使用深度学习评估高BMI患者四重低冠状动脉CT血管造影的图像质量和诊断性能

Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

探讨在深度学习图像重建(DLIR)辅助下,对高体重指数(BMI)受试者行冠状动脉计算机断层摄影血管造影(CCTA)时采用四低方案的可行性。本前瞻性研究纳入180名受试者(BMI≥25 kg/m²)。受试者被随机分为三组:标准剂量(SD)组采用100 kVp管电压,结合自适应统计迭代重建(ASIR-V 50%),对比剂(CM)给药方案为碘负荷245 mgI/kg(碘海醇,350 mgI/mL),注射时间10 s;实验组采用80 kVp管电压和DLIR-H进行成像,碘负荷128 mgI/kg,注射时间7 s,其中使用350 mgI/mL碘海醇者为三低(TL)组,使用320 mgI/mL碘克沙醇者为四低(QL)组。定量图像质量评估包括血管衰减、图像噪声、信噪比(SNR)和对比噪声比(CNR),同时评估定性图像质量和诊断效能。与SD组相比,TL组辐射剂量降低29.4%,对比剂用量减少47.5%,对比剂注射速率降低23.5%;QL组辐射剂量降低32.5%,对比剂用量减少41.5%,对比剂注射速率降低14.5%,对比剂浓度降低9%。QL组和TL组的图像噪声均显著低于SD组(均p < 0.001)。总体而言,TL组和QL组的SNR、CNR及定性图像质量均优于SD组(p < 0.05)。QL组维持了狭窄诊断效能(均p > 0.05)。与SD方案相比,TL和QL CCTA方案显示出等效或更优的图像质量和诊断准确性,可能成为高BMI患者降低辐射剂量和对比剂用量的有效替代方案。

Abstract

To examine the feasibility of a quadruple-low protocol in coronary computed tomography angiography (CCTA) assisted by the deep learning image reconstruction (DLIR) for participants with high body mass index (BMI). This prospective study involved 180 participants (BMI of ≥ 25 kg/m). Participants were randomly assigned to three groups: the standard-dose (SD) group in 100 kVp with adaptive statistical iterative reconstruction (ASIR-V 50%) using contrast media (CM) administration at an iodine load of 245 mgI/kg (Iohexol, 350 mgI/mL) with a 10 s injection time; the experimental group underwent imaging with 80 kVp and DLIR-H, using an iodine load of 128 mgI/kg with a 7 s injection time, representing the triple-low (TL) with 350 mgI/mL Iohexol and quadruple-low (QL) groups with 320 mgI/mL Iodixanol. Quantitative image quality evaluations included vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), while qualitative image quality and diagnostic performance were also assessed. Compared to the SD group, the TL group achieved reductions of 29.4% in radiation dose, 47.5% in CM volume, and 23.5% in CM injection rate, while the QL group achieved reductions of 32.5% in radiation dose, 41.5% in CM volume, 14.5% in CM injection rate, and 9% in CM concentration. The image noise in the QL and TL groups were significantly lower than in the SD group (all p < 0.001). Overall, the SNR, CNR, and qualitative image quality of the TL and QL groups were superior to those of the SD group (p < 0.05). The QL group maintained the stenosis diagnostic performance (all p > 0.05). TL and QL CCTA protocols showed equivalent or superior image quality and diagnostic accuracy compared to the SD protocol and may serve as effective alternatives for reducing radiation dose and contrast media use in patients with high BMI.

如何引用

AMA

Ke Qi, Shumeng Li, Luotong Wang, Jiangtao Zhao, Xiaohui Wang, Ping Hou, et al. Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients.. Academic radiology. 2026; doi:10.1016/j.acra.2026.04.048.

APA

Ke Qi, Shumeng Li, Luotong Wang, Jiangtao Zhao, Xiaohui Wang, Ping Hou, et al (2026). Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients.. Academic radiology. https://doi.org/10.1016/j.acra.2026.04.048

GB/T 7714

Ke Qi, Shumeng Li, Luotong Wang, Jiangtao Zhao, Xiaohui Wang, Ping Hou, et al. Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients.[J]. Academic radiology, 2026 doi:10.1016/j.acra.2026.04.048.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Academic radiology 的其他文献