Journal of NeuroInterventional Surgery神经介入外科杂志
Journal of NeuroInterventional Surgery(英文缩写 J NEUROINTERV SURG),ISSN 1759-8478,eISSN 1759-8486,中文译名:神经介入外科杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 8.572 | Q1 |
| 2022 | 4.800 | Q1 |
| 2023 | 4.500 | Q1 |
| 2024 | 4.300 | Q1 |
| 2025 | 4.400 | Q1 |
Journal of NeuroInterventional Surgery 最新收录文献
-
1. RESTORE: REal-world analyses of Stroke-Thrombus Occlusion REtrieval study: effectiveness, safety, and technical outcomes.
1. RESTORE:卒中血栓闭塞取栓术真实世界分析研究:有效性、安全性和技术结局PMID:日期:2026-09-24Mechanical thrombectomy has become the cornerstone of treatment for acute ischemic stroke (AIS) caused by large vessel occlusion. While randomized trials have established non-inferiority of aspiration-based approaches compared with stent retriever approaches, real-world evidence is essential to evaluate device performance across heterogeneous populations, anatomies, and procedural strategies. The objective of the RESTORE registry is to report the final results and contextualize its findings within the evolving landscape of large- and super-large-bore aspiration catheter technologies. RESTORE (REal-world analyses of Stroke-Thrombus Occlusion REtrieval study) is a prospective, multicenter, observational registry enrolling AIS patients treated with Terumo Neuro devices as a first-line mechanical thrombectomy approach. Angiographic and safety outcomes were evaluated by an independent core laboratory and clinical events committee, respectively. Among 710 enrolled patients across 36 centers, 688 comprised the final analysis cohort. Final reperfusion (modified Thrombolysis In Cerebral Infarction (mTICI) ≥2b) was achieved in 93.0%, with first-pass mTICI ≥2b in 60.8%. Median puncture-to-clot contact and puncture-to-reperfusion times were 13 and 17 min, respectively. Symptomatic intracranial hemorrhage occurred in 0.6% of patients, and the all-cause mortality rate at 90 days was 16.3%. Embolization to new territory occurred in 0.4%, and 52.9% of patients achieved functional independence (modified Rankin Scale ≤2) at 90 days. RESTORE represents one of the largest prospective real-world registries evaluating a SOFIA-dominant first-line thrombectomy approach using Terumo Neuro devices for AIS due to intracranial vessel occlusion. Under routine practice conditions, the registry demonstrated favorable angiographic, procedural, and clinical outcomes with a reassuring safety profile, supporting aspiration-dominant approaches as an effective and safe first-line strategy in this setting. However, because RESTORE was observational, single-arm, and descriptive, these findings should be interpreted as real-world evidence of feasibility and safety rather than proof of comparative efficacy or superiority over other thrombectomy strategies.
-
2. Preprocedural high-resolution vessel wall MRI predicts in-stent restenosis after intracranial stenting.
2. 术前高分辨率血管壁MRI可预测颅内支架置入术后支架内再狭窄PMID:日期:2026-09-24In-stent restenosis (ISR) remains a challenge after intracranial stenting for intracranial atherosclerotic stenosis (ICAS). We evaluated whether preprocedural high-resolution vessel wall imaging (HR-VWI) features and clinical factors could predict ISR. We retrospectively analyzed 237 ICAS patients undergoing intracranial stenting with preprocedural HR-VWI and follow-up. Clinical and HR-VWI parameters were compared between ISR and non-ISR groups using the Mann-Whitney U and χ tests. Predictors were identified using LASSO (least absolute shrinkage and selection operator) Cox regression. A 1-year risk prediction model was constructed and visualized as a nomogram. Model performance was evaluated using C-index, calibration, decision curve analysis, and bootstrap validation. Kaplan-Meier analysis assessed ISR incidence over time. ISR occurred in 42 patients (17.7%) during follow-up, including 38 cases (16.0%) within 1 year. Mean normalized wall index (NWI) (per 10% increase; HR 2.37, 95% CI 1.51 to 3.73, P<0.001), plaque length (HR 1.12, 95% CI 1.03 to 1.22, P=0.010), and enhancement ratio (HR 2.27, 95% CI 1.07 to 4.82, P=0.034), along with residual stenosis (per 10% increase; HR 1.42, 95% CI 1.09 to 1.85, P=0.010), were independent predictors. The model showed good discrimination (C-index 0.79, 95% CI 0.72 to 0.86), calibration, and net benefit. Higher ISR risk was observed with mean NWI ≥0.88, plaque length ≥8 mm, enhancement ratio ≥1.07, or residual stenosis ≥39% (all P≤0.01). Preprocedural HR-VWI-derived mean NWI, plaque length, and enhancement ratio, together with residual stenosis, were associated with ISR and may aid risk stratification. Further validation in larger prospective cohorts is warranted.
