无PCR级联CRISPR-Cas13a比色平台(CLAMP),用于非侵入性基于miRNA的变应性鼻炎过敏原特异性亚型

PCR-free cascaded CRISPR-Cas13a colorimetric platform (CLAMP) for non-invasive miRNA-based allergen-specific subtyping of allergic rhinitis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

准确识别致病过敏原对于过敏性鼻炎(AR)的个性化管理至关重要,然而现有方法往往难以区分临床相关性与致敏状态,尤其是在多重致敏患者中。为解决这一问题,我们开发了CLAMP(级联CRISPR-Cas13a LAMP比色法检测平台),该平台利用单一Cas13a/crRNA复合物启动简化的CRISPR级联扩增,实现加样后无需开盖的一锅两步法检测。该检测采用基于CIELAB ΔE的比色读出方式,仅需简单热源即可实现低设备依赖的定量生物标志物分析。CLAMP的检测限达到1.15 × 10 M,特异性优异,周转时间低于60分钟。在利用200个过敏原特异性AR小鼠模型的鼻灌洗液进行的临床前验证中,CLAMP通过多重miRNA检测实现了基于过敏原的AR分型,在区分主要过敏原亚型方面达到91.5%的准确率。这一低成本、非侵入性平台在快速过敏原分类及未来向AR个性化免疫治疗转化方面具有强大潜力。

Abstract

Accurate identification of causative allergens is critical for personalized management of allergic rhinitis (AR), yet current methods often fail to distinguish clinical relevance from sensitization, particularly in polysensitized patients. To address this, we developed CLAMP (Cascaded CRISPR-Cas13a LAMP Colorimetric Assay), a platform that leverages a single Cas13a/crRNA complex to initiate a simplified CRISPR cascade amplification, enabling one-pot two-step detection without tube opening after sample addition. The assay employs a colorimetric readout based on CIELAB ΔE, allowing quantitative biomarker analysis with minimal equipment, requiring only a simple heat source. CLAMP achieves a detection limit of 1.15 × 10 M with excellent specificity and a turnaround time under 60 min. In preclinical validation using nasal lavage fluid from 200 allergen-specific AR mouse models, CLAMP enabled allergen-based AR classification via multiplex miRNA detection, achieving 91.5% accuracy in distinguishing major allergen subtypes. This low-cost, non-invasive platform holds strong potential for rapid allergen classification and future translation toward personalized immunotherapy in AR.

如何引用

AMA

Youyang Wan, Qian Hu, Jiachen Zhu, Qi Wei Oung, Chia Hau Lee, Hongfeng Han, et al. PCR-free cascaded CRISPR-Cas13a colorimetric platform (CLAMP) for non-invasive miRNA-based allergen-specific subtyping of allergic rhinitis.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.118773.

APA

Youyang Wan, Qian Hu, Jiachen Zhu, Qi Wei Oung, Chia Hau Lee, Hongfeng Han, et al (2026). PCR-free cascaded CRISPR-Cas13a colorimetric platform (CLAMP) for non-invasive miRNA-based allergen-specific subtyping of allergic rhinitis.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.118773

GB/T 7714

Youyang Wan, Qian Hu, Jiachen Zhu, Qi Wei Oung, Chia Hau Lee, Hongfeng Han, et al. PCR-free cascaded CRISPR-Cas13a colorimetric platform (CLAMP) for non-invasive miRNA-based allergen-specific subtyping of allergic rhinitis.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.118773.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献