低剂量颈动脉CT血管造影(CTA)用于颈动脉斑块定量评估的可行性

Feasibility of low-dose carotid CT angiography (CTA) for quantitative carotid plaque evaluation.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估低剂量颈动脉CT血管成像(CTA)用于颈动脉斑块特征定量分析的可行性和准确性。在这项前瞻性研究中,颈动脉粥样硬化患者在同一天接受低剂量和常规剂量颈动脉CTA检查。每位患者接受三种低剂量方案之一——80 kVp/40 mL(A亚组)、60 kVp/40 mL(B亚组)或60 kVp/20 mL(C亚组)——并以常规方案(100 kVp/40 mL)作为参考标准。使用自动化软件进行定量斑块分析,包括总斑块体积、各斑块成分体积(钙化、纤维、纤维脂质和脂质)以及狭窄相关测量指标。记录并比较辐射剂量指标,包括CTDI、剂量长度乘积(DLP)和有效剂量(ED)。在低剂量与常规剂量扫描之间进行个体内比较。共分析154个斑块(来自67例患者)。与常规剂量CTA相比,低剂量方案显著降低了辐射暴露(ED:0.33 ± 0.15 mSv vs. 0.98 ± 0.10 mSv,p < 0.001),相当于约减少66%。低剂量与常规剂量CTA在总斑块体积、斑块成分体积、直径狭窄程度或最大面积狭窄程度方面均未观察到显著差异(均p > 0.05)。亚组分析表明,与常规剂量组相比,A、B和C亚组的定量斑块测量结果保持稳定(均p > 0.05)。在不同斑块类型(钙化、混合和非钙化)中,低剂量与常规剂量CTA对斑块成分的定量评估保持一致。使用60 kVp的低剂量CTA能够在大幅降低辐射剂量的同时,保持对颈动脉斑块特征的可靠定量评估。

Abstract

To evaluate the feasibility and accuracy of low-dose carotid CT angiography (CTA) for quantitative assessment of carotid plaque characteristics. In this prospective study, patients with carotid atherosclerosis underwent both low- and conventional-dose carotid CTA on the same day. Each patient received one of three low-dose protocols-80 kVp/40 mL (subgroup A), 60 kVp/40 mL (B), or 60 kVp/20 mL (C)-along with the conventional protocol (100 kVp/40 mL) as the reference standard. Quantitative plaque analysis was performed using automated software, including total plaque volume, volume of each plaque component (calcification, fiber, fibrolipid, and lipid), and stenosis-related measurements. Radiation dose metrics, including CTDI, dose-length product (DLP), and effective dose (ED), were recorded and compared. Intra-individual comparisons were conducted between low-dose and conventional-dose scans. A total of 154 plaques (from 67 patients) were analyzed. Compared with conventional-dose CTA, low-dose protocols significantly reduced radiation exposure (ED: 0.33 ± 0.15 mSv vs. 0.98 ± 0.10 mSv, p < 0.001), corresponding to a reduction of approximately 66 %. No significant differences were observed between low-dose and conventional-dose CTA in total plaque volume, plaque component volumes, diameter stenosis, or maximal area stenosis (all p > 0.05). Subgroup analysis demonstrated that quantitative plaque measurements remained stable across subgroups A, B, and C compared with the conventional-dose group (all p > 0.05). Across different plaque types (calcified, mixed, and non-calcified), quantitative assessment of plaque components remained consistent between low-dose and conventional-dose CTA. Low-dose CTA using 60 kVp enables substantial radiation dose reduction while preserving reliable quantitative assessment of carotid plaque characteristics.

如何引用

AMA

Min Jie Zhao, Chang Sheng Zhou, Jian Rui Li, Li Qi, Ling Yan Zhang, Jian Chen Qi, et al. Feasibility of low-dose carotid CT angiography (CTA) for quantitative carotid plaque evaluation.. European journal of radiology. 2026; doi:10.1016/j.ejrad.2026.112993.

APA

Min Jie Zhao, Chang Sheng Zhou, Jian Rui Li, Li Qi, Ling Yan Zhang, Jian Chen Qi, et al (2026). Feasibility of low-dose carotid CT angiography (CTA) for quantitative carotid plaque evaluation.. European journal of radiology. https://doi.org/10.1016/j.ejrad.2026.112993

GB/T 7714

Min Jie Zhao, Chang Sheng Zhou, Jian Rui Li, Li Qi, Ling Yan Zhang, Jian Chen Qi, et al. Feasibility of low-dose carotid CT angiography (CTA) for quantitative carotid plaque evaluation.[J]. European journal of radiology, 2026 doi:10.1016/j.ejrad.2026.112993.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

European journal of radiology 的其他文献