-
3. Anxiety and mood disorders are associated with greater healthcare and procedural utilization in idiopathic intracranial hypertension.
3. 焦虑和情绪障碍与特发性颅内高压患者更高的医疗保健和操作利用相关PMID:日期:2026-09-18Anxiety and mood disorders (AMD) are common in idiopathic intracranial hypertension (IIH), but their association with procedural treatment and healthcare utilization is unclear. We evaluated utilization among patients with AMD documented before or shortly after IIH. Using the TriNetX US Collaborative Network, we identified adults diagnosed with IIH on or after January 1, 2016. The primary analysis compared patients with AMD documented on or before IIH with those without AMD; the sensitivity analysis compared patients with a first AMD diagnosis within 1 month after IIH with those without AMD before or during that month. Each analysis used separate 1:1 propensity-score matching. 5-year outcomes were assessed using Kaplan-Meier methods and Cox regression. The primary analysis included 38 117 matched patients per group. At 5 years, patients with AMD had higher rates of cerebrospinal fluid shunting (5.86% vs 4.62%; HR 1.168), transverse venous sinus stenting (1.40% vs 1.09%; HR 1.236), either procedure (7.12% vs 5.61%; HR 1.178), inpatient admission (45.63% vs 36.88%; HR 1.214), and emergency department visits (56.57% vs 42.57%; HR 1.519), but lower mortality (7.70% vs 9.67%; HR 0.725). The sensitivity analysis included 8949 matched patients per group and showed the same pattern among patients with AMD newly diagnosed within 1 month after IIH. AMD documented before or shortly after IIH was associated with greater procedural and healthcare utilization. These observational findings describe patterns of care but do not establish that AMD causes greater IIH severity or procedural need.
-
4. Predicting futile recanalization after mechanical thrombectomy in patients with ischemic stroke and cancer: the CACTUS nomogram.
4. 预测缺血性卒中合并癌症患者机械取栓术后无效再通:CACTUS列线图PMID:日期:2026-09-18Patients with large vessel occlusion (LVO) and a history of cancer have worse long-term outcomes after mechanical thrombectomy (MT) despite similar reperfusion rates. We aimed to develop a clinical prognostic score to predict futile recanalization (FR) in this population. We retrospectively analyzed a single-center prospective registry (ARTISTA) of patients with LVO and active or previous cancer who underwent MT between January 2021 and December 2023. The primary outcome was FR, defined as successful angiographic reperfusion (expanded Thrombolysis in Cerebral Infarction (eTICI) ≥2b) with poor functional outcome (modified Rankin Scale (mRS) ≥3) at 90 days. A clinically prespecified logistic regression model was developed to predict FR. Model performance was assessed, and internal validation was performed using bootstrap resampling and repeated cross-validation. An expanded penalized least absolute shrinkage and selection operator (LASSO) model was evaluated as a secondary analysis and a nomogram was derived from the final model. Of 1584 patients who underwent MT during the study period, 167 patients with a history of cancer met the eligibility criteria for analysis. FR occurred in 50.9% of patients. A clinically prespecified prediction model included age, pre-stroke mRS score, admission National Institutes of Health Stroke Scale (NIHSS) score, and metastatic disease. A higher pre-stroke mRS score (adjusted OR (aOR) 1.84, 95% CI 1.09 to 3.21; P=0.025), higher admission NIHSS score (aOR 1.11 per point, 95% CI 1.05 to 1.17; P<0.001), and metastatic disease (aOR 8.38, 95% CI 2.77 to 31.93; P<0.001) were independently associated with FR. Internal bootstrap validation yielded an optimism-corrected AUC of 0.758 and a Brier score of 0.206. An optimism-corrected nomogram was derived for clinical use. The CACTUS prediction model showed adequate predictive performance for FR, and the derived nomogram may serve as a practical tool for individualized risk assessment in patients with LVO who are candidates for MT and have a history of cancer.
