改良Wells评分与CTPA确诊肺栓塞在影像学筛选队列中的一致性:一项回顾性单中心研究

Concordance of the modified wells score with CTPA-confirmed pulmonary embolism in an imaging-selected cohort: A retrospective single-center study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

肺栓塞(PE)是急诊医学中的一项重大诊断挑战。计算机断层扫描肺动脉造影(CTPA)是金标准,但常被过度使用。改良Wells评分(mWS)可评估检验前概率,并可能减少分诊时的不当影像检查。我们在某三级急诊科评估了mWS与CTPA确诊PE之间的一致性。我们回顾性分析了24个月内所有因疑似PE接受CTPA的患者。由于所有患者均已接受CTPA,该设计反映的是影像筛选队列内的一致性,而非分诊性能。mWS值由两名对CTPA结果设盲的阅片者协商确定;未纳入D-二聚体。AUC基于mWS完整有序范围计算;敏感度、特异度、PPV和NPV按常规mWS≥4阈值计算。采用Spearman相关评估mWS与PE严重程度的相关性。在691例患者中,103例(14.9%)经CTPA确诊PE。以mWS≥4为阈值时,敏感度为86.4%,特异度为98.6%,AUC为0.943(95%CI:0.91-0.97)。Youden指数确定mWS≥3为最佳阈值(敏感度89.3%,特异度95.7%);分析中仍保留≥4。在该阈值下,594例患者(86.0%)低于截断值,提示可能存在可避免的影像检查,但未在未接受影像检查的患者中证实。共识别出14例假阴性和8例假阳性病例,其中假阴性中3例为中心型PE。较高的mWS与PE负荷呈中度相关(ρ=0.578,p<0.01)。mWS与CTPA确诊PE显示出强一致性;其诊断准确度超过汇总荟萃分析估计值,可能反映的是共识评分方法学,而非真正的优越性。在常规实施前,有必要开展纳入D-二聚体检测和独立评分的前瞻性、多中心验证。

Abstract

Pulmonary embolism (PE) is a major diagnostic challenge in emergency medicine. Computed tomography pulmonary angiography (CTPA) is the gold standard but is frequently overused. The modified Wells Score (mWS) estimates pre-test probability and may reduce inappropriate imaging at triage. We evaluated the concordance between mWS and CTPA-confirmed PE in a tertiary emergency department. We retrospectively analyzed all patients undergoing CTPA for suspected PE over 24 months. As all patients had already undergone CTPA, this design reflects concordance within an imaging-selected cohort, not triage performance. mWS values were assigned by consensus between two readers, blinded to CTPA results; D-dimer was not incorporated. AUC was computed from the full ordinal mWS range; sensitivity, specificity, PPV and NPV were calculated at the conventional mWS ≥ 4 threshold. Spearman's correlation assessed the mWS-PE severity association. Among 691 patients, 103 (14.9%) had CTPA-confirmed PE. At mWS ≥ 4, sensitivity was 86.4%, specificity 98.6%, AUC 0.943 (95% CI: 0.91-0.97). The Youden index identified mWS ≥ 3 as optimal (sensitivity 89.3%, specificity 95.7%); ≥ 4 was retained for analysis. Under this threshold, 594 patients (86.0%) fell below the cut-off, suggesting avoidable imaging, though unconfirmed in non-imaged patients. Fourteen false-negative (3 central PE) and eight false-positive cases were identified. Higher mWS correlated moderately with PE burden (ρ = 0.578, p < 0.01). mWS showed strong concordance with CTPA-confirmed PE; diagnostic accuracy exceeding pooled meta-analytic estimates likely reflects consensus-scoring methodology rather than genuine superiority. Prospective, multicentre validation incorporating D-dimer testing and independent scoring is warranted before routine implementation.

如何引用

AMA

Pietro Costantini, Eleonora Ostillio, Davide Razzini, Rita Spagnolo, Davide Fabbricatore, Anna Carmen Leonetti, et al. Concordance of the modified wells score with CTPA-confirmed pulmonary embolism in an imaging-selected cohort: A retrospective single-center study.. European journal of radiology open. 2026; doi:10.1016/j.ejro.2026.100811.

APA

Pietro Costantini, Eleonora Ostillio, Davide Razzini, Rita Spagnolo, Davide Fabbricatore, Anna Carmen Leonetti, et al (2026). Concordance of the modified wells score with CTPA-confirmed pulmonary embolism in an imaging-selected cohort: A retrospective single-center study.. European journal of radiology open. https://doi.org/10.1016/j.ejro.2026.100811

GB/T 7714

Pietro Costantini, Eleonora Ostillio, Davide Razzini, Rita Spagnolo, Davide Fabbricatore, Anna Carmen Leonetti, et al. Concordance of the modified wells score with CTPA-confirmed pulmonary embolism in an imaging-selected cohort: A retrospective single-center study.[J]. European journal of radiology open, 2026 doi:10.1016/j.ejro.2026.100811.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

European journal of radiology open 的其他文献