使用基于胸部放射线照相的深度学习模型对保留率受损肺活量进行机会性筛查的可行性
Feasibility of opportunistic screening for preserved ratio impaired spirometry using chest radiography-based deep learning models.
Feasibility of opportunistic screening for preserved ratio impaired spirometry using chest radiography-based deep learning models.
尽管使用胸部X线的深度学习模型可以估算肺功能测定值,但仍需进一步研究评估其筛查保留比值受损肺功能(PRISm)——一种重要的COPD前亚型——的能力。本研究评估了基于胸部X线的深度学习模型能否准确检测PRISm并进行高效的机会性筛查。本回顾性研究纳入了日本一家机构38470名健康体检参与者的54654对胸部X线与肺功能测定配对数据集,这些参与者在2018年和2019年于同日接受了胸部X线和肺功能测定。80%参与者的数据集用于模型开发,其余20%用于性能评估。我们开发了一个深度学习模型,利用后前位胸部X线和人口学标量输入来检测PRISm及其他肺功能障碍亚型,包括FEV₁下降、FVC下降、FVC和FEV₁下降以及气流受限。模型性能在内部测试数据集上进行评估。按五个独立因素进行亚组分析:年龄、身高、ppFVC、ppFEV₁和FEV₁/FVC。该模型在测试数据集(N = 10917)上检测PRISm的AUROC为0.892(95% CI,0.875-0.906),灵敏度为71.6%,特异度为87.9%。按年龄、身高、FEV₁/FVC或ppFEV₁定义的各亚组间AUROC无显著差异。检测所有肺功能障碍亚型的AUROC值均超过0.8。基于胸部X线的模型可有效检测PRISm,可能有助于PRISm的机会性筛查,以支持COPD前状态及阻塞性肺疾病的早期风险管理与干预。
Although deep learning models using chest radiographs can estimate spirometry measurements, further investigation is needed to evaluate their ability to screen for preserved ratio impaired spirometry (PRISm), an important pre-COPD subtype. This study assessed whether a chest radiograph-based deep learning model can accurately detect PRISm and perform efficient opportunistic screening. This retrospective study included 54654 paired chest radiography and spirometry datasets from 38470 health checkup participants at a Japanese institution who underwent chest radiography and spirometry on the same day in 2018 and 2019. The dataset of 80% participants was used for model development, and the remaining 20% was used for performance evaluation. We developed a deep learning model that used frontal chest radiographs and demographic scalar inputs to detect PRISm and other pulmonary dysfunction subtypes, including FEV₁ decline, FVC decline, FVC and FEV₁ decline, and airflow limitation. Model performance was evaluated on the internal testing dataset. Subgroup analyses were performed across five independent factors: age, height, ppFVC, ppFEV₁, and FEV₁/FVC. The model achieved an AUROC of 0.892 (95% CI, 0.875-0.906), a sensitivity of 71.6%, and a specificity of 87.9% for PRISm detection on the testing dataset (N = 10917). No significant differences in AUROC were observed across subgroups defined by age, height, FEV₁/FVC, or ppFEV₁. The AUROC values for detecting all pulmonary dysfunction subtypes exceeded 0.8. The chest radiography-based model can effectively detect PRISm and may be useful for opportunistic screening of PRISm for supporting early risk management and intervention for pre-COPD conditions and obstructive pulmonary diseases.
Akifumi Yoshida, Chiharu Kai, Ikumi Sato, Hitoshi Futamura, Kunihiko Oochi, Satoshi Kondo, et al. Feasibility of opportunistic screening for preserved ratio impaired spirometry using chest radiography-based deep learning models.. European journal of radiology open. 2026; doi:10.1016/j.ejro.2026.100791.
Akifumi Yoshida, Chiharu Kai, Ikumi Sato, Hitoshi Futamura, Kunihiko Oochi, Satoshi Kondo, et al (2026). Feasibility of opportunistic screening for preserved ratio impaired spirometry using chest radiography-based deep learning models.. European journal of radiology open. https://doi.org/10.1016/j.ejro.2026.100791
Akifumi Yoshida, Chiharu Kai, Ikumi Sato, Hitoshi Futamura, Kunihiko Oochi, Satoshi Kondo, et al. Feasibility of opportunistic screening for preserved ratio impaired spirometry using chest radiography-based deep learning models.[J]. European journal of radiology open, 2026 doi:10.1016/j.ejro.2026.100791.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出