-
5. Balloon guide catheter outcomes by occlusion site in the randomized PROTECT-MT trial.
5. 随机PROTECT-MT试验中按闭塞部位分层的球囊导引导管结局PMID:日期:2026-09-18Balloon guide catheters (BGCs) are used during endovascular thrombectomy, but whether their effect varies by occlusion site is uncertain. We evaluated effect modification by baseline occlusion site in the PROTECT-MT trial. This exploratory secondary analysis of the randomized PROTECT-MT trial included patients with core laboratory-adjudicated anterior circulation occlusion site data. Patients were classified as having intracranial internal carotid artery (ICA), M1, or M2 occlusion. The primary outcome was the 90-day modified Rankin Scale (mRS) distribution. Treatment effect modification was assessed using adjusted ordinal logistic regression with a treatment-by-occlusion site interaction term. The parent plan prespecified internal carotid artery (ICA) versus middle cerebral artery (MCA) occlusions; the three-level comparison and post hoc Holm correction of 19 secondary interactions were exploratory. Among 329 patients, 88 (26.7%) had ICA occlusions, 206 (62.6%) M1 occlusions, and 35 (10.6%) M2 occlusions. The interaction for the 90-day mRS distribution was not statistically significant (P=0.072). Adjusted common ORs with BGC versus control were 0.38 (95% CI 0.17 to 0.85) for ICA occlusions, 0.60 (95% CI 0.36 to 0.99) for M1 occlusions, and 4.32 (95% CI 0.53 to 35.02) for M2 occlusions. No consistent interaction was observed for first-pass or final reperfusion. Secondary interaction analyses remained exploratory after post hoc multiplicity correction. This exploratory analysis did not provide conclusive evidence that the occlusion site modified the effect of BGC use on 90-day outcome. Imprecise estimates, particularly for M2, preclude site-specific guide catheter selection. NCT05592054.
-
6. Atlas self-expandable stents versus low profile visualized intraluminal support stents for intracranial aneurysm coiling assistance: systematic review and meta-analysis.
PMID:日期:2026-09-16Neurointerventionalists performing stent assisted coil embolization for intracranial aneurysms use Neuroform Atlas stents (Stryker) for their low metal coverage, deployment ease, and lower thromboembolic risk, although low profile visualized intraluminal support (LVIS) and LVIS Jr stents (Terumo Neuro) offer better wall apposition and high metal coverage, potentially promoting flow diversion and endothelialization. The next generation LVIS Evolution (LVIS EVO; Terumo Neuro) adds enhanced visibility, improved resheathability, and even higher metal coverage to address earlier limitations of LVIS and LVIS Jr. We evaluated the performance and complications of these devices. PubMed and Embase were searched from 1 January 2017 to 31 July 2025 to identify studies comparing Atlas assisted coil embolization (AACE) versus LVIS/LVIS Jr assisted coil embolization (LACE), and single arm LVIS EVO assisted coil embolization (LeACE) studies. Meta-analyses were performed to compare baselines, procedural considerations, and occlusion rates. We included five studies comparing 504 patients treated with AACE and 579 patients with LACE, and 12 studies evaluating LeACE (575 patients). Fewer aneurysms were ruptured at presentation in the AACE group than in the LACE (OR 0.09; P<0.01) and LeACE (0.7% vs 15.2%; P<0.01) groups. Comparable technical failure rates were found between AACE and LeACE (1.8% vs 5.4%; P=0.15), contrasting with the superiority of AACE over LACE (OR 0.14; P<0.01). AACE resulted in higher immediate adequate occlusion than LACE (OR 1.62; P=0.02), but comparable with LeACE (83% vs 90.8%; P=0.28). Follow-up complete occlusion rates were similar between AACE and LACE (OR 1.31; P=0.16) and between AACE and LeACE (82.4% vs 81.2%; P=0.86). The superior outcomes of the Atlas over LVIS/LVIS Jr were matched by the LVIS EVO. Thromboembolic complications occurred more frequently with the LVIS EVO.
-
8. Endovascular treatment for Spetzler-Martin grade IV-V brain arteriovenous malformations: a 26-year single-center cohort study.
8. Spetzler-Martin IV-V级脑动静脉畸形的血管内治疗:一项26年单中心队列研究PMID:日期:2026-09-15The exclusion treatment of Spetzler-Martin grade (SMG) IV-V brain arteriovenous malformations (bAVMs) remains controversial. This study evaluates the safety and effectiveness of endovascular treatment (EVT) for SMG IV-V bAVMs, either as a standalone strategy or as part of multimodal management. A retrospective single-center observational cohort study of consecutive adult patients with SMG IV-V bAVMs treated with EVT between 1998 and 2024 was conducted. Baseline characteristics, procedure-related complications, clinical outcomes, and angiographic follow-up were recorded. Independent risk factors for EVT-related complications were analyzed using binary logistic regression. A total of 73 patients with 73 SMG IV-V bAVMs were included. The median age was 36 (IQR 28-47) years, and 29 (39.7%) bAVMs were ruptured at presentation. Complete angiographic obliteration by EVT alone in intention to cure was achieved in 6/33 patients (18.2%). Overall, complete angiographic obliteration was achieved in 33 patients (45.2%), either by EVT alone or within a multimodal treatment strategy. EVT-related major complications (shift in modified Rankin Scale score of ≥2 or death) occurred in eight patients (11.0%). The presence of a flow-related proximal aneurysm was independently associated with EVT-related complications (OR 4.47; 95% CI 1.18 to 16.98; P=0.028). In this single-center retrospective series, EVT for SMG IV-V bAVMs was associated with a substantial procedural risk and achieved complete obliteration only in a limited proportion of patients when used as a standalone treatment. Within a multimodal management strategy higher angiographic exclusion rates were observed, although it remained associated with substantial morbidity.
