微创二尖瓣手术插管策略的比较
Comparison of Cannulation Strategies for Minimally Invasive Mitral Valve Surgery.
Comparison of Cannulation Strategies for Minimally Invasive Mitral Valve Surgery.
微创二尖瓣手术(MIV-MVS)通过外科技术和围手术期管理的改进而不断发展。本研究评估了动脉插管策略与围手术期不良事件之间的关联。研究采用了三种动脉插管方式:中央升主动脉插管(AC)、经腹股沟切开直视股动脉插管(oFC)以及使用预闭合装置的经皮股动脉插管(pFC)。来自2个中心的患者接受了复合安全性终点(30天死亡率或卒中)、复合有效性终点(全因死亡、卒中或插管相关不良事件)以及术后谵妄的评估。插管相关不良事件包括转为胸骨切开或再次开胸、血管夹层或出血以及插管部位感染。2013年1月至2020年1月期间,823例患者接受了MIV-MVS。266例(32.3%)行主动脉插管,396例(48.1%)行oFC,161例(19.6%)行pFC。30天全因死亡或卒中的复合终点发生于19例患者(2.3%),AC与FC之间无显著差异(比值比[OR] 1.16,95% CI,0.41-3.16)。扩展复合有效性终点在AC组的发生率低于任何FC组(OR 0.46,95% CI,0.21-0.94),主要归因于较少的穿刺部位并发症。主动脉插管还与较低的围手术期谵妄发生率相关(OR 0.51,95% CI,0.29-0.86)。oFC与pFC之间未观察到显著差异。在接受MIV-MVS的患者中,不同插管策略的30天死亡或卒中发生率相似。与FC相比,主动脉插管与较低的插管相关并发症发生率和较少的围手术期谵妄相关,这主要反映了较少的穿刺部位并发症。尚需进一步的前瞻性外部验证。
Minimally invasive mitral valve surgery (MIV-MVS) continues to evolve through refinements in surgical technique and perioperative management. This study evaluated the association between arterial cannulation strategy and perioperative adverse events. Three arterial cannulations were used: central ascending aortic cannulation (AC), open femoral cannulation via groin cutdown (oFC), and percutaneous femoral cannulation (pFC) using pre-closure devices. Patients from 2 centres were assessed for the composite safety end-point of 30-day mortality or stroke, the composite efficacy end-point of all-cause death, stroke, or cannulation-related adverse events, and postoperative delirium. Cannulation-related adverse events included conversion to sternotomy or re-thoracotomy, vessel dissection or bleeding, and cannulation-site infection. Between January 2013 and January 2020, 823 patients underwent MIV-MVS. Aortic cannulation was performed in 266 patients (32.3%), oFC in 396 (48.1%), and pFC in 161 (19.6%). The composite end-point of 30-day all-cause death or stroke occurred in 19 patients (2.3%) and was similar between AC and FC (odds ratio [OR] 1.16, 95% CI, 0.41-3.16). The extended composite efficacy end-point occurred less frequently with AC than with any FC (OR 0.46, 95% CI, 0.21-0.94), mainly due to fewer access-site complications. Aortic cannulation was also associated with lower odds of perioperative delirium (OR 0.51, 95% CI, 0.29-0.86). No significant difference was observed between oFC and pFC. In patients undergoing MIV-MVS, 30-day death or stroke was similar across cannulation strategies. Aortic cannulation was associated with a lower rate of cannulation-related complications and less perioperative delirium than FC, largely reflecting fewer access-site complications. Further prospective external validation is warranted.
Juri Sromicki, Nestoras Papadopoulos, Lisa Tröbinger, Vasileios Ntinopoulos, Monika Hebeisen, Milan Milojevic, et al. Comparison of Cannulation Strategies for Minimally Invasive Mitral Valve Surgery.. Interdisciplinary cardiovascular and thoracic surgery. 2026; doi:10.1093/icvts/ivag185.
Juri Sromicki, Nestoras Papadopoulos, Lisa Tröbinger, Vasileios Ntinopoulos, Monika Hebeisen, Milan Milojevic, et al (2026). Comparison of Cannulation Strategies for Minimally Invasive Mitral Valve Surgery.. Interdisciplinary cardiovascular and thoracic surgery. https://doi.org/10.1093/icvts/ivag185
Juri Sromicki, Nestoras Papadopoulos, Lisa Tröbinger, Vasileios Ntinopoulos, Monika Hebeisen, Milan Milojevic, et al. Comparison of Cannulation Strategies for Minimally Invasive Mitral Valve Surgery.[J]. Interdisciplinary cardiovascular and thoracic surgery, 2026 doi:10.1093/icvts/ivag185.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出