使用3D双回波稳态MRI和15通道下颌线圈对下颌神经进行高分辨率成像
High-resolution imaging of the mandibular nerve using 3D double-echo steady-state MRI and a 15-channel mandibular coil.
High-resolution imaging of the mandibular nerve using 3D double-echo steady-state MRI and a 15-channel mandibular coil.
评估优化高分辨率三维(3D)双回波稳态(DESS)磁共振成像(MRI)序列,联合专用15通道下颌线圈,在3T MRI上对健康志愿者下颌神经及其六条周围分支进行可视化的可行性。由三名具有不同经验水平和医学专业背景的读者对21名参与者的图像进行评估。采用5分视觉评分量表(5=最佳,1=最差)评估整体图像质量、伪影存在情况以及咬肌神经、颊神经、耳颞神经、舌神经、下牙槽神经和下颌舌骨神经近端与远端节段的神经连续性。计算描述性统计量及采用Krippendorff's alpha(α)评价的读者间一致性。图像质量始终被评为优秀,伪影极少(中位数5,IQR 5-5),读者间一致性高(α=0.87-0.92)。大多数分支实现了近端和远端节段的连续可视化,尤其是下牙槽神经和舌神经(中位数5,IQR 5-5)。较细分支的可视化更具挑战性,包括咬肌神经、下颌舌骨神经和颊神经(中位数4-4.5)。神经连续性评估的总体读者间一致性从良好到完美(α=0.79-1.0)。优化的高分辨率3D-DESS序列联合专用下颌线圈能够实现下颌神经及其周围分支可靠且可重复的可视化。
To evaluate the feasibility of an optimized high-resolution three-dimensional (3D) double-echo steady-state (DESS) magnetic resonance imaging (MRI) sequence, combined with a dedicated 15-channel mandibular coil, on 3T MRI for visualization of the mandibular nerve and its six peripheral branches in healthy volunteers. Images from 21 participants were assessed by three readers with varying levels of experience and medical specialties. Overall image quality, artifact presence, and nerve continuity across the proximal and distal segments of the masseteric, buccal, auriculotemporal, lingual, inferior alveolar, and mylohyoid nerves were evaluated using 5-point visual rating scales (5 = best, 1 = worst). Descriptive statistics and inter-reader agreement using Krippendorff's alpha (α) were calculated. Image quality was consistently rated as excellent with minimal artifacts (median 5, IQR 5-5) and high inter-reader agreement (α = 0.87-0.92). Continuous visualization of proximal and distal segments was achieved for most branches, particularly the inferior alveolar and lingual nerves (median 5, IQR 5-5). Visualization of thinner branches, including the masseteric, mylohyoid, and buccal nerves, was more challenging (median 4-4.5). Overall inter-reader agreement for nerve continuity assessment ranged from good to perfect (α = 0.79-1.0). An optimized high-resolution 3D-DESS sequence, combined with a dedicated mandibular coil, enables reliable and reproducible visualization of the mandibular nerve and its peripheral branches.
Nada Al-Haj Husain, Egon Burian, Bernd Stadlinger, Adib Al-Haj Husain, Maximilian Eberhard Hermann Wagner, Harald Essig, et al. High-resolution imaging of the mandibular nerve using 3D double-echo steady-state MRI and a 15-channel mandibular coil.. Oral surgery, oral medicine, oral pathology and oral radiology. 2026; doi:10.1016/j.oooo.2026.04.022.
Nada Al-Haj Husain, Egon Burian, Bernd Stadlinger, Adib Al-Haj Husain, Maximilian Eberhard Hermann Wagner, Harald Essig, et al (2026). High-resolution imaging of the mandibular nerve using 3D double-echo steady-state MRI and a 15-channel mandibular coil.. Oral surgery, oral medicine, oral pathology and oral radiology. https://doi.org/10.1016/j.oooo.2026.04.022
Nada Al-Haj Husain, Egon Burian, Bernd Stadlinger, Adib Al-Haj Husain, Maximilian Eberhard Hermann Wagner, Harald Essig, et al. High-resolution imaging of the mandibular nerve using 3D double-echo steady-state MRI and a 15-channel mandibular coil.[J]. Oral surgery, oral medicine, oral pathology and oral radiology, 2026 doi:10.1016/j.oooo.2026.04.022.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出