深吸气有助于在III型椎弓中极其曲折的椎动脉口进行支架植入
Deep inspiration-facilitated stenting for extremely tortuous vertebral artery ostium in a Type III arch.
Deep inspiration-facilitated stenting for extremely tortuous vertebral artery ostium in a Type III arch.
在存在严重主动脉弓上迂曲的情况下,椎动脉开口(VAO)狭窄的血管内治疗在技术上可能具有挑战性,尤其是III型主动脉弓,此时稳定的导引导管定位往往难以维持。在器械输送过程中,近端支撑不足可能导致导引导管脱入主动脉弓,从而影响手术成功。尽管诸如双导丝技术等辅助支撑技术可能改善系统稳定性,但极端的血管迂曲仍可能阻碍球囊或支架的推进。1 深吸气并短暂屏气动作可通过诱导主动脉弓和近端锁骨下动脉向尾侧移位来促进器械输送。2 由于远端椎动脉在横突孔内保持相对固定,该动作会在V1段产生暂时的轴向张力,部分拉直迂曲的血管走行并改善器械的跟踪性。3 本技术视频(视频1)演示了一例极迂曲右侧VAO病变的逐步血管内重建过程,该患者此前因不利的血管解剖导致支架置入失败并随后出现再狭窄。尽管为III型主动脉弓解剖,由于开口处几何形态陡峭,必须选择经股动脉入路而非经桡动脉入路,以提供必要的顺行输送向量。我们重点介绍一种双重策略方法,即结合远端导丝锚定支撑以增强导引稳定性,以及呼吸诱导的血管拉直以促进器械导航,最终实现精准的支架释放和完全血运重建。neurintsurg;jnis-2026-025713v1/V1F1V1视频1。
Endovascular treatment of vertebral artery ostial (VAO) stenosis can be technically challenging in the presence of severe supra-aortic tortuosity, particularly a Type III aortic arch where stable guide catheter positioning is often difficult to maintain. During device delivery, inadequate proximal support may result in guide catheter prolapse into the aortic arch, compromising procedural success. Although adjunctive support techniques such as the buddy-wire technique may improve system stability, extreme vascular tortuosity can still impede the advancement of balloons or stents.1 A deep inspiration maneuver with transient breath-holding may facilitate device delivery by inducing caudal displacement of the aortic arch and proximal subclavian artery.2 Because the distal vertebral artery remains relatively fixed within the transverse foramina, this maneuver generates temporary axial tension across the V1 segment, partially straightening the tortuous vascular course and improving device trackability.3This technical video (video 1) demonstrates step-by-step endovascular reconstruction of an extremely tortuous right VAO lesion in a patient with prior failed stenting caused by hostile vascular anatomy and subsequent recurrent stenosis. Despite the Type III arch anatomy, a transfemoral approach was mandated over a radial approach due to the acute ostial geometry, providing the necessary antegrade delivery vector. We highlight a dual strategy approach combining distal wire-anchor support to enhance guiding stability and respiratory-induced vascular straightening to facilitate device navigation, ultimately enabling precise stent deployment and complete revascularization.neurintsurg;jnis-2026-025713v1/V1F1V1Video 1.
Ying Tan, Na Duan, Bo Wang, Ning Ma. Deep inspiration-facilitated stenting for extremely tortuous vertebral artery ostium in a Type III arch.. Journal of neurointerventional surgery. 2026; doi:10.1136/jnis-2026-025713.
Ying Tan, Na Duan, Bo Wang, Ning Ma (2026). Deep inspiration-facilitated stenting for extremely tortuous vertebral artery ostium in a Type III arch.. Journal of neurointerventional surgery. https://doi.org/10.1136/jnis-2026-025713
Ying Tan, Na Duan, Bo Wang, Ning Ma. Deep inspiration-facilitated stenting for extremely tortuous vertebral artery ostium in a Type III arch.[J]. Journal of neurointerventional surgery, 2026 doi:10.1136/jnis-2026-025713.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出