基于眶部MRI的突眼测量可靠性:一项多中心前瞻性研究
Reliability of Orbital MRI-Based Proptosis Measurement: A Multicenter Prospective Study.
Reliability of Orbital MRI-Based Proptosis Measurement: A Multicenter Prospective Study.
准确测量眼球突出度变化对于甲状腺相关眼病(TAO)的管理至关重要,然而传统Hertel眼球突出计存在观察者间不一致的问题。本研究旨在探讨基于磁共振成像(MRI)的眼球突出度测量的有效性,并开发一种自动化工具以提高诊断的可重复性。我们回顾性分析了2023年12月至2025年6月期间在中心1前瞻性入组的250例TAO患者的数据。由三名放射科医师(R1-R3)使用2D和3D MRI序列独立测量眼球突出度;同时获取一周内通过Hertel眼球突出计进行的临床测量作为对照。开发了一种自动化测量工具,并以资深放射科医师(R1)的手工标注作为金标准进行内部验证。为评估泛化能力,该工具在两个独立队列的轴位2D MRI数据集上进行了外部验证:中心2(n=65)和中心3(n=48)。基于眼眶MRI的测量在2D序列(ICC:0.948;95% CI:0.938-0.957)和3D序列(ICC:0.954;95% CI:0.939-0.966)中均表现出优异的观察者间一致性。MRI结果与Hertel眼球突出计测量呈强相关(Spearman's ρ=0.76-0.80)。该自动化工具在所有队列中均保持高性能,验证中的一致性相关系数(CCC)为0.928-0.973,组内相关系数(ICC)为0.916-0.973。这种基于MRI的自动化工具为Hertel眼球突出计提供了一种可靠、互补且标准化的替代方案,尤其在临床测量结果不一致或需要高精度纵向监测时尤为有用。该工具展现出优异的准确性、效率和跨中心泛化能力。
Accurate proptosis measurement change is critical for managing thyroid-associated ophthalmopathy (TAO), yet traditional Hertel exophthalmometry suffers from inter-observer inconsistency. This study aimed to investigate the efficacy of magnetic resonance imaging (MRI)-based proptosis measurement and developed an automated tool to enhance diagnostic reproducibility. We retrospectively analyzed data from 250 patients with TAO prospectively enrolled at Center 1 between December 2023 and June 2025. Proptosis was independently measured by three radiologists (R1-R3) using both 2D and 3D MRI sequences; clinical measurements via Hertel exophthalmometry were obtained within one week for comparison. An automated measurement tool was developed and internally validated using manual annotations from the senior radiologist (R1) as the ground truth. To assess generalizability, the tool was externally validated on axial 2D MRI datasets from two independent cohorts: Center 2 (n = 65) and Center 3 (n = 48). Orbital MRI-based measurements demonstrated excellent inter-observer agreement for both 2D (ICC: 0.948; 95% CI: 0.938-0.957) and 3D sequences (ICC: 0.954; 95% CI: 0.939-0.966). MRI findings showed a strong correlation with Hertel exophthalmometry (Spearman's ρ = 0.76-0.80). The automated tool maintained high performance across all cohorts, achieving concordance correlation coefficients (CCC) of 0.928-0.973 and intraclass correlation coefficients (ICC) of 0.916-0.973 in validation. This MRI-based automated tool provides a reliable, complementary, and standardized alternative to Hertel exophthalmometry, particularly useful when clinical measurements are discordant or demand high precision for longitudinal monitoring. It demonstrated excellent accuracy, efficiency, and cross-center generalizability.
Xinyi Gou, Cenyang Wu, Zhengyong Huang, Xiuying Zhang, Tianyuan Li, Lingli Zhou, et al. Reliability of Orbital MRI-Based Proptosis Measurement: A Multicenter Prospective Study.. Academic radiology. 2026; doi:10.1016/j.acra.2026.07.002.
Xinyi Gou, Cenyang Wu, Zhengyong Huang, Xiuying Zhang, Tianyuan Li, Lingli Zhou, et al (2026). Reliability of Orbital MRI-Based Proptosis Measurement: A Multicenter Prospective Study.. Academic radiology. https://doi.org/10.1016/j.acra.2026.07.002
Xinyi Gou, Cenyang Wu, Zhengyong Huang, Xiuying Zhang, Tianyuan Li, Lingli Zhou, et al. Reliability of Orbital MRI-Based Proptosis Measurement: A Multicenter Prospective Study.[J]. Academic radiology, 2026 doi:10.1016/j.acra.2026.07.002.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出