心脏光子计数CT中的人工智能去噪:在保持临床互换性的同时减轻BMI相关的噪声退化

Artificial intelligence denoising in cardiac photon-counting CT: mitigating BMI-related noise degradation while maintaining clinical interchangeability.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估基于人工智能的去噪(AID)算法能否在心脏光子计数探测器CT(PCD-CT)中有效减轻与体重指数(BMI)相关的噪声退化,同时与量子迭代重建(QIR)相比保持严格的定量诊断等效性和临床可互换性。这项回顾性研究纳入了100例在双源PCD-CT上接受非对比冠状动脉钙化(CAC)评分和对比增强冠状动脉CT血管造影(CCTA)的患者。图像分别使用标准QIR和PCD-CT加权的AID算法进行重建。由四名设盲的评分者评估主观图像质量。客观指标包括噪声幅度(噪声功率谱)和空间分辨率(边缘上升距离)。采用频率学派广义估计方程(GEE)评估重建效应及BMI交互作用。使用贝叶斯实际等效区域(ROPE)评估临床可互换性(Agatston评分、冠状动脉年龄、CAD-RADS和斑块特征)。AID显著改善了主观图像质量,并使CAC中的总体噪声幅度降低约64%,CCTA中降低约78%(p<0.001)。GEE模型显示,AID稳健地减轻了BMI驱动的噪声升高,CAC中降低44%,CCTA中降低78%(两者交互作用p<0.001)。噪声纹理在CCTA数据集中保持稳定,但在CAC数据集中表现为平滑化。然而,空间分辨率得以保留,并在不同患者体型中保持稳定。ROPE分析证明QIR与AID之间具有严格的诊断等效性,对于连续Agatston评分、分类CAD-RADS严重程度分级以及特定冠状动脉斑块成分,实际等效性的概率接近确定(>0.999)。PCD-CT加权的AID算法改善了CAC和CCTA的主观及客观图像质量,同时与QIR相比保持了诊断等效性和工作流程效率。

Abstract

To evaluate whether an artificial intelligence-based denoising (AID) algorithm can effectively attenuate body mass index (BMI)-related noise degradation in cardiac photon-counting detector CT (PCD-CT) while maintaining strict quantitative diagnostic equivalence and clinical interchangeability compared with quantum iterative reconstruction (QIR). This retrospective study included 100 patients undergoing non-contrast coronary artery calcium (CAC) scoring and contrast-enhanced coronary CT angiography (CCTA) on a dual-source PCD-CT. Images were reconstructed using standard QIR and a PCD-CT-weighted AID algorithm. Subjective image quality was assessed by four blinded raters. Objective metrics included noise magnitude (noise power spectrum) and spatial resolution (edge rise distance). Frequentist generalized estimating equations (GEE) evaluated reconstruction effects and BMI interactions. Clinical interchangeability (Agatston scoring, coronary age, CAD-RADS, and plaque characterization) was assessed using Bayesian regions of practical equivalence (ROPE). AID significantly improved subjective image quality and reduced overall noise magnitude by approximately 64 % in CAC and 78 % in CCTA (p<0.001). GEE models revealed that AID robustly attenuated BMI-driven noise escalation by 44 % (CAC) and 78 % (CCTA, p<0.001 for interactions in both). Noise texture was stable in CCTA datasets, but revealed smoothening in CAC datasets. However, spatial resolution was preserved and remained stable across varying patient habitus. ROPE analysis proved strict diagnostic equivalence between QIR and AID, yielding near-certain probabilities (>0.999) of practical equivalence for continuous Agatston scores, categorical CAD-RADS severity classification, and specific coronary plaque composition. The PCD-CT-weighted AID algorithm improves subjective and objective image quality in both CAC and CCTA, while maintaining diagnostic equivalence and workflow efficiency compared to QIR.

如何引用

AMA

Lisa Urban, Josephine Berger, Jan M Brendel, Judith Herrmann, Patrick Krumm, Konstantin Nikolaou, et al. Artificial intelligence denoising in cardiac photon-counting CT: mitigating BMI-related noise degradation while maintaining clinical interchangeability.. European journal of radiology. 2026; doi:10.1016/j.ejrad.2026.112921.

APA

Lisa Urban, Josephine Berger, Jan M Brendel, Judith Herrmann, Patrick Krumm, Konstantin Nikolaou, et al (2026). Artificial intelligence denoising in cardiac photon-counting CT: mitigating BMI-related noise degradation while maintaining clinical interchangeability.. European journal of radiology. https://doi.org/10.1016/j.ejrad.2026.112921

GB/T 7714

Lisa Urban, Josephine Berger, Jan M Brendel, Judith Herrmann, Patrick Krumm, Konstantin Nikolaou, et al. Artificial intelligence denoising in cardiac photon-counting CT: mitigating BMI-related noise degradation while maintaining clinical interchangeability.[J]. European journal of radiology, 2026 doi:10.1016/j.ejrad.2026.112921.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

European journal of radiology 的其他文献