基于李代数约束配准的CBCT中基于梯度的刚性运动校正
Gradient-based rigid motion correction in CBCT via Lie algebra-constrained registration.
Gradient-based rigid motion correction in CBCT via Lie algebra-constrained registration.
低帧率平板探测器和机架设计限制了锥形束计算机断层扫描(CBCT)的扫描速度,使其在长时间扫描过程中更容易受到患者运动的影响。刚性运动会使预先确定的成像几何结构失效,导致图像质量下降。为确保诊断可靠性并支持下游任务,准确的运动估计及随后的运动补偿重建至关重要。本研究提出了一种基于可微分3D-2D配准的CBCT通用刚性运动校正框架。我们引入了一种符合刚性变换定义的李群流形约束运动建模方法,并解析推导了CBCT前向投影算子关于刚性运动参数的梯度。此外,我们揭示了运动损坏图像与真实图像之间的空间偏差关系,提出了一种运动估计约束以增强收敛性。与最先进方法的实验对比表明,我们的方法实现了更优的运动估计和图像恢复。即使在严重运动条件下,也能有效恢复解剖细节并显著减少刚性运动伪影。
Low-frame-rate flat-panel detector and gantry design limit Cone-beam computed tomography (CBCT) scanning speed, increasing susceptibility to patient motion during prolonged scanning. Rigid motion invalidates the predetermined imaging geometry, leading to degraded image quality. To ensure diagnostic reliability and support downstream tasks, accurate motion estimation and subsequent motion-compensated reconstruction are essential. This work presents a general rigid motion correction framework for CBCT using differentiable 3D-2D registration. We introduce a Lie group manifold-constrained motion modeling approach that conforms to the definition of rigid transformation and analytically derive the gradient of the CBCT forward projection operator with respect to rigid motion parameters. Furthermore, we identify the spatial deviation relationship between motion-corrupted and ground truth images, proposing a motion estimation constraint to enhance convergence. Experimental comparisons with state-of-the-art methods demonstrate that our method achieves superior motion estimation and image restoration. It effectively recovers anatomical details and substantially reduces rigid motion artifacts, even under severe motion conditions.
Haotao Jiang, Fawei He, Siman Huang, Yujian Zhang, Hong Wang, Jianhua Ma, et al. Gradient-based rigid motion correction in CBCT via Lie algebra-constrained registration.. Physics in medicine and biology. 2026; doi:10.1088/1361-6560/ae6e8a.
Haotao Jiang, Fawei He, Siman Huang, Yujian Zhang, Hong Wang, Jianhua Ma, et al (2026). Gradient-based rigid motion correction in CBCT via Lie algebra-constrained registration.. Physics in medicine and biology. https://doi.org/10.1088/1361-6560/ae6e8a
Haotao Jiang, Fawei He, Siman Huang, Yujian Zhang, Hong Wang, Jianhua Ma, et al. Gradient-based rigid motion correction in CBCT via Lie algebra-constrained registration.[J]. Physics in medicine and biology, 2026 doi:10.1088/1361-6560/ae6e8a.