超高能量体外交联角膜同种异体基质内环段(ECO-CAIRS)的脱水和再水化行为

Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估体外超高能量角膜交联(ECO-CAIRS)在模拟角膜同种异体基质内环段制备的实验模型中对猪角膜基质环段脱水和再水化行为的影响。瑞士苏黎世ELZA研究所。从新鲜摘除的猪角膜(n=48)制备角膜环段(每角膜两个),随机分为三组:对照组(无CXL,Jerky技术)、30 J/cm²体外超高能量CXL组和60 J/cm²体外超高能量CXL组(每组n=32)。去除上皮并制备环段后,对照组环段浸泡于平衡盐溶液(BSS)中,实验组环段浸泡于核黄素溶液(Ribo-Ker,EMAGine AG,瑞士楚格)中10分钟。随后每组均经历总计45分钟的脱水期,其中CXL处理组包括UV-A照射和等待阶段,之后使用BSS进行10分钟的再水化阶段。通过校准成像在基线、脱水后和再水化后测量环段厚度。各组间基线结构厚度值无显著差异。与对照组相比,两个CXL处理组均表现出显著更大的脱水程度(p<0.01)和减少的再水化(p<0.01)。两个CXL处理组之间未发现显著差异。超高能量交联增强了环段脱水并减缓了再水化。ECO-CAIRS有效调节角膜环段的脱水和再水化,这可能改善手术中的操作和植入特性。这些发现支持CXL在CAIRS手术中的潜在临床获益。需要进一步的体内研究以确认长期行为和生物力学影响。

Abstract

To evaluate the effects of extracorporeal ultra-high-fluence corneal cross-linking (ECO-CAIRS) on the dehydration and rehydration behavior of porcine corneal stromal ring segments in an experimental model simulating the preparation of corneal allogenic intrastromal ring segments. ELZA Institute, Zurich, Switzerland. Corneal ring segments (two per cornea) were prepared from freshly enucleated porcine corneas (n=48) and randomly divided into three groups: controls (no CXL, Jerky technique), extracorporeal ultra-high-fluence CXL at 30 J/cm2, and 60 J/cm2 (n=32 each). After epithelial removal and ring preparation, segments in the control group were soaked in balanced salt solution (BSS), while those in the experimental groups were soaked in riboflavin solution (Ribo-Ker, EMAGine AG, Zug, Switzerland) for 10 minutes. Each group subsequently underwent a total dehydration period of 45 minutes, which included both UV-A irradiation and waiting phases for the CXL-treated groups, followed by a 10-minute rehydration phase using BSS. Segment thickness was measured by calibrated imaging at baseline, after dehydration, and after rehydration. Baseline structural thickness values did not differ significantly between groups. Both CXL-treated groups demonstrated significantly greater dehydration (p<0.01) and reduced rehydration (p<0.01) when compared to controls. No significant differences were found between the two CXL-treated groups. Ultra-high-fluence cross-linking enhanced segment dehydration and slowed rehydration. ECO-CAIRS effectively modulates the dehydration and rehydration of corneal ring segments, which may improve handling and implantation characteristics during surgery. These findings support the potential clinical benefit of CXL in CAIRS procedures. Further in vivo studies are required to confirm long-term behavior and biomechanical impact.

如何引用

AMA

Léonard Kollros, M Enes Aydemir, Craig Boote, Keith M Meek, Sally Hayes, Mark Hillen, et al. Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).. Journal of cataract and refractive surgery. 2026; doi:10.1097/j.jcrs.0000000000002015.

APA

Léonard Kollros, M Enes Aydemir, Craig Boote, Keith M Meek, Sally Hayes, Mark Hillen, et al (2026). Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).. Journal of cataract and refractive surgery. https://doi.org/10.1097/j.jcrs.0000000000002015

GB/T 7714

Léonard Kollros, M Enes Aydemir, Craig Boote, Keith M Meek, Sally Hayes, Mark Hillen, et al. Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).[J]. Journal of cataract and refractive surgery, 2026 doi:10.1097/j.jcrs.0000000000002015.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of cataract and refractive surgery 的其他文献