-
9. Computational fluid dynamics-derived flow helicity and recurrent stroke risk in symptomatic intracranial stenosis.
9. 计算流体动力学衍生的血流螺旋度与症状性颅内狭窄复发性卒中风险PMID:日期:2026-09-15Patients with symptomatic intracranial atherosclerotic stenosis (ICAS) remain at risk of recurrent ischemic events despite treatment. Stenosis severity is routinely used for risk assessment, but does not describe the lesion-level flow field. We used computational fluid dynamics (CFD) to assess whether flow helicity within the culprit stenosis was associated with 1-year target-vessel stroke. We studied 204 adults with symptomatic ICAS who underwent CT angiography-based vascular reconstruction and CFD analysis. The prespecified exposure was maximum absolute flow helicity at the narrowest cross-sectional plane of the culprit stenosis, transformed using log(1+x) and standardized per SD. The primary outcome was 1-year target-vessel stroke, and the secondary endpoint was target-territory stroke or vascular death. Multivariable Cox models adjusted for major clinical, anatomical, and hemodynamic covariates were supplemented by Kaplan-Meier, cutpoint, tertile, subgroup, and Winsorization analyses. Multivariable analyses included 203 patients. During follow-up, 31 target-vessel strokes and 33 composite events occurred. Each 1 SD increase in log-transformed maximum absolute helicity was associated with target-vessel stroke (HR 1.461, 95% CI 1.049 to 2.035, P=0.0249). The association with the composite endpoint was directionally similar but not significant (HR 1.351, 95% CI 0.973 to 1.875, P=0.0720). Median-split Kaplan-Meier curves separated for both outcomes, and tertile analysis showed higher target-vessel stroke risk in the highest versus lowest tertile (HR 2.951, 95% CI 1.067 to 8.160, P=0.0371). In symptomatic ICAS, higher lesion-level maximum absolute helicity was associated with 1-year target-vessel stroke, supporting further evaluation of helicity as a CFD-derived marker of flow disturbance.
-
10. Workflow level release of microplastics, nanoplastics, and perfluoroalkyl and polyfluoroalkyl substances during simulated neurovascular interventions.
10. 模拟神经血管介入过程中微塑料、纳米塑料以及全氟和多氟烷基物质的工作流程级释放PMID:日期:2026-09-15Catheter based neurovascular interventions rely on polymer based, coated, and fluorinated devices. Mechanical manipulation may release particulate and molecular contaminants, but integrated workflow level quantification of microplastic (MP), nanoplastic (NP), and perfluoroalkyl and polyfluoroalkyl substance (PFAS) release during neurovascular procedures remains limited. This study quantified MP, NP, and PFAS release in an in vitro simulation of neurointerventional workflows. 20 neurovascular procedures were simulated under standardized in vitro conditions, including 10 mechanical thrombectomy and 10 aneurysm treatment workflows. Procedures were performed in 5 L glass containers using warmed saline, contrast medium, and clinically applied neurovascular devices. Procedural fluid was collected after each simulation and aliquoted for MP, NP, and PFAS analysis using micro-Fourier transform infrared spectroscopy, pyrolysis-gas chromatography-mass spectrometry, and ultra high performance liquid chromatography-tandem mass spectrometry, respectively. Contaminants were detected across all simulated procedures. Median MP particle count was 15 particles per analyzed sample volume (IQR 9.0-27.3; range 0-58), median NP concentration was 18.19 µg/L (IQR 5.85-33.35; range 2.19-1671.10), and median sum PFAS concentration was 127 µg/L (IQR 93.5-272.0; range 47-458). MP and NP levels did not differ between thrombectomy and aneurysm simulations. Sum PFAS concentrations were higher during thrombectomy than during aneurysm treatment simulations (median 209.5 vs 98.0 µg/L; P=0.010), particularly in stent retriever compared with direct aspiration simulations (median 287.0 vs 120.0 µg/L; P=0.030). NP and sum PFAS concentrations were strongly correlated (ρ=0.689; P=0.001). Simulated neurovascular interventions generated measurable release of MP, NP, and PFAS into procedural fluid. Workflow level assessment may support future source specific testing, clinical validation, and material safety evaluation.