7.0特斯拉MRI在胎儿尸检中的应用:在多学科工作流程中整合图像优化与临床实践的初步探索
7.0 Tesla MRI in fetal autopsy: a preliminary exploration of integrating image optimization with clinical practice in a multidisciplinary workflow.
7.0 Tesla MRI in fetal autopsy: a preliminary exploration of integrating image optimization with clinical practice in a multidisciplinary workflow.
胎儿和新生儿尸检对于明确死亡原因和指导未来妊娠至关重要;然而,受文化和个人因素的影响,其临床应用率正在下降。无创死后磁共振成像(PMMRI)已成为胎儿和新生儿尸检的替代方法。超高场7.0特斯拉(7.0T)PMMRI与低场磁共振成像(MRI)相比,可提供接近显微镜级的空间分辨率、更优的组织对比度和高信噪比。然而,其更广泛的临床应用受到严格的标本保存要求、复杂的扫描参数以及缺乏标准化多学科工作流程的制约。因此,本研究旨在建立胎儿7.0T PMMRI的多学科方案,基于实践经验优化技术参数,并验证其与病理尸检结果的诊断一致性。本单中心工作流程优化研究纳入20例引产胎儿(平均胎龄26.4周)。20例胎儿中,19例接受了最终病理尸检,13例此前接受过1.5T MRI评估。系统应用计划-执行-检查-处理(PDCA)循环以改进尸体准备、成像序列和多学科协作。采用Cohen kappa系数对1.5T MRI、死后7.0T PMMRI与病理尸检之间的诊断一致性进行统计分析。7.0T PMMRI工作流程在五个关键方面得到优化:尸体选择与准备、7.0T MRI设置、人员准备、数据处理和多学科死亡审查。为确保图像质量并尽量减少与冷冻、压迫和自溶相关的问题,建立了严格的死后预处理措施,包括应在4 ℃下24小时内进行成像。通过选择合适的磁共振(MR)线圈和序列[如T2加权成像自旋回波(T2WI-SE)和磁敏感加权成像(SWI)],扫描方案优化至持续60-120分钟。一致性分析显示,7.0T PMMRI与病理尸检之间具有极佳的诊断一致性(Cohen kappa=0.872,P<0.001),显著高于1.5T MRI与尸检之间的一致性(Cohen kappa=0.22)。通过PDCA循环将7.0T PMMRI整合到结构化的多学科工作流程中,有效提高了标准化程度、操作效率和图像质量。高分辨率7.0T PMMRI与传统尸检表现出高度诊断一致性,支持其作为胎儿死后检查中有价值且可靠的无创替代方法。
Fetal and neonatal autopsies are crucial for determining causes of death and guiding future pregnancies; however, due to cultural and personal factors, their clinical application rates are decreasing. Noninvasive postmortem magnetic resonance imaging (PMMRI) has emerged as an alternative to fetal and neonatal autopsies. Ultra-high-field 7.0 Tesla (7.0T) PMMRI provides near-microscopic spatial resolution, superior tissue contrast, and a high signal-to-noise ratio compared to lower-field magnetic resonance imaging (MRI). However, its broader clinical application is challenged by stringent specimen preservation requirements, complex scanning parameters, and a lack of standardized multidisciplinary workflows. Thus, this study aimed to establish a multidisciplinary protocol for 7.0T PMMRI in fetuses, optimize the technical parameters based on practical experience, and validate its diagnostic consistency with pathological autopsy findings. This single-center workflow-optimization study included 20 fetuses delivered by induced labor (mean gestational age 26.4 weeks). Of the 20 fetuses, 19 underwent final pathological autopsy, and 13 had previously undergone 1.5T MRI evaluations. A Plan-Do-Check-Act (PDCA) cycle was systematically applied to refine cadaver preparation, imaging sequences, and multidisciplinary collaboration. Diagnostic consistency among 1.5T MRI, postmortem 7.0T PMMRI, and pathological autopsy was statistically analyzed using Cohen's kappa coefficient. The 7.0T PMMRI workflow was optimized across five key aspects: body selection and preparation, 7.0T MRI setup, personnel readiness, data processing, and multidisciplinary death review. To ensure image quality and minimize issues related to freezing, compression, and autolysis, strict postmortem pretreatments were established, including that imaging should be conducted within 24 hours at 4 ℃. Scanning protocols were optimized to a duration of 60-120 minutes through the selection of appropriate magnetic resonance (MR) coils and sequences [e.g., T2-weighted imaging spin-echo (T2WI-SE) and susceptibility-weighted imaging (SWI)]. The consistency analysis revealed excellent diagnostic agreement between 7.0T PMMRI and pathological autopsy (Cohen's kappa =0.872, P<0.001), a value significantly higher than that between 1.5T MRI and autopsy (Cohen's kappa =0.22). Integrating 7.0T PMMRI into a structured multidisciplinary workflow via the PDCA cycle effectively improved standardization, operational efficiency, and image quality. High-resolution 7.0T PMMRI exhibited high diagnostic consistency with traditional autopsy, supporting its role as a valuable and reliable noninvasive alternative for fetal postmortem examinations.
Yuhan Zhang, Zhiming Zhen, Ping Cai, Limei Wang, Dan Wang, Chen Liu, et al. 7.0 Tesla MRI in fetal autopsy: a preliminary exploration of integrating image optimization with clinical practice in a multidisciplinary workflow.. Quantitative imaging in medicine and surgery. 2026; doi:10.21037/qims-2025-2079.
Yuhan Zhang, Zhiming Zhen, Ping Cai, Limei Wang, Dan Wang, Chen Liu, et al (2026). 7.0 Tesla MRI in fetal autopsy: a preliminary exploration of integrating image optimization with clinical practice in a multidisciplinary workflow.. Quantitative imaging in medicine and surgery. https://doi.org/10.21037/qims-2025-2079
Yuhan Zhang, Zhiming Zhen, Ping Cai, Limei Wang, Dan Wang, Chen Liu, et al. 7.0 Tesla MRI in fetal autopsy: a preliminary exploration of integrating image optimization with clinical practice in a multidisciplinary workflow.[J]. Quantitative imaging in medicine and surgery, 2026 doi:10.21037/qims-2025-2079.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出