胶质母细胞瘤的低分割MR引导放射治疗:使用MR直线加速器的机构在线自适应工作流程

Hypofractionated MR-guided radiotherapy for glioblastoma: Institutional online adaptive workflow using MR-linac.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

描述在新诊断的胶质母细胞瘤(GBM)患者中,使用MR-Linac系统实施大分割磁共振引导放射治疗(MRgRT)的可行性及临床实施情况,重点关注自适应计划、肿瘤体积动态变化和工作流程效率。一名74岁男性GBM患者接受了全切除术,随后接受MRgRT。治疗计划采用高分辨率MR与CT融合。在线自适应通过“adapt-to-shape”和“adapt-to-position”方案实施。靶区体积利用配准的术后影像进行勾画。记录体积变化和治疗工作流程指标。患者完成了15次大分割放疗(40.05 Gy,2.67 Gy/次),无延迟或并发症。自适应MRgRT实现了精确的靶区覆盖,并考虑了显著的解剖学变化。大体肿瘤体积(GTV)从术后32.25 cc增加至第6次分割时的69.55 cc(+112.32%),CTV和PTV相应增加。T2/FLAIR异常范围也扩大至最高+83.67%。每次分割的中位治疗时间为27.1分钟(范围:19.3至68.5),影像采集、勾画和计划制定是自适应分割中治疗时间延长的主要贡献因素。治疗耐受良好,仅报告2级乏力。本病例说明了MRgRT用于GBM的可行性及潜在临床价值。实时自适应计划使临床医生能够对肿瘤和瘤腔变化作出动态响应,有可能改善靶区覆盖并降低毒性。需要进一步研究评估其对结局的影响,并探索将功能成像整合到自适应工作流程中。

Abstract

To describe the feasibility and clinical implementation of hypofractionated Magnetic Resonance-guided Radiotherapy (MRgRT) using an MR-Linac system in a newly diagnosed glioblastoma (GBM) patient, with a focus on adaptive planning, tumor volume dynamics, and workflow efficiency. A 74-year-old male with GBM underwent gross total resection followed by MRgRT. Treatment planning used high-resolution MR and CT fusion. Online adaptation was performed using "adapt-to-shape" and "adapt-to-position" protocols. Target volumes were delineated using co-registered postoperative imaging. Volumetric changes and treatment workflow metrics were recorded. The patient completed 15 fractions of hypofractionated RT (40.05 Gy in 2.67 Gy/fraction) without delays or complications. Adaptive MRgRT enabled precise target coverage and accounted for significant anatomical changes. The gross tumor volume (GTV) increased from 32.25 cc postoperatively to 69.55 cc at fraction 6 (+112.32%), with corresponding increases in CTV and PTV. T2/FLAIR abnormalities also expanded by up to +83.67%. Median treatment time per fraction was 27.1 minutes (range: 19.3 to 68.5), with imaging, contouring, and planning contributing most to extended durations during adaptive fractions. Treatment was well tolerated, with only grade 2 asthenia reported. This case illustrates the feasibility and potential clinical value of MRgRT for GBM. Real-time adaptive planning enables clinicians to respond dynamically to tumor and cavity changes, potentially improving target coverage and reducing toxicity. Further studies are warranted to assess its impact on outcomes and to explore the integration of functional imaging into adaptive workflows.

如何引用

AMA

Alonso La Rosa, Giorgia Yang, Beatriz Moreno, Laura Zaragoza, Inmaculada Navarro, Concepción Huertas, et al. Hypofractionated MR-guided radiotherapy for glioblastoma: Institutional online adaptive workflow using MR-linac.. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2026; doi:10.1016/j.meddos.2026.04.007.

APA

Alonso La Rosa, Giorgia Yang, Beatriz Moreno, Laura Zaragoza, Inmaculada Navarro, Concepción Huertas, et al (2026). Hypofractionated MR-guided radiotherapy for glioblastoma: Institutional online adaptive workflow using MR-linac.. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. https://doi.org/10.1016/j.meddos.2026.04.007

GB/T 7714

Alonso La Rosa, Giorgia Yang, Beatriz Moreno, Laura Zaragoza, Inmaculada Navarro, Concepción Huertas, et al. Hypofractionated MR-guided radiotherapy for glioblastoma: Institutional online adaptive workflow using MR-linac.[J]. Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2026 doi:10.1016/j.meddos.2026.04.007.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI