatic patients. These findings support a selective, symptom-driven imaging strategy, although further prospective studies are needed to confirm safety and effectiveness.
-
3. Association Between Cigarette Smoking and Carotid Plaque Stiffness Assessed Using Ultrasound Shear-Wave Elastography.
PMID:日期:2026-09-16Cigarette smoking alters carotid plaque composition. Two-dimensional ultrasound shear-wave elastography (2D-SWE) is a promising non-invasive imaging technique for quantifying plaque stiffness. This prospective study aimed to determine whether carotid plaque stiffness assessed using 2D-SWE is associated with smoking status. A total of 132 carotid plaques were evaluated from 93 patients who underwent carotid ultrasound 2D-SWE. Demographic and clinical data were collected, and patients were classified as current cigarette smokers (n = 45) and non-smokers (n = 48). A total of 65 carotid plaques in smokers and 67 in non-smokers were evaluated. Plaque stiffness was quantified using shear-wave velocity (m/s), with three SWE measurements obtained from each plaque. Demographic and clinical characteristics and plaque stiffness were compared according to smoking status, and correlations between smoking status and plaque stiffness were evaluated. A total of 396 SWE measurements were obtained from 132 carotid plaques (195 in cigarette smokers and 201 in non-smokers). Plaques in smokers demonstrated significantly greater stiffness than those in non-smokers, as indicated by shear-wave velocity (smokers: median 4.17 m/s, interquartile range (IQR) 1.94 vs. non-smokers: median 2.91 m/s, IQR 1.81, Z = -5.36, < 0.001). Smoking was positively correlated with shear-wave velocity (r = 0.27, < 0.001). No significant differences were observed between smokers and non-smokers in age, sex, hypertension, or diabetes mellitus. Cigarette smoking was associated with increased carotid plaque stiffness measured using ultrasound 2D-SWE. These findings suggest that SWE may provide a quantitative imaging marker of smoking-related differences in carotid plaque composition. Larger studies incorporating smoking duration and cumulative exposure are warranted to determine their clinical significance.
-
4. Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization.
PMID:日期:2026-09-15To evaluate the clinical feasibility, safety, and geometric characteristics of a supine CT-guided posterior approach using a custom dorsal-space mat in patients for whom the supine position was required or preferred. This retrospective study included 16 consecutive patients prepared for the approach. Puncture trajectory parameters, positional stability, technical success, procedure time, and adverse events were evaluated in successfully positioned patients ( = 15; 35 trajectories). A geometric model was constructed to estimate maximum allowable puncture angles determined by mat height, needle length, and table geometry. Positioning feasibility was 15/16 (93.8%); one patient was converted to a lateral approach due to shoulder pain. Technical success was 100% per patient (15/15) and per trajectory (35/35). The mean puncture angle and depth were 40.2° ± 9.1° and 8.3 ± 2.5 cm, respectively. All puncture angles were within theoretical geometric limits, with a mean angular margin of 14.9° ± 10.9°. Quantitative stability assessment was feasible in 14 patients; median two-dimensional displacement and absolute axial rotation were 4.1 mm (IQR, 3.3-4.5 mm) and 0.9° (IQR, 0.3-1.2°), respectively. Between-group differences observed in the trajectory-level analysis were not statistically significant in the patient-level sensitivity analysis. One Grade 5 adverse event occurred after RFA; although a relationship with the procedure could not be excluded, it was unrelated to the mat or puncture trajectory. This preliminary feasibility study suggests that the dorsal-space mat can provide sufficient working space for CT-guided posterior procedures while maintaining the supine position. Larger prospective studies are required to establish its broader clinical applicability and safety.
-
5. Hepatocellular Carcinoma Segmentation on MRI: Five-Fold ATLAS Benchmarking, Phase-Wise External Stress Testing, and Multiphasic OpenSwissHCC Ablation.
PMID:日期:2026-09-15To establish an auditable nnU-Net v2 HCC MRI segmentation benchmark, quantify phase- and cohort-dependent transportability without external fine-tuning, evaluate false-positive safety on HCC-negative examinations, and test whether complementary arterial-plus-venous input improves performance in OpenSwissHCC. A 3D full-resolution nnU-Net was trained by five-fold cross-validation on 60 public ATLAS cases. The unchanged five-fold ensemble was applied separately to arterial, portal/venous, delayed and native T1-weighted images in LiverHccSeg and OpenSwissHCC. All 132 OpenSwissHCC subjects (63 HCC-positive and 69 HCC-negative) underwent inference in every phase; positive-case overlap and detection were reported separately from negative-examination specificity. A patient-paired five-fold ablation compared venous-only with arterial-plus-venous OpenSwissHCC training. MRI-to-CT application to 97 valid-reference HCC-TACE-Seg cases was exploratory. The ATLAS out-of-fold mean Dice was 0.5315 (95% CI 0.4478-0.6126). The OpenSwissHCC positive mean Dice was 0.3388 arterial, 0.1267 venous, 0.1810 delayed and 0.0814 native; the corresponding detection was 55.6%, 28.1%, 27.6% and 23.8%, while the negative-examination specificity ranged from 50.7% to 81.2%. The detection was lower when all of the documented HCCs were <20 mm. Arterial-plus-venous training increased the mean Dice from 0.2269 to 0.3705 (paired difference +0.1435, 95% CI +0.0520 to +0.2343; = 0.00223) and reduced the false-positive voxel burden ( = 0.0394), although the binary detection increase was not significant by exact McNemar testing ( = 0.0639). The MRI-to-CT mean Dice was 0.0286. The HCC segmentation performance was strongly domain-sensitive. Multiphasic input improved segmentation quality within the cohort, but reliable clinical use requires substantially broader development and prospective validation.
-
6. Multimodal Characterization of Atrial Fibrillation: From Patient-Specific Anatomy and Electrophysiology to Standardized Atrial Mapping.
6. 心房颤动的多模态特征描述:从患者特异性解剖与电生理到标准化心房标测PMID:日期:2026-09-14This narrative review synthesizes a comprehensive multimodal characterization framework for atrial fibrillation (AF), tracing its progression from patient-specific anatomical reconstruction to electrophysiological phenotyping and standardized spatial mapping. The literature was identified through searches of PubMed, Web of Science, and Google Scholar, covering publications from January 2010 to June 2026, with additional studies identified from relevant references. Anatomical characterization leverages clinical imaging modalities alongside advanced deep learning models to execute precise whole-chamber, subregional, and tissue-level modeling. Electrophysiological profiling spans multi-scale modalities, including 12-lead electrocardiography (ECG), body surface potential mapping (BSPM), electrocardiographic imaging (ECGI), and electroanatomical mapping (EAM), complemented by wearable sensors for longitudinal rhythm surveillance. To bridge heterogeneous datasets across subjects and modalities, standardized coordinate systems and multimodal registration enable reproducible data integration. These integrated data parameterize patient-specific computational models to advance mechanistic insight, risk stratification, and personalized AF management. However, broad clinical translation remains constrained by imaging variability, reconstruction noise, registration uncertainty, and limited prospective multicenter validation. Future progress hinges on moving beyond technical accuracy toward prospective trials evaluating algorithm-guided clinical utility.
-
7. The Role of Interventional Radiology in the Diagnosis and Treatment of Gynecological Conditions.
7. 介入放射学在妇科疾病诊断与治疗中的作用PMID:日期:2026-09-11Interventional radiology (IR) has reshaped contemporary management strategies for selected gynecological and obstetric disorders by introducing minimally invasive, organ-sparing therapeutic alternatives to conventional surgical approaches. This review examines the current applications of IR in the treatment of symptomatic uterine fibroids, pelvic congestion syndrome, placenta accreta spectrum, cesarean scar pregnancy, and selected gynecological malignancies requiring palliative or preoperative embolization. In addition, selected vascular conditions in pregnancy, including visceral and cerebral aneurysms, are discussed due to their high-risk clinical profile and growing relevance for endovascular management. These entities were chosen because of their substantial clinical relevance, risk of severe complications, and the expanding body of evidence supporting endovascular management. Techniques such as uterine artery embolization and ovarian vein embolization are associated with high technical success and meaningful symptom reduction, while simultaneously decreasing hospitalization time, perioperative morbidity, and convalescence compared with traditional surgery. In complex obstetric scenarios-including placenta accreta spectrum and splenic artery aneurysm-prophylactic balloon occlusion and endovascular embolization may significantly limit life-threatening hemorrhage and improve maternal prognosis in appropriately selected patients when implemented within a multidisciplinary setting; for splenic artery aneurysm in particular, this evidence currently derives from case reports and small case series rather than comparative trials. Imaging modalities, including ultrasonography, computed tomography, magnetic resonance imaging, and angiography, are integral to diagnosis, patient qualification, procedural planning, and post-intervention monitoring. Although existing data generally confirm the safety and efficacy of interventional techniques, important limitations persist, including heterogeneous study populations, relatively small cohorts, and insufficient long-term reproductive follow-up. Greater standardization of clinical indications and procedural protocols, ongoing technological advancement, and well-designed multicenter trials are required to consolidate the evidence base. In gynecologic oncology, embolization techniques may provide effective hemorrhage control and facilitate surgical treatment in selected patients. In addition, uterine artery embolization has emerged as an important uterus-preserving adjunct in the management of cesarean scar pregnancy, although long-term reproductive (fertility) outcome data remain limited. IR is becoming an increasingly important component of modern gynecological care, supporting individualized, uterus-preserving, and less invasive therapeutic strategies; fertility preservation specifically is an important goal that, for several of the indications discussed, remains incompletely proven by long-term reproductive-outcome data.
-
8. MSF-Swin-ICFNet: An Image-Derived Multi-Scale Swin Transformer Framework with Cross-Scale Feature Fusion for Breast Lesion Classification and Segmentation in Mammograms.
PMID:日期:2026-09-10: Accurate breast lesion classification and localization from mammograms remain challenging because lesions vary in size, morphology, density, contrast, and boundary clarity. This study proposes MSF-Swin-ICFNet, an image-derived Multi-Scale Swin Transformer framework with Image-Derived Cross-Scale Fusion (ICF) for joint benign-malignant classification and lightweight lesion localization. : The proposed framework extracts hierarchical representations from four Swin Transformer stages and aligns, adaptively recalibrates, and fuses these multi-scale features into a shared representation for classification and lesion-mask prediction. The model was evaluated on CBIS-DDSM, comprising 891 patients and 1592 mammograms, and RTM, comprising 573 patients and 10,070 mammograms. Patient-level stratified partitioning was used to ensure that mammograms and associated annotations from the same patient remained within a single data partition. Classification was evaluated using accuracy, precision, recall, F1-score, and AUC-ROC, while lesion localization was assessed using the Dice coefficient. : MSF-Swin-ICFNet achieved strong mammogram-level classification performance on the patient-disjoint test cohorts. On CBIS-DDSM, the model achieved 0.949 accuracy, 0.931 F1-score, and 0.985 AUC-ROC. On RTM, it achieved 0.968 accuracy, 0.956 F1-score, and 0.992 AUC-ROC. The corresponding Dice coefficients for lesion localization were 0.786 on CBIS-DDSM and 0.878 on RTM. Ablation experiments further supported the contribution of cross-scale fusion, scale recalibration, feature refinement, and the boundary-aware localization head. : MSF-Swin-ICFNet demonstrates promising retrospective performance for image-based breast lesion classification with complementary lesion localization. The results support the technical potential of adaptive hierarchical feature fusion for mammographic analysis. However, the model is not intended as a standalone diagnostic system, and independent multicentre validation and radiologist reader studies are required before clinical deployment.
-
9. Symmetric Siamese Networks for Longitudinal Chest Radiograph Change Detection: A Leakage-Controlled Study on MIMIC-CXR.
PMID:日期:2026-09-09Radiologists usually read a chest radiograph by comparing it with an earlier one, yet most deep learning models are trained and tested on single images. This study measures how much a longitudinal pair of radiographs improves finding-specific change detection on MIMIC-CXR and tests whether the gain can be explained by encoder pretraining. One frontal pair per patient was built from the earliest and latest studies within 180 days (14,043 pairs), and paired CheXpert labels defined four transition classes: absent-to-absent, onset, resolved, and persistent. A Siamese DenseNet-121 with two symmetric, weight-sharing branches fused the two images through concatenation and feature difference, and it was compared with a matched baseline that received only the final image. Evaluation used patient-grouped five-fold cross-validation over five seeds and three leakage-free encoder regimes. On two matched binary tasks that hold the final image fixed-resolved versus absent (1→0 vs. 0→0) and onset versus persistent (0→1 vs. 1→1)-the single-image baseline performed at chance (AUROC 0.45 to 0.60), while the paired model scored well above it (paired difference +0.18 to +0.37 for resolution and +0.12 to +0.34 for onset; all significant by patient-level bootstrap after multiple-comparison correction), reaching a resolved-versus-absent AUROC of up to 0.87 (support devices). The benefit was stable across seeds, encoder regimes, projection changes, and follow-up intervals, and the CheXpert-derived transitions agreed with radiologist annotations (Cohen's κ up to 0.97). A prior radiograph adds value whenever the final image alone underdetermines the transition, and they support pair-based designs for longitudinal change analysis.
-
10. Cardiac Magnetic Resonance Findings and NT-proBNP in Heart Failure with Reduced Ejection Fraction.
10. 射血分数降低型心力衰竭的心脏磁共振表现与NT-proBNPPMID:日期:2026-09-08: N-terminal pro-B-type natriuretic peptide (NT-proBNP) is an established heart failure biomarker, but its associations with cardiac magnetic resonance (CMR) parameters in patients with reduced ejection fraction remain unclear. This study examined the associations between serum NT-proBNP concentrations and CMR-derived functional, structural, and tissue characterization parameters in patients with HFrEF and evaluated which imaging parameters remained associated with NT-proBNP after multivariable adjustment. : This retrospective single-center study included 92 consecutive patients with HFrEF who underwent CMR and NT-proBNP measurement within a 24 h window, with a median absolute interval of 6 h (range, 1-15 h) between the two assessments. CMR analysis included left ventricular ejection fraction (LVEF), left ventricular and left atrial (LA) cavity diameters, myocardial mass, extracellular volume fraction (ECV), the late gadolinium enhancement (LGE) burden, and the T2 signal intensity (T2-SI) ratio. Spearman correlation, univariate linear regression, and multivariable linear regression analyses were performed using log-transformed NT-proBNP values. : Log NT-proBNP demonstrated significant correlations with LVEF (r = -0.359, < 0.001), T2-SI ratio (r = -0.332, = 0.001), ECV (r = 0.383, < 0.001), and LA diameter (r = 0.347, < 0.001). No statistically significant correlations were observed between log-transformed NT-proBNP and LGE burden, LV cavity diameter, myocardial mass, LV wall thickness, age, or the recorded comorbidities. In multivariable analysis, LVEF, T2-SI ratio, and LA diameter remained associated with NT-proBNP after adjustment for the available covariates. : Lower LVEF, a lower T2-SI ratio, and a larger LA diameter were associated with higher NT-proBNP levels in patients with HFrEF. The T2-SI ratio and LA diameter should be considered exploratory imaging markers requiring prospective validation.