940 nm半导体激光辅助机械清创术对种植体周围炎治疗中S100A8水平和临床参数的影响
Effect of 940 nm diode laser adjunct to mechanical debridement on S100A8 levels and clinical parameters in peri-implantitis treatment.
Effect of 940 nm diode laser adjunct to mechanical debridement on S100A8 levels and clinical parameters in peri-implantitis treatment.
本研究旨在比较二极管激光及联合治疗方案在机械清创基础上辅助应用于种植体周围炎治疗时,对临床牙周参数及种植体周围沟液(PISF)中S100A8水平的效果。共39例诊断为种植体周围炎的患者根据所采用的治疗方案分为三组:机械清创组、二极管激光组和联合治疗组。在基线和第4周、第12周记录探诊深度、临床附着水平、改良菌斑指数、牙龈指数及PISF体积测量值。采用ELISA法测定PISF样本中S100A8水平。在12周随访期间,所有组别的临床参数较基线均有统计学显著改善(p < 0.05)。组间比较显示,联合治疗组在改良菌斑指数(mPI)和牙龈指数(GI)方面下降最为显著,具有统计学优势(p < 0.001)。尽管各组在探诊深度和临床附着获得方面无统计学显著差异,但联合治疗组观察到最大的数值改善。尽管临床指标有所改善,各组间及随时间变化的总S100A8水平均未检测到显著变化(p > 0.05)。机械清创联合二极管激光治疗种植体周围炎在减轻炎症临床体征方面优于任一方法单独使用。然而,S100A8水平与临床改善之间缺乏相关性,提示该生物标志物在短期治疗随访中可能不敏感。
The aim of this study was to compare the effectiveness of diode laser and combined treatment protocols, applied in addition to mechanical debridement, in the treatment of peri-implantitis on clinical periodontal parameters and S100A8 levels in peri-implant sulcus fluid (PISF). A total of 39 patients diagnosed with peri-implantitis were divided into three groups based on the treatment protocols used: Mechanical Debridement, Diode Laser, and Combined Treatment. Probing depth, clinical attachment level, modified plaque index, gingival index, and PISF volume measurements were recorded at baseline and at weeks 4 and 12. S100A8 levels in PISF samples were measured by ELISA. During the 12-week follow-up period, statistically significant improvements in clinical parameters were observed in all groups compared with baseline (p < 0.05). In the intergroup comparison, the most significant decrease and statistical superiority in mPI and GI values were observed in the combined treatment group (p < 0.001). Although there was no statistically significant difference among the groups in probing depth and clinical attachment gain, the greatest numerical improvement was observed in the combined group. Despite clinical improvement, no significant change in total S100A8 levels was detected between groups or over time (p > 0.05). The combined use of mechanical debridement and a diode laser in the treatment of peri-implantitis is more effective at reducing clinical signs of inflammation than either method used alone. However, the lack of correlation between S100A8 levels and clinical improvement suggests that this biomarker may not be sensitive in short-term follow-up of treatment.
Akif Nalbant, Hatice Ebru Olgun, Meltem Hendek, Osman Çağlayan. Effect of 940 nm diode laser adjunct to mechanical debridement on S100A8 levels and clinical parameters in peri-implantitis treatment.. Lasers in medical science. 2026; doi:10.1007/s10103-026-04925-1.
Akif Nalbant, Hatice Ebru Olgun, Meltem Hendek, Osman Çağlayan (2026). Effect of 940 nm diode laser adjunct to mechanical debridement on S100A8 levels and clinical parameters in peri-implantitis treatment.. Lasers in medical science. https://doi.org/10.1007/s10103-026-04925-1
Akif Nalbant, Hatice Ebru Olgun, Meltem Hendek, Osman Çağlayan. Effect of 940 nm diode laser adjunct to mechanical debridement on S100A8 levels and clinical parameters in peri-implantitis treatment.[J]. Lasers in medical science, 2026 doi:10.1007/s10103-026-04925-1.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出