选择性激光装置在白色膨胀性白内障中制作中心囊切开术的有效性和安全性:国际多中心研究(LC-WIC研究)

Efficacy and safety of aselective laser device to create centred capsulotomies in white intumescent cataracts: international multicentre study (LC-WIC study).

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估一种选择性激光设备(CAPSULaser,EXCEL-LENS,美国加利福尼亚州)在白色膨胀性白内障眼中创建居中且圆形前囊切开的有效性和安全性。这是一项国际多中心研究,涵盖英国、保加利亚、印度和沙特阿拉伯的五个临床中心。前瞻性、多中心介入性队列研究。共招募了91名受试者的93只白色膨胀性白内障眼,此前经眼前节OCT(AS-OCT)确认存在提示晶状体内压升高的晶状体内液体积聚。在所有病例中,于超声乳化术前,通过使用定制的0.4%台盼蓝溶液对前囊进行染色来实施选择性激光囊切开术(SLC)。囊切开直径设定为5.5 mm。受试者在术后1天、1周、1个月和3个月进行随访。在所有病例中,囊切开均成功创建。未观察到术中并发症。术后3个月时,平均囊切开直径测量为5.3 mm(范围:5.2至5.5 mm)。在3个月随访期间未观察到囊膜闭锁病例。在所有病例中,视力从术前光感提高至术后平均裸眼远视力(UDVA)为0.28 LogMAR(范围:0.0至1.0)。在这一系列膨胀性白内障眼中使用SLC实现了尺寸一致且居中良好的囊膜开口。无并发症发生。这些结果凸显了使用选择性激光囊切开术在白色膨胀性白内障中创建前囊切开的精确性和安全性。

Abstract

To evaluate the efficacy and safety of a selective laser device (CAPSULaser, EXCEL- LENS, CA, USA) to create centred and circular anterior capsulotomies in eyes with white intumescent cataracts. International, multicentre, study across five clinical sites in the United Kingdom, Bulgaria, India and Saudi Arabia. Prospective, multicentre interventional cohort study. A total of 93 eyes of 91 subjects with white intumescent cataracts were recruited after anterior segment OCT (AS-OCT) established the presence of intralenticular fluid pockets indicative of raised intralenticular pressure. In all cases, prior to phacoemulsification, selective laser capsulotomy (SLC) was performed by staining the anterior capsule with a customised 0.4 % trypan blue solution. Capsulotomies were created with a diameter of 5.5 mm. Subjects were followed up at one day, one week, one and three months postoperatively. In all cases, the capsulotomy was successfully created. No intraoperative complications were observed. At 3 months postoperatively the mean capsulotomy diameter measured 5.3 mm (range: 5.2 to 5.5 mm). No cases of capsular phimosis were observed during the three months follow-up. In all cases, visual acuity improved from preoperative light perception to mean postoperative uncorrected distance visual acuity (UDVA) of 0.28 LogMAR (range: 0.0 to 1.0). The use of SLC in this series of eyes with intumescent cataracts achieved consistently sized and well-centred capsular openings. There were no complications. These results highlight the precision and safety of using selective laser capsulotomy for creating anterior capsulotomies in white intumescent cataracts.

如何引用

AMA

Sathish Srinivasan, Jai Kelkar, Aditya Kelkar, Hassan Khaled, Christina Grupcheva, Alek Topov, et al. Efficacy and safety of aselective laser device to create centred capsulotomies in white intumescent cataracts: international multicentre study (LC-WIC study).. Journal of cataract and refractive surgery. 2026; doi:10.1097/j.jcrs.0000000000001996.

APA

Sathish Srinivasan, Jai Kelkar, Aditya Kelkar, Hassan Khaled, Christina Grupcheva, Alek Topov, et al (2026). Efficacy and safety of aselective laser device to create centred capsulotomies in white intumescent cataracts: international multicentre study (LC-WIC study).. Journal of cataract and refractive surgery. https://doi.org/10.1097/j.jcrs.0000000000001996

GB/T 7714

Sathish Srinivasan, Jai Kelkar, Aditya Kelkar, Hassan Khaled, Christina Grupcheva, Alek Topov, et al. Efficacy and safety of aselective laser device to create centred capsulotomies in white intumescent cataracts: international multicentre study (LC-WIC study).[J]. Journal of cataract and refractive surgery, 2026 doi:10.1097/j.jcrs.0000000000001996.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of cataract and refractive surgery 的其他文献